Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Practical Considerations During Installation

After another review of the practical constraints and technical considerations, it was concluded that an eductor vacuum-enhanced recovery system would be feasible and still be cost-effective and efficient. In all, 11 6-in.-diameter wells extending to a depth of 28 ft were installed at strategic locations in the area where product seeps were observed. Each well was serviced by a high-pressure supply and a low-pressure return line. A basic domestic-type deep-well eductor was installed in each well, attached to a drop pipe that extended to 25 ft below the surface. A check valve on the drop pipe prevented backflow into the well during service. The top of the casing... [Pg.367]


See other pages where Practical Considerations During Installation is mentioned: [Pg.23]    [Pg.167]    [Pg.140]    [Pg.23]    [Pg.122]    [Pg.687]    [Pg.1729]    [Pg.56]    [Pg.113]    [Pg.806]    [Pg.156]    [Pg.31]    [Pg.900]    [Pg.32]    [Pg.189]    [Pg.53]    [Pg.181]   