Reference electrodes storage

Other problems occur in the measurement of pH in unbuffered, low ionic strength media such as wet deposition (acid rain) and natural freshwaters (see Airpollution Groundwatermonitoring) (13). In these cases, studies have demonstrated that the principal sources of the measurement errors are associated with the performance of the reference electrode Hquid junction, changes in the sample pH during storage, and the nature of the standards used in caHbration. Considerable care must be exercised in all aspects of the measurement process to assure the quaHty of the pH values on these types of samples. [Pg.466]

In the cathodic protection of storage tanks, potentials should be measured in at least three places, i.e., at each end and at the top of the cover [16]. Widely different polarized areas arise due to the small distance which is normally the case between the impressed current anodes and the tank. Since such tanks are often buried under asphalt, it is recommended that permanent reference electrodes or fixed measuring points (plastic tubes under valve boxes) be installed. These should be located in areas not easily accessible to the cathodic protection current, for example between two tanks or between the tank wall and foundations. Since storage tanks usually have several anodes located near the tank, equalizing currents can flow between the differently loaded anodes on switching off the protection system and thus falsify the potential measurement. In such cases the anodes should be separated. [Pg.100]

Fuel cell polymer battery photoelectric cell capacitor Storage element liquid crystal display device electrochromic display device electrochemiluminescence device photoelectric transducer Biosensor ion sensor detector in HPLC and FIA gas sensor voltam-metric indicator electrode reference electrode... [Pg.137]

The modification of electrode surfaces with electroactive polymer films provides a means to control interfacial characteristics. With such a capability, one can envisage numerous possible applications, in areas as diverse as electronic devices, sensors, electrocatalysis, energy conversion and storage, electronic displays, and reference electrode systems [1, 2]. With these applications in view, a wide variety of electroactive polymeric materials have been investigated. These include both redox polymers (by which we imply polymers with discrete redox entities distributed along the polymer spine) and conducting polymers (by which we imply polymers with delocalised charge centres on the polymer spine). [Pg.490]

A scheme of electrochemical cell and electrode design is reported in (Fig. 1). The sensors can be obtained from Ecobioservices and Researches S.r.l. (Florence, Italy). A typical electrode modification formulation is reported in Note 1. Further explanations regarding electrode composition are reported in Note 2. Before use, the pseudo Ag reference electrode is oxidized using NaCIO 14% solution, in order to avoid the oxidation of the Ag pseudoreference by thiols during measurements. For storage conditions rrrNote 3. [Pg.122]

Fig. IIL2.8 Storage of a commercially available reference electrode... Fig. IIL2.8 Storage of a commercially available reference electrode...
If a reference electrode Ag, AgCI KCI 1 mol has been stored with its tip immersed in distilled water, then calibration would show that its potential after storage... [Pg.168]

The auxiliary and reference electrodes are removed from their anaerobic storage cell, the plugs are removed from the spectroelectrochemical cell, and the electrodes are quickly inserted into the spectroelectrochemical cell under positive argon pressure (the reference electrode needs to be standardized against ferri/ferrocyanide, either before the start of the titration or at the end of the experiment, depending on the experiment (see following text)). [Pg.5786]

The use of cadmium and zinc bars as reference electrodes ) had become an established practice in the storage battery industry by the time that Nernst was concerning himself with the problem of a standard. Ostwald ( ) also mentions that in earlier times amalgamated zinc in a concentrated zinc sulfate solution was used as a constant electrode and occasionally as a reference electrode but that its use posed some serious problems. [Pg.129]

A) Storage cell, accumulator (P) potentiometer (G) galvanometer (R) sensitivity reductor (L) lamp (S) scale (M) mercury reservoir (C) capillary (B) burette (R) reference electrode ... [Pg.150]

Electrodes A pH electrode consists of two half-cells an indicating electrode and a reference electrode. Most applications today use a combination electrode with both half-cells in one body. Over 90 percent of pH measurement problems are related to the improper use, storage, or selection of electrodes. [Pg.72]

On a supertanker, the initial current of 10 A may rise to over 1000 A during the course of its operational life. Modern ICCP ship designs usually place anodes in symmetrical dispositions, but in bulk carriers, there is a need for internal access and for cable-runs to be away from anodes and reference electrodes. This usually precludes electrodes from being sited external to storage tanks. Instead electronics are placed either well forward or well aft, where the adjacent machinery spaces provide convenient access to the various pieces of equipment (Fig. 13.6). There are several reasons why potentiostatic systems frequently fail to provide adequate protection [8] ... [Pg.530]


See other pages where Reference electrodes storage is mentioned: [Pg.472]    [Pg.235]    [Pg.292]    [Pg.603]    [Pg.81]    [Pg.81]    [Pg.585]    [Pg.309]    [Pg.53]    [Pg.437]    [Pg.121]    [Pg.232]    [Pg.176]    [Pg.307]    [Pg.98]    [Pg.4950]    [Pg.4951]    [Pg.336]    [Pg.5783]    [Pg.61]    [Pg.235]    [Pg.292]    [Pg.703]    [Pg.387]    [Pg.1]    [Pg.913]    [Pg.363]    [Pg.495]    [Pg.107]    [Pg.89]    [Pg.295]   
See also in sourсe #XX -- [ Pg.307 ]