Pulse Two-dimensional

One can now perform pulsed two-dimensional (2D) EPR spectroscopy completely in the time domain. - As a final example, Fig. 8 shows a 2D exchange spectrum of a spin-labeled peptide, using the pulse sequence tr/2-ti-tr/2-T-7r/2-t2, where T is the mixing time. During T the magnetization is stored parallel to Hq, and exchange between hyperfine lines can... [Pg.609]

Some discontinuities may be identified by a conventional two-dimensional ultrasonic technique, from which the well-known C-scan image is the most popular. The C-scan technique is relatively easy to implement and the results from several NDE studies have been very encouraging [1]. In the case of cylindrical specimens, a circular C-scan image is convenient to show discontinuity information. The circular C-scan image shows the peak amplitude of a back-scattered pulse received in the circular array. The axial scan direction is shown as a function of transducer position in the circular array. The circular C-scan image serves also as an initial step for choosing circular B-scan profiles. The latter provides a mapping between distance to the discontinuity and transducer position in the circular array. [Pg.201]

Time-resolved spectroscopy has become an important field from x-rays to the far-IR. Both IR and Raman spectroscopies have been adapted to time-resolved studies. There have been a large number of studies using time-resolved Raman [39], time-resolved resonance Raman [7] and higher order two-dimensional Raman spectroscopy (which can provide coupling infonuation analogous to two-dimensional NMR studies) [40]. Time-resolved IR has probed neutrals and ions in solution [41, 42], gas phase kmetics [42] and vibrational dynamics of molecules chemisorbed and physisorbed to surfaces [44]- Since vibrational frequencies are very sensitive to the chemical enviromnent, pump-probe studies with IR probe pulses allow stmctiiral changes to... [Pg.1172]

For quadnipolar nuclei, the dependence of the pulse response on Vq/v has led to the development of quadnipolar nutation, which is a two-dimensional (2D) NMR experiment. The principle of 2D experiments is that a series of FIDs are acquired as a fimction of a second time parameter (e.g. here the pulse lengdi applied). A double Fourier transfomiation can then be carried out to give a 2D data set (FI, F2). For quadnipolar nuclei while the pulse is on the experiment is effectively being carried out at low field with the spin states detemiined by the quadnipolar interaction. In the limits Vq v the pulse response lies at v and... [Pg.1478]

Muns ENDOR mvolves observation of the stimulated echo intensity as a fimction of the frequency of an RE Ti-pulse applied between tlie second and third MW pulse. In contrast to the Davies ENDOR experiment, the Mims-ENDOR sequence does not require selective MW pulses. For a detailed description of the polarization transfer in a Mims-type experiment the reader is referred to the literature [43]. Just as with three-pulse ESEEM, blind spots can occur in ENDOR spectra measured using Muns method. To avoid the possibility of missing lines it is therefore essential to repeat the experiment with different values of the pulse spacing Detection of the echo intensity as a fimction of the RE frequency and x yields a real two-dimensional experiment. An FT of the x-domain will yield cross-peaks in the 2D-FT-ENDOR spectrum which correlate different ENDOR transitions belonging to the same nucleus. One advantage of Mims ENDOR over Davies ENDOR is its larger echo intensity because more spins due to the nonselective excitation are involved in the fomiation of the echo. [Pg.1581]

These two reviews (Orrell et al and Perrin and Dwyer) cover the modem pulse and two-dimensional NMR teclmiques for studying exchange. [Pg.2114]

The pulse sequence which is used to record CH COSY Involves the H- C polarisation transfer which is the basis of the DEPT sequence and which Increases the sensitivity by a factor of up to four. Consequently, a CH COSY experiment does not require any more sample than a H broadband decoupled C NMR spectrum. The result is a two-dimensional CH correlation, in which the C shift is mapped on to the abscissa and the H shift is mapped on to the ordinate (or vice versa). The C and //shifts of the //and C nuclei which are bonded to one another are read as coordinates of the cross signal as shown in the CH COSY stacked plot (Fig. 2.14b) and the associated contour plots of the a-plnene (Fig. 2.14a and c). To evaluate them, one need only read off the coordinates of the correlation signals. In Fig. 2.14c, for example, the protons with shifts Sh= 1.16 (proton A) and 2.34 (proton B of an AB system) are bonded to the C atom at c = 31.5. Formula 1 shows all of the C//connectivities (C//bonds) of a-pinene which can be read from Fig. 2.14. [Pg.36]

The potential of LA-based techniques for depth profiling of coated and multilayer samples have been exemplified in recent publications. The depth profiling of the zinc-coated steels by LIBS has been demonstrated [4.242]. An XeCl excimer laser with 28 ns pulse duration and variable pulse energy was used for ablation. The emission of the laser plume was monitored by use of a Czerny-Turner grating spectrometer with a CCD two-dimensional detector. The dependence of the intensities of the Zn and Fe lines on the number of laser shots applied to the same spot was measured and the depth profile of Zn coating was constructed by using the estimated ablation rate per laser shot. To obtain the true Zn-Fe profile the measured intensities of both analytes were normalized to the sum of the line intensities. The LIBS profile thus obtained correlated very well with the GD-OES profile of the same sample. Both profiles are shown in Fig. 4.40. The ablation rate of approximately 8 nm shot ... [Pg.235]


See other pages where Pulse Two-dimensional is mentioned: [Pg.163]    [Pg.333]    [Pg.1011]    [Pg.333]    [Pg.355]    [Pg.333]    [Pg.263]    [Pg.388]    [Pg.1062]    [Pg.163]    [Pg.333]    [Pg.1011]    [Pg.333]    [Pg.355]    [Pg.333]    [Pg.263]    [Pg.388]    [Pg.1062]    [Pg.264]    [Pg.270]    [Pg.271]    [Pg.1434]    [Pg.1456]    [Pg.1497]    [Pg.1508]    [Pg.1528]    [Pg.1566]    [Pg.1575]    [Pg.1689]    [Pg.1983]    [Pg.1989]    [Pg.2108]    [Pg.2108]    [Pg.404]    [Pg.405]    [Pg.50]    [Pg.431]    [Pg.396]    [Pg.889]    [Pg.8]    [Pg.53]    [Pg.265]    [Pg.432]    [Pg.471]    [Pg.4]    [Pg.38]    [Pg.371]    [Pg.603]    [Pg.35]   
See also in sourсe #XX -- [ Pg.90 , Pg.93 , Pg.97 ]




SEARCH



One- and Two-dimensional Pulse Experiments

Two-dimensional pulse experiments

Two-dimensional pulsed electrophoresis