Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Process elemental analysis

Typically, PIXE measurements are perfonned in a vacuum of around 10 Pa, although they can be perfonned in air with some limitations. Ion currents needed are typically a few nanoamperes and current is nonnally not a limiting factor in applying the teclmique with a particle accelerator. This beam current also nonnally leads to no significant damage to samples in the process of analysis, offering a non-destmctive analytical method sensitive to trace element concentration levels. [Pg.1843]

Pittman, J. F.T. and Nakazawa, S., 1984. Finite element analysis of polymer processing operations. In Pittman, J.F. T., Zienkiewicz, O.C., Wood, R.D. and Alexander, J. M. (eds), Num,erical Analysis of Forming Processes, Wiley, Chichester. [Pg.16]

Pittman, J.F.T. and Nakazawa, S., 1984. Finite element analysis of polymer processing... [Pg.68]

Nassehi, V. and Ghoreishy, M, H. R., 1998. Finite element analysis of mixing in partially filled twin blade internal mixers. Int. Polym. Process. XIII, 231 -238. [Pg.189]

A development in the 1960s was that of on-line elemental analysis of slurries using x-ray fluorescence. These have become the industry standard. Both in-stream probes and centralized analyzers are available. The latter is used in large-scale operations. The success of the analyzer depends on how representative the sample is and how accurate the caUbration standards are. Neutron activation analyzers are also available (45,51). These are especially suitable for light element analysis. On-stream analyzers are used extensively in base metal flotation plants as well as in coal plants for ash analysis. Although elemental analysis provides important data, it does not provide information on mineral composition which is most cmcial for all separation processes. Devices that can give mineral composition are under development. [Pg.417]

Minimizing the cycle time in filament wound composites can be critical to the economic success of the process. The process parameters that influence the cycle time are winding speed, molding temperature and polymer formulation. To optimize the process, a finite element analysis (FEA) was used to characterize the effect of each process parameter on the cycle time. The FEA simultaneously solved equations of mass and energy which were coupled through the temperature and conversion dependent reaction rate. The rate expression accounting for polymer cure rate was derived from a mechanistic kinetic model. [Pg.256]

Diazoalkanes are u.seful is precursors to ruthenium and osmium alkylidene porphyrin complexes, and have also been investigated in iron porphyrin chemistry. In an attempt to prepare iron porphyrin carbene complexes containing an oxygen atom on the /(-carbon atom of the carbene, the reaction of the diazoketone PhC(0)C(Ni)CH3 with Fe(TpCIPP) was undertaken. A low spin, diamagnetic carbene complex formulated as Fe(TpCIPP)(=C(CH3)C(0)Ph) was identified by U V-visible and fI NMR spectroscopy and elemental analysis. Addition of CF3CO2H to this rapidly produced the protonated N-alkyl porphyrin, and Bit oxidation in the presence of sodium dithionitc gave the iron(II) N-alkyl porphyrin, both reactions evidence for Fe-to-N migration processes. ... [Pg.262]

The elemental analysis of a compound is usually determined by a laboratory that specializes in this technique. A chemist who has prepared a new compound sends a sample to the laboratory for analysis. The laboratory charges a fee that depends on the type and number of elements analyzed. The results are returned to the chemist as a listing of mass percent composition. The chemist must then figure out which chemical formula matches this composition. If a chemist has reason to expect a particular chemical formula, the observed percentages can be matched against the calculated percentages for the expected formula. This process is illustrated in Example 3-13. [Pg.156]

More interesting was the elemental analysis of the residue. Whereas a 2 1 AcOH [DMEpy]l should have contained 33% iodine, the elemental analysis indicated the residue contained only 0.7% iodine. This clearly indicated that we no longer had an iodide salt, but more likely had an acetate salt, most likely a 2 1 mixture of AcOH [DMEpy] [OAc]. (The formation of a 2 1 salt would be typical of our experience with ionic liquids. In practice they normally tenaciously retain ca. 2 mol AcOH/mol of ionic liquid, a phenomena we noted in om earlier reports. (3) Closer comparison of the salt obtained and low levels of Mel detected in the effluent indicated that the amount of [DMEpy] [OAc] generated closely matched the total Mel (ca. 90-95% yield of Mel based on [DMEpy][OAc].) Further, the elemental analysis was unable to detect any Rh in the effluent, so we could conclude that there was no aspiration occurring. This clearly indicated that our ionic liquid loss was due to metathesis of the ionic liquid from the iodide to the acetate salt, likely due to reaction (23) which likely sublimed overhead. In principle, the miniscule amount of Mel and ionic liquid could be returned to the reactor to maintain the process. [Pg.337]

Neutron activation analysis (NAA) is a supreme technique for elemental analysis (Section 8.6.1). Other nuclear analytical techniques, such as PIXE (Section 8.4.2) and RBS, also find application in investigations of diffusion processes [445]. [Pg.663]


See other pages where Process elemental analysis is mentioned: [Pg.256]    [Pg.256]    [Pg.1800]    [Pg.110]    [Pg.427]    [Pg.548]    [Pg.262]    [Pg.87]    [Pg.322]    [Pg.346]    [Pg.83]    [Pg.192]    [Pg.281]    [Pg.291]    [Pg.301]    [Pg.634]    [Pg.642]    [Pg.21]    [Pg.5]    [Pg.70]    [Pg.183]    [Pg.139]    [Pg.1]    [Pg.25]    [Pg.26]    [Pg.127]    [Pg.178]    [Pg.413]    [Pg.620]    [Pg.2]    [Pg.167]    [Pg.509]    [Pg.28]    [Pg.247]    [Pg.332]    [Pg.601]    [Pg.614]    [Pg.635]    [Pg.649]   
See also in sourсe #XX -- [ Pg.2 , Pg.336 ]




SEARCH



Elements Common To All Process Hazard Analyses

Process analysis

Process analysis processes

Processing analysis

Processing element

© 2024 chempedia.info