Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Peripheral numbering

In peripheral numbering of the complete fused systems, the ring system is oriented and numbered according to the principles of Rule A-22. When there is a choice of orientations, it is made in the following sequence in order to ... [Pg.300]

The numbering of the skeleton in a ring system is generally a consequence of the way in which the skeleton is named. In order to avoid confusion as to the peripheral numbering sequence and locations of substituents in the fused systems, structural formulae are drawn as in Chemical Abstracts in accordance with the rules of heterocyclic nomenclature. Thereby the reader is not required to possess detailed knowledge of the elaborate series of priorities used in the structural presentation and numbering of ring systems. [Pg.616]

The next family of materials, which are to be discussed all possess cyanobiphenyl moieties as the mesogenic units. The systematic studies of the liquid crystal properties are described in terms of spacer length and peripheral number density. The first material, 37, shown in Fig. 35, is an octamer based on the octasilsesquioxane core unit [86]. This material was prepared and purified in such a way that by HPLC and 29Si NMR spectroscopy it was shown to be a single compound without dispersity. The material was found to exhibit smectic polymorphism with SmC and SmA phases being formed. The incorporation of cyanobiphenyl mesogenic moieties means that the material has interesting... [Pg.31]

The confusion that can arise when the formula of a relatively simple fused heterocycle is wrongly drawn may be illustrated with a tricyclic compound which may be drawn in several ways, some of which are shown in (1,8) to (1.12). None of these is in accord with lUPAC recommendations (1.13) is the correct formula and is the one that should be used. Peripheral numbering of this compound is shown and its name is pyrazinol2, 3 4.5]thieno[3,2-[Pg.21]

If additional benzo units are likewise ortho-insed to the above pentacyclic system, helical structures result which can be specified as hexa-,hepta- etc. -helicenes. Since the current rules lead to confusing variable peripheral numberings for individual members of that compound class, a new consistent numbering scheme has been proposed according to which numbering always starts at one end of the helix and proceeds sequentially to the other. [Pg.24]

Conclusive peripheral numbering of fused heterocyclic systems must first of all pay attention to the generalized orientation rules detailed for corresponding carbocyclics (p. 22). If these are not sufficient, that orientation is chosen which leads to lowest locants by evaluating the following criteria one after another ... [Pg.61]

Isomers are distinguished by lettering the peripheral sides of the parent beginning with a for the side 1,2, and so on, lettering every side around the periphery. If necessary for clarity, the numbers of the attached position (1,2, for example) of the substituent ring are also denoted. The prefixes are cited in alphabetical order. The numbers and letters are enclosed in square brackets and placed immediately after the designation of the attached component. Examples are... [Pg.9]

Grinder Variables. The quaUty of pulp depends on wood species, moisture content, and grinder variables such as peripheral stone speed, grit size and number per unit area, and pattern on the stone surface. Process variables that affect pulp quaUty include grinding pressure pit consistency, ie, consistency in the space immediately below the grinder (2—6%) and temperature (40—80°C). The combination of moisture and raised temperature tends to soften the lignin. [Pg.259]

A large number of thyroid hormone analogues have been tested for this effect (6). Among others, i-T (3) and 3,3 -T2 (5) and their propionic acid side-chain analogues decrease oxygen consumption at molar ratios of 50—200 1 of T. Nevertheless, no potent or clinically usehil peripheral antagonists have been found. [Pg.53]

For designating the position of fusion, the peripheral bonds of the base component, starting with the 1,2-bond, are consecutively assigned italic letters in alphabetical order, following the direction of numbering thus in quinoxaline (35) the 1,2-bond is assigned... [Pg.21]

The structure of heart myocytes is different from that of skeletal muscle fibers. Heart myocytes are approximately 50 to 100 p,m long and 10 to 20 p,m in diameter. The t-tubules found in heart tissue have a fivefold larger diameter than those of skeletal muscle. The number of t-tubules found in cardiac muscle differs from species to species. Terminal cisternae of mammalian cardiac muscle can associate with other cellular elements to form dyads as well as triads. The association of terminal cisternae with the sarcolemma membrane in a dyad structure is called a peripheral coupling. The terminal cisternae may also form dyad structures with t-tubules that are called internal couplings (Figure 17.31). As with skeletal muscle, foot structures form the connection between the terminal cisternae and t-tubule membranes. [Pg.559]

An average value is about 0.55 for the coefficient, p. Peripheral velocities will usually vary between 600-900 ft/sec however, this varies with the gas being compressed and may run up to 1,100 ft/sec. The results of this head calculation will give values of 8,000-12,000 ft for a single stage. From this value, the total number of stages in the compressor can be approximated. [Pg.489]

Mach Number Usual practice uses the peripheral velocity, u, of the... [Pg.498]

Systems may also include modems, which connect small computers or terminals to other computers or workstations either in-house or over telephone system lines and whose speed of transmission is rated by baud (for binary information units, the number of bits transmitted per second). Common baud rates for small systems are 2400 or 9600 with higher rates possible. Computers may also be networked together to share data or peripheral components such as highspeed printers. [Pg.132]

Term (4) is effectively a Reynolds number with the velocity the peripheral speed and the characteristic dimension being usually the maximum impeller diameter. [Pg.490]

Porphyrins are formally derived from the porphin (1) nucleus by substitution of some or all peripheral positions with various side chains. In the classical system of nomenclature T, introduced by H. Fischer,Sc the peripheral /5-pyrrolic positions are numbered front 1 to 8 and the methine positions (also named meso positions) between the pyrrole rings are designated a, //, y, and 5. The rings are lettered clockwise A, B, C, and D. The classical nomenclature was in the past more and more displaced by a nomenclature which numbers all the carbon... [Pg.578]


See other pages where Peripheral numbering is mentioned: [Pg.1342]    [Pg.1342]    [Pg.16]    [Pg.17]    [Pg.20]    [Pg.9]    [Pg.834]    [Pg.646]    [Pg.1342]    [Pg.1342]    [Pg.16]    [Pg.17]    [Pg.20]    [Pg.9]    [Pg.834]    [Pg.646]    [Pg.521]    [Pg.408]    [Pg.496]    [Pg.496]    [Pg.23]    [Pg.229]    [Pg.217]    [Pg.126]    [Pg.132]    [Pg.217]    [Pg.92]    [Pg.1204]    [Pg.1898]    [Pg.279]    [Pg.528]    [Pg.59]    [Pg.55]    [Pg.111]    [Pg.444]    [Pg.378]    [Pg.48]    [Pg.724]    [Pg.56]    [Pg.84]    [Pg.158]   
See also in sourсe #XX -- [ Pg.24 , Pg.61 ]




SEARCH



© 2024 chempedia.info