Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Passive sampling calibration methods

Ouyang, G. and J. Pawhszyn. 2007. Configurations and calibration methods for passive sampling techniques.. /. Chromatogr. A 1168 226-235. [Pg.62]

In order to assess the accuracy of the present method, we compared it with two other methods. One was the Track Etch detector manufactured by the Terradex Corp. (type SF). Simultaneous measurements with our detectors and the Terradex detectors in 207 locations were made over 10 months. The correlation coefficient between radon concentrations derived from these methods was 0.875, but the mean value by the Terradex method was about twice that by our detectors. The other method used was the passive integrated detector using activated charcoal which is in a canister (Iwata, 1986). After 24 hour exposure, the amount of radon absorbed in the charcoal was measured with Nal (Tl) scintillation counter. The method was calibrated with the grab sampling method using activated charcoal in the coolant and cross-calibrated with other methods. Measurements for comparison with the bare track detector were made in 57 indoor locations. The correlation coefficient between the results by the two methods was 0.323. In the case of comparisons in five locations where frequent measurements with the charcoal method were made or where the radon concentration was approximately constant, the correlation coefficient was 0.996 and mean value by the charcoal method was higher by only 12% than that by the present method. [Pg.187]

Determination of uranium in soil samples can be carried out by nondestructive analysis (NDA) methods that do not require separation of uranium (needed for alpha spectrometry or TIMS) or even digestion of the soil for analysis by ICPMS, ICPAES, or some other spectroscopic methods. These NDA methods can be divided into passive techniques that utilize the natural radioactive mission (gamma and x-ray) of the uranium and progeny radionuclides or active methods where neutrons or electromagnetic radiation are used to excite the uranium and the resultant emissions (gamma, x-rays, or neutrons) are monitored. In many cases, sample preparation is simpler for these nondestructive methods but the requiranent of a neutron source (from a nuclear reactor in many cases) or a radioactive source (x-ray or gamma) and relatively complex calibration and data interpretation procedures make the use of these techniques competitive only in some applications. In addition, the detection limits are usually inferior to the mass spectrometric techniques and the isotopic composition is not readily obtainable. [Pg.135]


See other pages where Passive sampling calibration methods is mentioned: [Pg.7]    [Pg.74]    [Pg.66]    [Pg.297]    [Pg.299]    [Pg.474]    [Pg.138]    [Pg.141]    [Pg.86]    [Pg.64]    [Pg.441]    [Pg.250]    [Pg.50]    [Pg.56]    [Pg.58]    [Pg.62]    [Pg.249]    [Pg.181]    [Pg.257]    [Pg.865]   
See also in sourсe #XX -- [ Pg.58 , Pg.59 , Pg.62 ]




SEARCH



Calibration samples

Method calibration

Passive sampling

Sample methods

Sampling methods

© 2024 chempedia.info