Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Range Evaluations

Estimation of the volume of distribution in man may be carried out in a number of ways. These methods have recently been reviewed by Obach et al. [60], who carried out a wide-ranging evaluation of a large number of different ways of predicting the human pharmacokinetics of 50 compounds that entered development at Pfizer. One of the simplest methods was reported to be the most reliable. It is based on the assumption that the free-fraction of drug in the plasma in dog and human and... [Pg.145]

TABLE 7 Typical Parameters and Ranges Evaluated During Method Robustness... [Pg.208]

The "Mannich" adduct synthesized from the condensation of formaldehyde, 2-(methylamino)ethanol and poly-4-vinylphenol as shown in Structure I, has been evaluated as a function of molecular weight versus corrosion resistance as measured by salt spray and humidity tests on Bonderite 1000, an iron phosphate conversion coating. The molecular weight of the polymer was varied from approximately = 2,900 to 60,000. The corrosion resistance results were essentially equivalent over the molecular weight range evaluated. [Pg.209]

Yeager, K. Data-Base of Range Evaluated Improvised Explosives (D-BREIE) Phase I Ammonium Nitrate Based Explosives. EMRTC Report to TSWG, July 1999. [Pg.67]

Preliminary Preclinical First in man Refine dose ranging evaluation (Lab/Animal Dose range Tests)... [Pg.54]

Reasonable durability of the FGM layer between the SiC layer and the CCC was shown within the experimental range, evaluated. [Pg.468]

Stability experiments should mimic, as best possible, the conditions under which study samples will be collected, stored, and processed. It is necessary to evaluate the stability conditions with at least two concentrations that represent the lower and the higher concentration ranges. Evaluation of the stability samples should be conducted with a freshly prepared standard curve. On the contrary, the assay QCs (in-study batch QCs) may be from the batches stored frozen within the established stability, or prepared fresh. There is still ongoing discussion regarding this topic. In either situation, what is necessary is a sound scientific justification for evaluation of the stability samples. Another facet to this is the situation where altered matrices are used for standard curve and QC preparations in this case, stability samples must be prepared in the unaltered matrix. [Pg.101]

For collision energies within the thermal range, evaluation of equation (47) leads to the following general predictions (i) P, f is very small, especially where the duration of the collision is much longer than the vibrational period (ii) the probabilities of molecules losing two or more quanta are very much smaller than those for — 1 processes (iii) for harmonic oscillators and, to a good approximation, for real molecules, To compare the theoretical results with... [Pg.30]

Assuming steady-state mass transfer, organic-aqueous liquid interface immobilized in the membrane pores, solute partition coefficient constant over the concentration range evaluated and immiscibifity of the two liquids, global expressions for the overall mass transfer coefficients for hollow-fiber microporous membranes, based on the aqueous phase Eq. (3)) or on the organic phase (X ,Eq. (4)) can be derived [189]. [Pg.135]

L. Collision cross-section for hard spheres. The hard-sphere potential has no attractive part. We can retain much of the simplicity of the model but modify the potential, as shown in Problem D of Chapter 5, by adding to the repulsive part a square well of finite range. Evaluate the collision cross-section for this potential. As a first step, plot the effective potential. [Pg.69]

Usually, the ionic conductivity is much smaller than that of the electrons. To determine it, the convenient tool is the complex impedance technique, because it requires very small current (prevents heating) and very small ionic motion. The a.c. method is called electrochemical impedance spectroscopy (EIS) because the impedance spectrum measured in a wide frequency range evaluates the performance of batteries and characterizes the various elements such as electrode, electrolyte and electrolyte/electrode interface. First, let us consider the ionic conductivity in a solid electrolyte. The complex impedance due to the Li-motion is ... [Pg.531]

As shown in Figure 6-10, the 185 kWe requirement may be achieved if the compressor pressure ratio is slightly increased (2.04), It is also noted that reactor thermal rating, required radiator area, and reactor inlet temperature continue to benefit as compressor pressure ratio increases within the range evaluated... [Pg.176]

Sensitivities to the reactor outlet temperature are shown in Figure 6-16 for the off-design case. Within the temperature range evaluated the net etectncal output available for spaceship loads varies from 201.3 kWe to 219.6 kWe. Over this same range the reactor thernial power varies from 839 kWt to 874 kWl. [Pg.183]

Sensitivities to the effective sink temperature are shown in Figure 6-20. Within the sink temperature range evaluated, 4K to 300K. the net electrical output available for spaceship loads varies from 217.4 kWe to 153.1 kWe. The system no longer makes the required 185 kWe when the sink temperature exceeds 225K. Over the same sink temperature range, the reactor thermal power varies from 841 kWt to 828 kWt,... [Pg.187]

SEM and fracture results suggest that deformation mechanisms were only slightly diminished by weld procedme in the temperature range evaluated. [Pg.425]


See other pages where Range Evaluations is mentioned: [Pg.522]    [Pg.157]    [Pg.476]    [Pg.300]    [Pg.237]    [Pg.518]    [Pg.170]    [Pg.284]    [Pg.342]    [Pg.7]    [Pg.189]    [Pg.421]    [Pg.546]    [Pg.34]    [Pg.538]    [Pg.45]    [Pg.8]    [Pg.424]   
See also in sourсe #XX -- [ Pg.6 ]




SEARCH



Co-operative Programme for Monitoring and Evaluation of the Long-Range

Robustness testing ranges evaluated

© 2024 chempedia.info