Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Pump transient absorption scheme

A suitable method for a detailed investigation of stimulated emission and competing excited state absorption processes is the technique of transient absorption spectroscopy. Figure 10-2 shows a scheme of this technique. A strong femtosecond laser pulse (pump) is focused onto the sample. A second ultrashort laser pulse (probe) then interrogates the transmission changes due to the photoexcita-lions created by the pump pulse. The signal is recorded as a function of time delay between the two pulses. Therefore the dynamics of excited state absorption as... [Pg.169]

Transient terahertz spectroscopy Time-resolved terahertz (THz) spectroscopy (TRTS) has been used to measure the transient photoconductivity of injected electrons in dye-sensitised titanium oxide with subpicosecond time resolution (Beard et al, 2002 Turner et al, 2002). Terahertz probes cover the far-infrared (10-600 cm or 0.3-20 THz) region of the spectrum and measure frequency-dependent photoconductivity. The sample is excited by an ultrafast optical pulse to initiate electron injection and subsequently probed with a THz pulse. In many THz detection schemes, the time-dependent electric field 6 f) of the THz probe pulse is measured by free-space electro-optic sampling (Beard et al, 2002). Both the amplitude and the phase of the electric field can be determined, from which the complex conductivity of the injected electrons can be obtained. Fitting the complex conductivity allows the determination of carrier concentration and mobility. The time evolution of these quantities can be determined by varying the delay time between the optical pump and THz probe pulses. The advantage of this technique is that it provides detailed information on the dynamics of the injected electrons in the semiconductor and complements the time-resolved fluorescence and transient absorption techniques, which often focus on the dynamics of the adsorbates. A similar technique, time-resolved microwave conductivity, has been used to study injection kinetics in dye-sensitised nanocrystalline thin films (Fessenden and Kamat, 1995). However, its time resolution is limited to longer than 1 ns. [Pg.643]

An elegant way to study the dynamics from excited vibrational levels of the electronic ground state is to make use of the femtosecond pump dump probe scheme in transient absorption experiments. The molecular system is initially excited to the Si state and, using a second pulse of longer wavelength (the dump pulse), excited vibrational levels of the So state are populated via stimulated emission.197... [Pg.99]


See other pages where Pump transient absorption scheme is mentioned: [Pg.45]    [Pg.360]    [Pg.276]    [Pg.438]    [Pg.70]    [Pg.499]    [Pg.638]    [Pg.639]    [Pg.438]    [Pg.182]    [Pg.154]    [Pg.795]    [Pg.79]    [Pg.201]    [Pg.238]    [Pg.356]    [Pg.389]    [Pg.47]    [Pg.430]    [Pg.389]    [Pg.44]    [Pg.772]    [Pg.219]    [Pg.20]    [Pg.204]   
See also in sourсe #XX -- [ Pg.45 ]




SEARCH



Absorption pumps

© 2024 chempedia.info