Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Report generation

AM 5 / s Fig. 10.11 Chromatographic trace with report including system suitability tests. 1  [Pg.205]

Giddings. Unified separation science. Wiley Interscience. Chichester (1991). [Pg.205]


Although less researched than the 2-position, modifications at the 6-position of intact penems have been reported. Generation of the dianion of the penem (52, R = CH ) using a strong base such as / -butyUithium or lithium diisopropylamide, followed by reaction with electrophiles yields 6-substituted 2-methylpenems in moderate yield (128). The enhanced acidity of the 6-proton in the bromopenem (88) [114409-16-4] h.a.s been exploited to prepare the... [Pg.13]

Facility Chemical or Waste Recordkeeping, Reporting, and Compliance Assistance (e.g., manifests, labels, report generation) ... [Pg.279]

Industrial Pollutant Monitoring for recordkeeping and report generation and Process Monitoring/Rcporting for process reports and other reports. Each requires 512K memory and lOMeg hard disk. [Pg.300]

SARATRAX irr Research institute, Maryland Technology Center Dr. Quon Y. Kwan Sr. Env. Engineer 4600 Forbes Blvd Lanham, MD 20706 (800) 4S8-1564 (301) 459-3711 Assists with delcrminalion of facility reporting responsibilities under Sections 301-303, 304, and 311-312. Assists with notification requirements and definitions of responsibilities. Maintains lists of chemicals, quantities, locations, and properties to assist with the preparation of Tier I and Tier 11 reports. Generates Form R. [Pg.304]

TOXIC ALERT HAZOX Corporation Daniel Fullerton P.O. Bo 637 Chadds Fort, PA 19317 (215) 358 990 (800) 558-6942 Incident management tool with some emergency planning capability. Modules for MSDS, incident documentation, inventory, and Tier l/ll report generation. [Pg.306]

The portable vibration analyzer incorporates a microprocessor that allows it to mathematically convert the electrical signal to acceleration per unit time, perform a TFT, and store the data. It can be programmed to generate alarms and displays of the data. The data stored by the analyzer can be downloaded to a personal or a more powerful computer to perform more sophisticated analyses, data storage and retrieval, and report generation. [Pg.669]

The host computer provides all of the data management, storage, report generation, and analysis capabilities of the predictive maintenance program. Therefore, care should... [Pg.807]

As a minimum the software program should provide automatic database management, automatic trending, automatic report generation and simplified diagnostics. As in... [Pg.807]

Automatic report generation Report generation will be an important part of the predictive maintenance program. Maximum flexibility in format and detail is important to program success. The system should be able to automatically generate reports a multiple levels of detail. As a minimum, the system should be able to report ... [Pg.808]

Using the Toolbox, Transform, and Identify functions, the analyst can perform many general analyses such as a Tg of a DSC run or the weight loss in a TGA run. For Instance, to identify a TGA weight loss the operator could draw two guide lines on the screen, use the Identify function to measure the displacement, and the report generator to output the displacement and units. [Pg.16]

This information is saved under any name desired by the user. It is thereafter accessible through the report generator. If the user frequently saves data, the variable names can be permanently stored and accessed from the identify setup data resource file. [Pg.18]

A generator is used for all reporting. Since set up and result information is stored in a Resource File by name, the report generator can scan this file and insert the values wherever the name appears in the user s template... [Pg.18]

An ampersand at the beginning of a line tells the report generator that this line is to be repeated for each file selected. In this way, multiple files can be merged into custom tables by selecting the files of interest, clicking on the report option, and choosing the appropriate template from a file selector box. [Pg.19]

The goals of flexibility without complication and minimum software maintenance were achieved largely through the use of data resource files, the report generator, and the transform utility. These features are invisible to the casual user who is content with the standard report form and transform setup provided him. The more advanced user, however, can easily access all data, customize reports, and perform unique transformations. [Pg.20]

Computers. A certain number of personal computers are necessary for report generation and regulatory submission preparation. In addition, these may be useful for record keeping, depending on the type of stability information system that the company chooses to use. Alternatively, if the information system is intended to be accessible (read only) to many users, it may be more efficient to develop a local area network of mini-computers. The size of the database will help determine the nature of the software/hardware configuration used for this function. [Pg.168]

Recently, Chiron introduced the System 340 platform that automates incubation, washing, reading, data processing, and report generation. It is anticipated that automation will dramatically reduce operator-to-operator differences while decreasing labor requirements. In one laboratory the average coefficient of variation was reduced 43% and the hands-on labor was reduced 39% with the automated... [Pg.211]

Figure 1, Instron report generated by stress program. ... Figure 1, Instron report generated by stress program. ...

See other pages where Report generation is mentioned: [Pg.349]    [Pg.517]    [Pg.520]    [Pg.773]    [Pg.302]    [Pg.132]    [Pg.810]    [Pg.20]    [Pg.294]    [Pg.58]    [Pg.62]    [Pg.241]    [Pg.295]    [Pg.606]    [Pg.611]    [Pg.621]    [Pg.1075]    [Pg.727]    [Pg.101]    [Pg.7]    [Pg.8]    [Pg.96]    [Pg.519]    [Pg.616]    [Pg.146]    [Pg.265]    [Pg.494]    [Pg.267]    [Pg.306]    [Pg.360]    [Pg.373]    [Pg.171]    [Pg.122]   
See also in sourсe #XX -- [ Pg.19 ]

See also in sourсe #XX -- [ Pg.126 , Pg.127 , Pg.131 ]




SEARCH



Computer report generation

High-pressure liquid chromatography report generation

Report Generation Review

Report generator

© 2024 chempedia.info