Platinum resistance

Co, by weight, is an extremely powerful magnet that offers a B-H (max) almost twice that of Alnico V. Platinum resistance wires are used for constructing high-temperature electric furnaces. [Pg.137]

The fixed points in the lTS-90 are given in Tabie 11.39. Platinum resistance thermometers are recommended for use between 14 K and 1235 K (the freezing point of silver), calibrated against the fixed points. Below 14 K either the vapor pressure of helium or a constant-volume gas thermometer is to be used. Above 1235 K radiometry is to be used in conjunction with the Planck radiation law,... [Pg.1215]

The ITS-90 has its lowest point at 0.65 K and extends upward without specified limit. A number of values assigned to fixed points differ from those of the immediately previous scale, IPTS-68. In addition, the standard platinum resistance thermometer (SPRC) is specified as the interpolation standard from 13.8033 K to 961.78°C, and the interpolation standard above 961.78°C is a radiation thermometer based on Planck s radiation law. Between 0.65 and 13.8033 K interpolation of the scale rehes upon vapor pressure and constant-volume gas thermometry. The standard thermocouple, which in previous scales had a range between the upper end of the SPRT range and the lower end of the radiation thermometer range, has been deleted. [Pg.399]

Whereas it is no longer an iaterpolation standard of the scale, the thermoelectric principle is one of the most common ways to transduce temperature, although it is challenged ia some disciplines by small iadustrial platinum resistance thermometers (PRTs) and thermistors. Thermocouple junctions can be made very small and ia almost infinite variety, and for base metal thermocouples the component materials are very cheap. Properties of various types of working thermocouple are shown in Table 3 additional properties are given in Reference 5. [Pg.402]

Temperature The level of the temperature measurement (4 K, 20 K, 77 K, or higher) is the first issue to be considered. The second issue is the range needed (e.g., a few degrees around 90 K or 1 to 400 K). If the temperature level is that of air separation or liquefact-ing of natural gas (LNG), then the favorite choice is the platinum resistance thermometer (PRT). Platinum, as with all pure metals, has an electrical resistance that goes to zero as the absolute temperature decreases to zero. Accordingly, the lower useful limit of platinum is about 20 K, or liquid hydrogen temperatures. Below 20 K, semiconductor thermometers (germanium-, carbon-, or silicon-based) are preferred. Semiconductors have just the opposite resistance-temperature dependence of metals—their resistance increases as the temperature is lowered, as fewer valence electrons can be promoted into the conduction band at lower temperatures. Thus, semiconductors are usually chosen for temperatures from about 1 to 20 K. [Pg.1136]

Industrial platinum resistance thermometer sensors Effects of unbalanced voltages on the performance of 30 cage induction motors BS EN 60751/1996... [Pg.319]

Fig. 21. Determination of the Mettler softening point. 1, heating element 2, platinum resistance thermometer 3, sample 4, light source 5, furnace 6, sample cup 7, photo cell 8, collector sleeve (see p. 48 in [25]). Fig. 21. Determination of the Mettler softening point. 1, heating element 2, platinum resistance thermometer 3, sample 4, light source 5, furnace 6, sample cup 7, photo cell 8, collector sleeve (see p. 48 in [25]).
Between the fixed points, temperatures on the ITS-90 are obtained by interpolation using standard instruments and assigned formulae. These standard instruments are the helium gas thermometer (3 K to 24.5 K), the platinum resistance thermometer (13.8 K to 1235 K), and the optical thermometer (above 1235 K). [Pg.1140]

The so-called standard instrument is used for interpolation between the fixed points and for the calibration of other thermometers lower in the metrological hierarchy. The standard instrument in the moderate temperature range is a special platinum resistance probe, as it has to fulfill set requirements. It is important in all calibration that traceability to a primary normal, here the fixed-point ITS-90 scale, exists. [Pg.1140]

H. Breunig, F. Lieneweg. Handbucb der technischen Temperaturmessung. Vieweg, 1976. lEC 60751 (1983-01). Industrial Platinum Resistance Thermometer Sensors. International Electrotechnical Commission, 1983. [Pg.1174]

ASTM El 137-97. Standard Specification for Industrial Platinum Resistance Thermometers. American Society for Testing and Materials, 1997. [Pg.1174]

Oxaliplatin belongs to the group of diaminocyclohex-ane platinum complexes that can overcome platinum resistance. Its place in the primary and adjuvant treatment of colon cancets is being defined. It is prominently neurotoxic. [Pg.57]

Electrical resistance thermometers, the most widely used of which is Callendar s platinum resistance thermometer. This is probably the most convenient and accurate apparatus for measuring temperatures between the boiling-point of liquid air (—190° C.) and the melting-point of platinum (1,500° C.). Lead has recently been applied at very low temperatures. [Pg.3]

With the same apparatus as in example (1), the absolute temperature of the gas in its initial state was Ti. The tap was then opened so that the gas rapidly expanded to atmospheric pressure, and the temperature, determined immediately after expansion by a platinum resistance thermometer, or a thermo-element, in the centre of the vessel, was T2. Show that ... [Pg.145]

These fixed points are used to calibrate a different kind of thermometer that is easier to use than a gas thermometer. Over the temperature range from 13.8033 to 1234.93 °A (or K), which is the temperature interval most commonly encountered, the thermometer used for ITS-90 is a platinum resistance thermometer. In this thermometer, the resistance of a specially wound coil of platinum wire is measured and related to temperature. More specifically, temperatures are expressed in terms of W(T9o), the ratio of the resistance R(Ttriple point of water R (273.16 K), as given in equation (1.11)... [Pg.13]

The international temperature scale is based upon the assignment of temperatures to a relatively small number of fixed points , conditions where three phases, or two phases at a specified pressure, are in equilibrium, and thus are required by the Gibbs phase rule to be at constant temperature. Different types of thermometers (for example, He vapor pressure thermometers, platinum resistance thermometers, platinum/rhodium thermocouples, blackbody radiators) and interpolation equations have been developed to reproduce temperatures between the fixed points and to generate temperature scales that are continuous through the intersections at the fixed points. [Pg.617]

The ITS-90 scale is designed to give temperatures T90 that do not differ from the Kelvin Thermodynamic Scale by more than the uncertainties associated with the measurement of the fixed points on the date of adoption of ITS-90 (January 1, 1990), to extend the low-temperature range previously covered by EPT-76, and to replace the high-temperature thermocouple measurements of IPTS-68 with platinum resistance thermometry. The result is a scale that has better agreement with thermodynamic temperatures, and much better continuity, reproducibility, and accuracy than all previous international scales. [Pg.618]

The deviation function AW Too) is obtained as a function of r90 for various temperature intervals by calibration of the platinum resistance thermometer, using specified fixed points from Table A2.1. The form of the AW(Too) function is dependent on the temperature range in which the thermometer is being calibrated. For example, in the temperature subrange from 234.3156 to 302.9146 K, the form of the deviation function is... [Pg.622]

In summary, to obtain 7% from a platinum resistance thermometer, one selects the range of interest, calibrates the thermometer at the fixed points specified for those ranges, and uses the appropriate function to calculate AW(Tw) to be used in equation (A2.5). Companies are available that perform these calibrations and provide tables of W T<)0) versus 790 that can be interpolated to give 7% for a measured W T90). [Pg.624]

Compare and contrast chemotherapy options for women with recurrent platinum-resistant... [Pg.1385]

Single-agent chemotherapy is standard practice for recurrent platinum-resistant ovarian cancer. [Pg.1385]

Since the efficacy of the agents is similar, selection of an agent for the treatment of recurrent platinum-resistant ovarian cancer depends on residual toxicities, physician preference, and patient convenience. [Pg.1385]

TABLE 91-3. Summary of Chemotherapy Agents Used for Second-Line Treatment of Progressive and Recurrent Platinum-Resistant Ovarian Cancer... [Pg.1393]

As understanding of the mechanisms of platinum resistance has increased, more rationally designed platinum derivatives have been synthesized. One approach has been to insert steric... [Pg.817]


See other pages where Platinum resistance is mentioned: [Pg.1905]    [Pg.1908]    [Pg.925]    [Pg.180]    [Pg.384]    [Pg.20]    [Pg.397]    [Pg.399]    [Pg.399]    [Pg.406]    [Pg.445]    [Pg.77]    [Pg.168]    [Pg.242]    [Pg.301]    [Pg.521]    [Pg.73]    [Pg.353]    [Pg.621]    [Pg.1389]    [Pg.1391]    [Pg.1392]    [Pg.1392]    [Pg.1392]   


SEARCH



Industrial platinum resistance thermometer

Metallic resistance thermometer platinum

Ovarian cancer platinum-resistant

Platinum antitumor compounds resistance

Platinum corrosion resistant alloys

Platinum electrical resistivity

Platinum resistance mechanisms

Platinum resistance of wires

Platinum resistance temperature detector

Platinum resistance thermometers PRTs)

Platinum resistant cell line

Platinum resistivity

Platinum resistivity

Precision platinum resistance thermometer

Standard platinum resistance

Standard platinum resistance thermometers

Temperature measurement platinum resistance thermomete

Temperature platinum resistance

Thermometer platinum resistance