Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Patch labelling

Another opportunity for change might be decorative. If labels are used and need to be retained then the method of printing should be discussed with the label manufacturer and examined in terms of print effect versus cost. The label substrate can help to create an impression of quality through the use of plastic, either in conjunction with paper in laminate form or in monolayer form. Whether the labels are pre-cut or reel-fed will also impact on whether the label can be a shaped patch label or is wrapped around the package. [Pg.202]

Hair colorants, the fourth class of color additives, may be used only to color scalp hair and may not be used in the area of the eye. Use of these colorants is exempt, that is, coal-tar hair dyes may be sold with cautionary labeling, directions for preliminary (patch) testing, and restrictions against use in or near the eye. The EDA diligently enforces the rules governing color additives and limits the use of, or even dehsts colorants deemed unsafe. The Hst of substances specifically prohibited for use in cosmetics is short. [Pg.286]

Patches are removed from the test subject immediately after the study replicate is completed. The Field Scientist should wear disposable surgical gloves to remove the patches and change gloves often to reduce the chance of cross-contamination of samples. Individual patches are wrapped in aluminum foil prior to placing them in a pre-labeled sealable plastic bag. Combined patches are placed exposed face to face, wrapped in aluminum foil, and stored frozen in sealable plastic bags. Patch samples may be placed in dry-ice in a cooler or directly into a freezer for storage. [Pg.1004]

Reaction with Cr(III) Modified Plastocyanin. From thermo-lysin proteolysis experiments Farver and Pecht (20) have concluded that reduction of PCu(II) with labelled Cr0 20)52+ (1 1 mole amounts) at pH 7 gives a product in which Cr(III) is attached to the peptide chain 40-49. Coordination of the Cr at one or two carboxylates in the 42-45 patch is favoured. It has now been demonstrated that rate constants (25oC) for the reaction of PCu(I).Cr(III) + Co(phen)33+ are decreased by 16%. [Pg.185]

Figure 6.8 Labelled RedEye oxygen patch (Ocean Optics). Figure 6.8 Labelled RedEye oxygen patch (Ocean Optics).
Simpson DM, Estanislao L, Brown SJ, Sampson J. (2008) An open-label pilot study of high-concentration capsaicin patch in painful hiv neuropathy. J Pain Symptom Manage 35 299-306. [Pg.152]

Harmon Clonidine Open-label n = 7 Moderate—great improvement in ag- Sedation, patch... [Pg.584]

Fig. 4. Schematic representation of transient method employed by Devaux and McConnell9 to measure the rates of lateral diffusion of phospholipids in model membranes. The upper diagram represents a concentrated patch of labels at the beginning of the experiment, time f = 0. At later times f>0, the molecules diffuse laterally, as shown in the lower two drawings. The paramagnetic resonance spectra depend on the spin-label concentration in the plane of the membrane, and an analysis of the time dependence of these spectra yielded the diffusion constant. [Reprinted with permission from P. Devaux and H. M. McConnell, J. Am. Chem. Soc., 94, 4475 (1972). Copyright by American Chemical Society.]... Fig. 4. Schematic representation of transient method employed by Devaux and McConnell9 to measure the rates of lateral diffusion of phospholipids in model membranes. The upper diagram represents a concentrated patch of labels at the beginning of the experiment, time f = 0. At later times f>0, the molecules diffuse laterally, as shown in the lower two drawings. The paramagnetic resonance spectra depend on the spin-label concentration in the plane of the membrane, and an analysis of the time dependence of these spectra yielded the diffusion constant. [Reprinted with permission from P. Devaux and H. M. McConnell, J. Am. Chem. Soc., 94, 4475 (1972). Copyright by American Chemical Society.]...
One more characteristic of these patches is that they are arranged in a random way on the surface of the electrode. We can number the patches according to their value of Qt, and label them with a parameter 5 that will vary from 0 to 1, i.e., 0 < s < 1. Thus, the heat of adsorption for each patch can be written as... [Pg.223]

Devers, A. and Galer, B. S.. Topical lidocaine patch relieves a variety of neuropathic pain conditions An open-label study, Clin. J. Pain 2000, 16, 205-208. [Pg.326]

Labels must be applied to a flat or two-dimensional surface. Compound curves result in the label creasing and looking unsightly. A label can be a patch, which may be square or rectangular or shaped into a particular profile. Shaped labels are usually used for products with a premium positioning. [Pg.231]

Gammaitoni AR, Galer BS, Onawola R, et al. Lidocaine patch 5% and its positive impact on pain qualities in osteoarthritis results of a pilot 2-week, open-label study using the Neuropathic Pain Scale. Curr Med Res Opin. 2004 20(suppl 2) S13—S19. [Pg.158]


See other pages where Patch labelling is mentioned: [Pg.39]    [Pg.213]    [Pg.450]    [Pg.466]    [Pg.51]    [Pg.235]    [Pg.39]    [Pg.213]    [Pg.450]    [Pg.466]    [Pg.51]    [Pg.235]    [Pg.458]    [Pg.486]    [Pg.76]    [Pg.84]    [Pg.183]    [Pg.212]    [Pg.1006]    [Pg.582]    [Pg.157]    [Pg.206]    [Pg.12]    [Pg.28]    [Pg.326]    [Pg.358]    [Pg.156]    [Pg.157]    [Pg.162]    [Pg.252]    [Pg.259]    [Pg.380]    [Pg.243]    [Pg.285]    [Pg.488]    [Pg.296]    [Pg.26]    [Pg.268]    [Pg.585]    [Pg.257]    [Pg.458]    [Pg.1675]    [Pg.91]   
See also in sourсe #XX -- [ Pg.51 ]




SEARCH



Patches

© 2024 chempedia.info