Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Phase resolution

Figure 10.12 shows the phase difference measured between channels of each pair when no phase change was introduced in any of the channels. The phase resolution (S/N =1) for each pair of channels, as determined from these measurements, is 1 xlO 4 x 2n, which corresponds to a refractive index resolution of —8.5 x 10 8 RIU (refractive index units) at a bandwidth of 1 Hz. [Pg.281]

Figure 5.6—Example of interdependency of R/ values on resolution in an HPLC column. It is possible to transpose results obtained by TLC onto HPLC using the same phases. Resolution between two compounds on a TLC plate varies with the distance of migration on the plate. Resolution passes through a maximum for an Rf value in the order of 0.3. Figure 5.6—Example of interdependency of R/ values on resolution in an HPLC column. It is possible to transpose results obtained by TLC onto HPLC using the same phases. Resolution between two compounds on a TLC plate varies with the distance of migration on the plate. Resolution passes through a maximum for an Rf value in the order of 0.3.
Analytical Properties Ionically bonded to silica, this phase provides good resolution of enantiomeric quasiequatorial frans-dehydriols of unsubstituted and methyl- and bromo-substituted benz[a]anthracene derivatives covalently bonded to silica, this phase provides good resolution of enantiomeric pairs of quasidiaxial frans-dihydrodiols of unsubstituted and methyl- and bromo-substituted benz[a]anthracene derivatives by addition of a third solvent (chloroform) to the classical binary mixture (hexane-alcohol) of the mobile phase, resolution of enantiomers of tertiary phosphine oxides is possible Reference 31-33, 36, 37... [Pg.158]

Ellipsometry Spectroscopic ellipsometry Imaging ellipsometry Adsorbed amounts/coverages phase transitions thickness and refractive indices. Identification of interfacial molecules. Domain formation eind shape (coexisting phases) internal structure of condensed phases resolution O (1 gm). For interpretation in terms of molecular structure model profiles across the Interface are needed. Problems mono-layer anisotropy, and different profiles may match the experimental data additional (independent) information required. [Pg.338]

An attractive aspect of this device is the possibility of using long interaction lengths, in this way increasing the sensitivity of the device. An MZI offering a phase resolution of 0.002ir, which corresponds to a refractive-index resolution of 10 has been described [51]. A theoretical study shows that the Mach-Zehnder interferometer sensor seems to be one of the more promising concepts [15] for detection of low concentrations of small molectdes without labels (10 M or even lower). [Pg.432]

Body Area Excitement Phase Orgasm Phase Resolution Phase... [Pg.659]

Scheme 5. The Width and Wealth of Applications of the TADDOL System. Some of the topics listed will be the subject of the following Schemes (cholesteric phases resolutions solid-state reactions conversions involving Mg, Al, Cu, Zn, Ti, Mo, Rh, Pd polymer-bound TADDOLs), therefore references are given herein only for those appMcations which will not he... Scheme 5. The Width and Wealth of Applications of the TADDOL System. Some of the topics listed will be the subject of the following Schemes (cholesteric phases resolutions solid-state reactions conversions involving Mg, Al, Cu, Zn, Ti, Mo, Rh, Pd polymer-bound TADDOLs), therefore references are given herein only for those appMcations which will not he...
On the Store page (Fig. 10.41) specify the wavenumber range and the spectrum type to be saved. Notice that the calculated spectrum block always is of type Single-Channel In addition, one can also save the Phase spectrum and the Power spectrum, which can be calculated from the parts of the interferogram known from forward and backward scans with the Phase Resolution setting. [Pg.105]

The Phase Resolution is the resolution for computing the phase. Normally the same resolution as was used for the measurement should be used. [Pg.107]

Figure 10.46. The Raman spectrum of sulphur in the spectral range 100-280 cm calculated by Fourier transformation of the interferogram top, no apodization (boxcar) bottom, apodization function Norton-Beer weak. In both cases, a zerofilling factor of 2 and the power spectrum for phase correction were chosen. Further parameter used Store page selected frequencies for file first 9394 and last 5894 Limit data page limit resolution to 4 cm, limit phase resolution to 32 cm, direction both, data points both Peak search page mode absolute largest value, symmetry of the interferogram automatic. Figure 10.46. The Raman spectrum of sulphur in the spectral range 100-280 cm calculated by Fourier transformation of the interferogram top, no apodization (boxcar) bottom, apodization function Norton-Beer weak. In both cases, a zerofilling factor of 2 and the power spectrum for phase correction were chosen. Further parameter used Store page selected frequencies for file first 9394 and last 5894 Limit data page limit resolution to 4 cm, limit phase resolution to 32 cm, direction both, data points both Peak search page mode absolute largest value, symmetry of the interferogram automatic.
Phase-Resolution. Phase-resolved fluorescence spectroscopy (PRFS)... [Pg.383]

Bioimpedance measurements were conducted with a BIS device (SFB7, ImpediMed, Pinkeba, Australia) covering a frequency range of 5 kHz to 1 MHz. This device has an impedance accuracy of 1% and a phase resolution of 0.1° using adhesive electrodes. To ensure rehable measurements, the body position was not altered and electrode sites were cleaned before attaching the electrodes. For this trial, the whole-body and hand-to-hand bioimpedance is analyzed. Extracellular resistance intracellular resistance (i ,) and capacitive effects CJ are calculated using the Cole model [6]. [Pg.31]

For evaluation of the pelvic sidewall and lymph node staging, an additional proton-density or a Tl-weighted sequence in transverse orientation should be performed (see Fig. 7.11). The acquisition starts at the level of the aortic bifurcation and extends to below the pelvic floor. A slice thickness of 6 mm is used, with a 512 matrix and a phase resolution of at least 60%. Complete coverage of the inguinal lymph nodes should be attempted in patients with cervical cancers involving the lower third of the vagina (stage IIIA... [Pg.133]

Due to the phase resolution of the electrochemical response of the electrode the non-faradaic effects (the equivalence of the charging ... [Pg.6]


See other pages where Phase resolution is mentioned: [Pg.516]    [Pg.366]    [Pg.29]    [Pg.61]    [Pg.263]    [Pg.264]    [Pg.523]    [Pg.727]    [Pg.119]    [Pg.154]    [Pg.147]    [Pg.339]    [Pg.535]    [Pg.43]    [Pg.3]    [Pg.242]    [Pg.263]    [Pg.264]    [Pg.106]    [Pg.389]    [Pg.389]    [Pg.623]    [Pg.81]    [Pg.132]    [Pg.253]    [Pg.357]    [Pg.174]    [Pg.465]    [Pg.644]    [Pg.412]    [Pg.324]    [Pg.446]   
See also in sourсe #XX -- [ Pg.383 ]




SEARCH



© 2024 chempedia.info