Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Variation position

We have presented a method to analyze the composite displacement and rotation movements. On Tables 1 and 2 we can see the agreement between the experimental values and that obtained from equations (1) or (2). This technique allows to follow the movement in real time, observing directly on the PC screen the ring size and position variations. In this way, we can determine the center and the radius of the ring. [Pg.659]

One of the primary benefits of pressure/denslty programming is peak compression that results in later eluting peaks having the same width, or an even narrower width, than the earliest peaks in the chromatogram. Qualitatively, this can be ascribed to either positional variations in mobile phase density or velocity along... [Pg.831]

When the defining set is small, there is an inadequate representation of the range of allowed positional variation in terms of either amino acid frequencies or types. Pseudo counts have been used for estimates of such unobserved data (Brown et al., 1993 Lawrence et al., 1993 Claverie, 1994 Tatusov et al., 1994 Henikoff and Henikoff, 1996 Sjo-lander et al., 1996). Such pseudo counts have been based on background frequencies, existing substitution matrices (Henikoff and Henikoff, 1992), and Dirichlet priors (Brown et al., 1993 Tatusov et al., 1994 Sjolander et al., 1996). Tatusov et al. (1994) reported that the Dirichlet priors (Brown et al., 1993 Sjolander et al., 1996) were most effective in... [Pg.166]

To calibrate the pixel sensitivities black body radiation is usually measured at different temperatures. Since a black body has an emissivity of 1 at every position, variations in detector pixel sensitivities are eliminated by a calibration function. As this IRT-method should be used here to quantify very small heat signals on combinatorial libraries with diverse materials, differences in emissivities have to be considered. Most materials are grey bodies with individual emissivities less than 1. Therefore, the calibration was not performed with a black body but with the library, as described before, a procedure that corrects not only for pixel sensitivity but also for emissivity differences across the library plate [5]. For additional temperature calibration, the IR-emission of the library is recorded at several temperatures in a narrow temperature window around the planned reaction temperature. By this procedure, emissivity changes, temperature dependence and individual sensitivities of the detector pixels can be calibrated in one step. After this... [Pg.177]

If the amount of mass transferred is analyzed, further conclusions on the carrier type (ionic/electronic) can be drawn according to Faraday s law, simply because of the fact that the pure stationary electronic flux will not cause mass displacements. If also the direction of mass transport is analyzed, e.g., by recording the position variation of the boundaries, cationic and anionic conductivities may be distinguished (Tubandt-Hittorf experiments). [Pg.77]

Protein Spot Positions. Protein spot positions can be measured to provide quantitative, statistical evidence of positional identity or difference for proteins in different gels. To accomplish this, the coordinates of the protein spot and of landmark (invariant) protein spots are recorded. Among six great apes 60% of the proteins were positionally invariant,6 and in a study of bears and procyonids 63% of proteins showed no positional variation.7 The mean protein spot position is determined from several gels, and outliers are defined statistically. [Pg.117]

Inversion barriers may then be qualitatively described as attractive dominant A or repulsive dominant R depending on which term Ex or Er shows the larger positive variation (AA and AR respectively) on going from the GS to the TS 155,167) and destabilizes the TS ). [Pg.86]

Substituent variation R, = Methyl or ethyl Homology variation R2 = Alkyl Position variation R3 = Amino Frequency variation m = 1-3... [Pg.51]

In practice, however, method A is better suited for determining quantitative kinetic data, while method B is more appropriate for studying subtle time-dependent fluorescence spectral shape and band position variations. [Pg.185]

In order to determine the kinetic parameters of the reaction corrected from diffusion phenomenon, a voltammetric investigation was pursued with a rotating platinum ring disk electrode. Figure 21.10 represents current density-potential curves obtained for different rotation speeds and for the positive variations of potential. It appears that the current density of the rotating disk increases with the rotation rate. [Pg.512]

Non-primary components such as cartons can also employ gauges, although obviously the type of gauge will be somewhat different, e.g. a transparent plastic line drawing of the carton profile, creases and scoring will show specification compliance if simply laid over the test carton. They can also show positional variation of identification and register code bars. [Pg.82]

Let us examine concentration fluctuations, Ac, in a volume V, small compared to the total volume occupied by a system. At equilibrium the free energy, has its minimum value, and its first derivative with respect to the concentration is zero. Consequently, the work required to cause fluctuations is determined by the second non-zero (positive) variation of the free energy, i.e. ... [Pg.342]

Kirby K.A. 1947. Methods for determination of positional variations in the subtalar and transverse tarsal joints. Anat. Rec. 80 397. [Pg.866]

A precipitation process can be operated under batch, semi-batch or continuous conditions, each of which will have its own distinct influence on the product crystal size distribution in addition to the combined influences of feedstock entry positions, variations in the reactant addition rate profile and mixing intensity (Tavare and Garside, 1990 Sohnel and Garside, 1992). [Pg.342]

Chemical Formula Index contains the formulas of the chemicals in this reference alphabetically ordered by their constituent elements. Note that in some cases there will be more than one chemical for each formula because many chemicals have the same formula with positional variations (e.g., o-, m-, p-). [Pg.6]

With thin specimens or specimens of limited quantity, much of the background is caused by the excitation radiation striking materials surrounding the specimen. It is important to keep all materials near the specimen to an absolute minimum, particularly the low-atomic-number materials that are efficient scatterers. It is much more difficult to control the vertical position of the specimen in the fluorescence spectrometer on materials supported by mylar films or filter paper. For this reason one can expect an error contribution in the range of 1 to 5% due to sample position variations. Frequently, the error due to counting statistics overshadows the sample position error on limited quantity specimens. [Pg.421]


See other pages where Variation position is mentioned: [Pg.364]    [Pg.175]    [Pg.185]    [Pg.167]    [Pg.172]    [Pg.181]    [Pg.166]    [Pg.316]    [Pg.5]    [Pg.36]    [Pg.146]    [Pg.299]    [Pg.50]    [Pg.696]    [Pg.3440]    [Pg.247]    [Pg.177]    [Pg.345]    [Pg.307]    [Pg.63]    [Pg.32]    [Pg.32]    [Pg.521]    [Pg.347]    [Pg.347]    [Pg.272]    [Pg.592]    [Pg.228]    [Pg.473]    [Pg.234]    [Pg.2406]   
See also in sourсe #XX -- [ Pg.200 ]




SEARCH



3-positivity conditions, variational

Ionic potential, positional variation

Molecular order variation with position

Pumps, positive-displacement flow variations

Variation of Residence Time with Channel Position

© 2024 chempedia.info