Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sample-time modified

There are a few other surface-sensitive characterization techniques that also rely on the use of lasers. For instance surface-plasmon resonance (SPR) measurements have been used to follow changes in surface optical properties as a fiinction of time as the sample is modified by, for instance, adsorption processes [ ]. SPR has proven usefiil to image adsorption patterns on surfaces as well [59]. [Pg.1790]

To install the stochastic observer to Eq. (7), the linrar pr ction model is modified and this can give compensation for the currently calculatM pr cted output by incorporating the difference between the real output y, at present time and the predictoi ou mt obtained one sampling time before Yf-j. The modified prediction model is expressed as follows ... [Pg.863]

Fig. 1 illustrates the identification result, i.e., validation of identified model. The 4-level pseudo random signal is introduced to obtain the excited output signal which contains the sufficient information on process dynamics. With these exciting and excited data, L and Lu as well as state space model are oalcidated and on the basis of these matrices the modified output prediction model is constructed according to Eq. (8). To both mathematical model assum as plimt and identified model another 4-level pseudo random signal is introduced and then the corresponding outputs fiom both are compared as shown in Fig. 1. Based on the identified model, we design the controller and investigate its performance under the demand on changes in the set-points for the conversion and M . The sampling time, prediction and... Fig. 1 illustrates the identification result, i.e., validation of identified model. The 4-level pseudo random signal is introduced to obtain the excited output signal which contains the sufficient information on process dynamics. With these exciting and excited data, L and Lu as well as state space model are oalcidated and on the basis of these matrices the modified output prediction model is constructed according to Eq. (8). To both mathematical model assum as plimt and identified model another 4-level pseudo random signal is introduced and then the corresponding outputs fiom both are compared as shown in Fig. 1. Based on the identified model, we design the controller and investigate its performance under the demand on changes in the set-points for the conversion and M . The sampling time, prediction and...
Press ENTER then select USE TIME SETUP to continue. Note If you want to change the sample time or sample number you entered, select MODIFY SETUP. [Pg.18]

More generally, Walter et al. (2002) tested the spatial cross-correlation between weed species and several soil properties. Certain weeds were correlated with specific soil chemical properties (e.g. P, pH) however, other species did not show consistent correlation with soil types between fields and sampling times, and some were correlated with more than one soil property. The most consistent relationship was between weed density and clay content. This result suggests that weeds have different resource requirements and that modifying soil conditions to manage certain weeds may promote others. [Pg.71]

Samples of sand spiked with 36 nitroaromatic compounds, 19 haloethers, and 42 organochlorine pesticides, and a standard reference soil (certified for 13 polynuclear aromatic hydrocarbons, dibenzofuran, and pentachlorophenol) were extracted with supercritical carbon dioxide in a two- or four-vessel supercritical fluid extractor to establish the efficiency of the extraction and the degree of agreement of the parallel extraction recoveries. Furthermore, the many variables that influence the extraction process (e.g., flowrate, pressure, temperature, moisture content, cell volume, sample size, extraction time, modifier type, modifier volume, static versus dynamic extraction, volume of solvent in the collection vessel, and the use of glass beads to fill the void volume) were investigated. [Pg.182]

Figure 6. Modified variable sample time for steam pressure change from 110 to... Figure 6. Modified variable sample time for steam pressure change from 110 to...
Therefore, the longest relaxation time of a chain in a polydisperse sample is modified by a shift factor k defined by ... [Pg.126]

NS suspensions were sterilized by autoclaving. 300 pL of sterile NS solution of 10x10 NS/mL was added to 10 pL 4-MBA (1 mM) and incubated overnight at room temperature. Excess 4-MBA was washed off by careful recovery of NS from the reaction solution by centrifugation. The sample of modified NS was washed a further four times in ddH20. [Pg.53]

Select the COLLECT DATA option from the MAIN MENU. Select the TIME GRAPH option from the DATA COLLECTION menu. Enter 6 for the time between samples, in seconds. Enter 99 for the number of samples. Press ENTER. Select USE TIME SETUP to continue. If you want to change the number of samples or the time between samples, select MODIFY SETUP. Enter 0 for Ymin, enter 100 for Ymax, and enter 5 for Yscl Press ENTER on the calculator to begin collecting temperature readings. [Pg.813]

If there is a delay in the effects of inputs on the output by sampling times, Eq. 4.31 is modified as... [Pg.86]

Time-based introduction is better implemented automatically, i.e., without human intervention. In this mode, the sampler arm selects the sample, the carrier/wash and eventually the reagent solutions (Fig. 6.8) to be directed towards the manifold. The sampling time is the main parameter governing the volumes of these solutions introduced, which can also be modified by changing the aspiration rate in the fluid propulsion unit. This is usually an option in modem instmments. [Pg.219]

Dip and dry involves reading the crystal s frequency while dry in the air. It is exposed to a sample or modified in some way. After sufficient time, in which binding or immobilisation of a species is complete, the crystal is washed and dried. The frequency is recorded again in a dry state in the air. The change in frequency, from before and after modification, is propor-... [Pg.241]

Flue gas samples were taken over a 7 hour period for the 30 minutes residence time case and over a 2.5 hour period for the 15 minute case. These sampling times were chosen so that sufficient gas sample could be collected to demonstrate the required destruction efficiency. The flue gas sampling was conducted in accordance with a modified EPA Method 5 procedure and the ASME dioxin protocol (1). The samples were collected isokinetically at a single stack sampling point. At the conclu-... [Pg.316]

Ring, et al., (1998 and 1999) have used a time-dependent magnetic field and the combination of a static magnetic field in a direction perpendicular to that of a time-dependent field to create and manipulate novel coherences and to monitor the quantum beats associated with specifiable details of the time evolution of these coherences. The frequencies and decay rates of different classes of coherence (AMj = 2 and 1 polarization beats, AMj = 0 singlet triplet population beats) may be sampled and modified selectively. [Pg.433]


See other pages where Sample-time modified is mentioned: [Pg.3029]    [Pg.323]    [Pg.70]    [Pg.489]    [Pg.206]    [Pg.371]    [Pg.278]    [Pg.197]    [Pg.180]    [Pg.68]    [Pg.470]    [Pg.109]    [Pg.283]    [Pg.278]    [Pg.545]    [Pg.323]    [Pg.868]    [Pg.925]    [Pg.812]    [Pg.186]    [Pg.413]    [Pg.153]    [Pg.271]    [Pg.145]    [Pg.267]    [Pg.754]    [Pg.3029]    [Pg.165]    [Pg.284]    [Pg.1333]    [Pg.194]    [Pg.48]   
See also in sourсe #XX -- [ Pg.284 ]




SEARCH



Sample-time

Sampling time

© 2024 chempedia.info