Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Quasi-optical methods

In addition, the steric configuration can be obtained by Raney nickel desulfurization to optically active aliphatic acids of known con-figuration. 2 2 Combined with the quasi racemate method this... [Pg.21]

CD and ORD measurements are a useful tool in studying configuration and conformation. The configuration of optically active 4,4 -dicarboxy-2,2, 5,5 -tetramethyl-3,3 -biselenienyl (1, X = Se) relative to its thiophene analog (1, X = S), was determined by reducing both to the corresponding 4,4 -dihydroxymethyl derivatives (2), which could be related to each other by the quasi-racemate method and by circular dichroism studies.15 Compounds 1 have also been related to 3,3, 6,6 -tetramethyl-2,2 -diphenic acid (3), and it was found that the levorotatory form of 1 (X = Se, S) and the dextrorotatory form of 3 have the -configuration.16... [Pg.130]

METHODS BASED ON MEASURING OPTICAL ACTIVITY The isotopic quasi-racemate method (IQRM)... [Pg.234]

In order to actually cover 19 decades in frequency, dielectric spectroscopy makes use of different measurement techniques each working at its optimum in a particular frequency range. The techniques most commonly applied include time-domain spectroscopy, frequency response analysis, coaxial reflection and transmission methods, and at the highest frequencies quasi-optical and Fourier transform infrared spectroscopy (cf. Fig. 2). A detailed review of these techniques can be found in Kremer and Schonhals [37] and in Lunkenheimer [45], so that in the present context only a few aspects will be summarized. [Pg.137]

Different test methods are used to conduct permeability behaviors of plastics to measure gas, water, and other material vapor permeability. Permeability test procedures used to measure the permeability of plastic films include those identified as the absolute pressure method, the isostatic method, and the quasi-isostatic method. Basic approach mounts a plastic film sample between two cell chambers of a permeability cell (two piece closed container). One chamber holds the gas or vapor to be used as the permeant. The permeant then diffuses through the film into a second chamber, where a detection method such as optical devices, infrared spectroscopy, a manometric, gravimetric, or coulometric method isotopic counting or gas-liquid chromatography provides a quantitative measurement. [Pg.286]

In a variation of this method, Tencer and Stein (1978), mixed the isotopic quasi-racemate to near, but not exactly, zero rotation so that at a certain time, tz, the observed optical rotation of the reaction mixture was zero. The equations for this type of kinetic experiment enable one to calculate the difference between the individual isotopic rate constants from tz and the ratio of rate constants (the KIE) from te and tz provided that the ratio of the initial rotations for the two isotopic substrates is known. Usually it is preferable to... [Pg.236]

For excited state calculations, significant progress has been made based on the GW method first introduced by Hybertsen and Louie. [29] By considering quasi-partide and local field effects, this scheme has allowed accurate calculations of band gaps, which are usually underestimated when using the LDA. This GW approach has been applied to a variety of crystals, and it yields optical spectra in good agreement with experiment. [Pg.262]

Preferential crystallisation is one option for optical resolution on a manufacmr-ing scale. Online polarimetry and refractometry have been used to d3mamically optimise the process for resolution of DL-threonine in aqueous solution by variation of process parameters such as degree of supersaturation, seed quantity, initial enantiomeric excess and scale [148]. The method is claimed to be suitable for control of quasi-continuous processes. [Pg.262]

As discussed earlier, the concepts of chiral chromatography can be divided into two groups, the indirect and the direct mode. The indirect technique is based on the formation of covalently bonded diastereomers using an optically pure chiral derivatizing agent (CDA) and reacting it with the pair of enantiomers of the chiral analyte. The method of direct enantioseparation relies on the formation of reversible quasi diastereomeric transient molecule associates between the chiral selector, e.g., i /t)-SO, and the enantiomers of the chiral selectands, [R,S)-SAs [(Ry SA + (S)-SA] (Scheme 1). [Pg.193]

This method is based on the polarimetric measurement of the optical activity induced by the KIE in a reaction mixture containing an isotopic quasi-racemate, i.e. an approximately 50/50 mixture of the (+)-H and (-)-D substrate or vice versa, as one of the reactants. Variants of the method were independently reported by Bergson et al. (1977), Nadvi and Robinson (1978) and Tencer and Stein (1978). Later the method was successfully applied, particularly by Matsson and co-workers (Matsson, 1985 Hussgnius etal., 1989 Hussenius and Matsson, 1990) to determine both primary and secondary KIEs in proton transfer reactions, and by Sinnott and co-workers (Bennet et al., 1985 Ashwell et al., 1992 Zhang et al., 1994) to determine both primary and secondary as well as heavy-atom KIEs for reactions of carbohydrate derivatives. [Pg.234]

The synthesis of PP-fr-EPR can be accomplished by a stopped-flow polymerization method, whose polymerization time is very short and which is a quasi-living system, in the presence of a MgCl2-supported titanium catalyst [132-135]. The results of GPC, 13C NMR, CFC, DSC, and optical microscopic observation indicated the formation of a block copolymer having a chemical linkage between PP and EPR segments. [Pg.111]

It has been argued that, while the HOMO-LUMO energy difference suffers from systematic errors, a more reliable estimate of G can be obtained from the quasi-particle spectrum of the ionized system. For example, in NiO, the presence of an excess hole leads to the formation of a narrow band of unoccupied states in the VB region [249] (Fig. 11). It has been stressed [250] that the gap between this band and the CB edge approximates the optical/conductivity band gap. In Li NiO [251] and bulk NiO [249], this method yields a value of 4 eV, in agreement with optical absorption measurements [252]. It was also used to estimate G in an NiO(lOO) monolayer [85]. [Pg.67]


See other pages where Quasi-optical methods is mentioned: [Pg.16]    [Pg.140]    [Pg.16]    [Pg.140]    [Pg.87]    [Pg.96]    [Pg.94]    [Pg.347]    [Pg.101]    [Pg.216]    [Pg.1314]    [Pg.2238]    [Pg.393]    [Pg.119]    [Pg.274]    [Pg.310]    [Pg.239]    [Pg.153]    [Pg.367]    [Pg.366]    [Pg.147]    [Pg.150]    [Pg.345]    [Pg.363]    [Pg.27]    [Pg.310]    [Pg.285]    [Pg.31]    [Pg.74]    [Pg.336]    [Pg.35]    [Pg.137]    [Pg.141]    [Pg.310]    [Pg.45]   


SEARCH



Optical methods

© 2024 chempedia.info