Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Rigaku-Denki camera

The progress achieved is closely linked to the development of both powerful detectors and brilliant X-ray sources (synchrotron radiation, rotating anode). Such point-focus equipment has replaced older slit-focus equipment (Kratky camera, Rigaku-Denki camera) in many laboratories, and the next step of instrumental progress is already discernible. With the X-ray free electron laser (XFEL) it will become possible to study very fast processes like the structure relaxation of elastomers after the removal of mechanical load. [Pg.7]

In addition to point-focus apparatus there are scattering devices with an extremely elongated cross-section of the primary beam. Historically this geometry has been developed as a compromise between ideal collimation and insufficient scattering power. Their practical importance is decreasing as more powerful point-collimated sources become available. Kratky camera (Alexander [7], p. 107-110) and Rigaku-Denki camera (BaltA Vonk [22], p. 83) are the most frequent representatives of slit-focus devices. [Pg.57]

The SAXS intensity distribution was measured with a rotating anode x-ray generator (Rigaku Denki, Rotaflex, RTP 300 RC) operated at 40 kV and 100 mA. The x-ray source was monochrolmatized to CuK (A = 0.154 nm) radiation. The SAXS patterns were taken with a fine-focused x-ray source using a flat plate camera (Rigaku Denki, RU-lOO). In the measurement of the solution sample, we used a glass capillary (< = 2.0 mm Mark-Rohrchen Ltd.) as a holder vessel. [Pg.603]

X-ray diffraction patterns were recorded using a Searle toroidal focusing camera with nickel filtered CuKa radiation generated by a Rigaku-Denki rotating anode source. [Pg.184]

With slit collimation, higher resolution may be obtained with much less loss of intensity. Such cameras are, for example, of the Rigaku-Denki and Kratky type, the latter employing an ingenious U-bar collimating system which permits resolution up to several thousand angstroms. While slit cameras may not readily be used to characterise degrees of partial orientation, a compromise is possible with cameras of... [Pg.111]


See other pages where Rigaku-Denki camera is mentioned: [Pg.272]    [Pg.272]    [Pg.285]    [Pg.732]    [Pg.334]   
See also in sourсe #XX -- [ Pg.39 ]

See also in sourсe #XX -- [ Pg.39 ]




SEARCH



Camera

Camera, cameras

© 2024 chempedia.info