Refrigeration compressor

For refrigeration compressors Miscibility with the refrigeration fluids (including compressors with the new refrigeration fluids) Adapted composition... [Pg.284]

I hope my reaction success and I can run the 100 grams batch tomorow. Another difficultie is now water tap is at about 29 C (to distill), may be I ll use a refrigerator compressor, I think it will be enough to distill ketone at about 180 C. [Pg.79]

Alkylated aromatics are used as the base fluid ia engine oils, gear oils, hydrauHc fluids, and greases ia sub2ero appHcations. They also are used as the base fluid ia power transmission fluids and gas turbine, air compressor, and refrigeration compressor lubricants. [Pg.272]

There are various options for capacity control of reciprocating refrigeration compressors ... [Pg.1111]

A more detailed description of compressor performance is shown in the section on the refrigeration compressors. [Pg.1116]

Do you have two cars Then you have about 12 pumps with seals. And in your house, how many. sealed pumps do you have In the kitchen, mechanical seals are on the pump in the dishwasher, the blender, the refrigerator compressor, and the garbage disposal under the sink. Do you have a clothes washer There are two seals on the clothes washer. [Pg.180]

Compressor horsepower is best determined using the horsepower calculation in Chapter 6. For refrigeration compressors, the horsepower can he approximated another way that may prove to be simpler. The compressor horsepower per ton of refrigeration load depends upon the evaporator and eondenser temperatures. See the seetion titled Estimating Horsepower per Ton in Chapter 11. [Pg.225]

Dugas, J. R., Southcott, J. F. and Tran, B. X., Adaptation of a Propylene Refrigeration Compressor With Dry Gas Seals, Proceedings of the 20th Turbomachinery Symposium, Texas A M University, College Station, TX, 1991, pp. 57-61. [Pg.223]

Figure 11-21D. Helical rotors refrigerant compressors. (1) Cutaway of a 100-ton intermediate compressor. The intermediate Helirotor compressor has only three moving parts the two rotor assemblies and the capacity controlling slide valve. The general purpose Helirotor compressor has only four moving parts two rotor assemblies, the variable unloader valve, and the step unloader valve. Unlike reciprocating compressors, the Trane Helirotor compressor has no pistons, connecting rods, suction and discharge valves, or mechanical oil pump. Figure 11-21D. Helical rotors refrigerant compressors. (1) Cutaway of a 100-ton intermediate compressor. The intermediate Helirotor compressor has only three moving parts the two rotor assemblies and the capacity controlling slide valve. The general purpose Helirotor compressor has only four moving parts two rotor assemblies, the variable unloader valve, and the step unloader valve. Unlike reciprocating compressors, the Trane Helirotor compressor has no pistons, connecting rods, suction and discharge valves, or mechanical oil pump.
A refrigeration compressor and condenser on one chassis complete with controls. [Pg.437]

Refrigeration compressors are mechanical devices with component parts which slide together, so requiring lubrication to reduce friction, remove frictional heat and assist with gas sealing. [Pg.57]

Refrigeration compressors which will probably be used on flooded evaporators (R.717 and the larger machines generally) will be rated with the suction at saturated conditions, since there will be little or no superheat in practice. Compressors for dry expansion systems may be rated at a stated amount of superheat, commonly 8 K. [Pg.357]

Example The brine temperature is set at -30 °C I °C. The brine temperature has been for some time between -31 °C and -30.5 °C, It rises e. g. in 2 h from this range to -30 °C and -29.5 °C. Warning of this trend is helpful Either the pumping speed of the brine pump is reduced or the injection valve of the refrigerant has shifted or the refrigerant compressor has changed its capacity. [Pg.173]

The conditions of water vapor transport between the chamber and condenser, the condenser surface, the capacity of the refrigerant compressors and the vacuum pumping capacity, must all be the same (pro rata) for the product dried in the laboratory as in the plant to which the process will be transferred. [Pg.174]

Some common enclosures are small buildings or enclosures for utility air or process gas compressors, gas turbines, refrigeration compressors, process pumps, filters, additive systems, dust collectors, field instruments, etc. [Pg.237]

Let s say we have a centrifugal refrigeration compressor, driven by a motor. The motor is tripping off because of high amperage. Should we open or close the suction throttle valve shown in Fig. 22.2 Answer— close it. Of course, both the evaporator vapor outlet temperature and the process fluid outlet temperature will increase. But that is the price we pay for having too small a motor driver on the compressor. Does this mean that when our home air conditioner gets low on freon, our electric bill drops Correct. But the price we pay is a hot home. [Pg.295]


See other pages where Refrigeration compressor is mentioned: [Pg.276]    [Pg.245]    [Pg.1]    [Pg.5]    [Pg.1110]    [Pg.1167]    [Pg.183]    [Pg.108]    [Pg.194]    [Pg.198]    [Pg.457]    [Pg.24]    [Pg.996]    [Pg.366]    [Pg.643]    [Pg.876]    [Pg.876]    [Pg.31]    [Pg.344]    [Pg.506]    [Pg.1613]    [Pg.208]    [Pg.172]    [Pg.173]    [Pg.174]    [Pg.189]    [Pg.301]    [Pg.302]    [Pg.249]    [Pg.34]    [Pg.503]    [Pg.59]    [Pg.5]    [Pg.271]   