Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Oxygen concentrator device

Alternatives to Arresters Alternatives to the use of flame arresters include fast-ac ting isolation valves, vapor suppression systems, velocity-type devices in which gas velocity is designed to exceed flashback velocity, and control of the flammable mixture (NFPA 69 standard, Explosion Prevention Systems ). The latter alternative frequently involves reduction of oxygen concentration to less than the limiting oxygen concentration (LOC) of the gas stream. [Pg.2305]

Incorporated in a device, the LPCVD -Si H material shows electroluminescence only in reverse bias [673]. The mechanism is similar to the one described for c-Si. The PECVD a-Si H material was incorporated in a p-i-n solar cell structure, with a thickness of the intrinsic layer of 500 nm (see Section 1.11.1). Oxygen was coimplanted at 80 keV (3.2 x 10 O/em-) and at 120 keV (5.5 x lO 0/cm ), which resulted in a roughly constant oxygen concentration of 1.0% in the Er projected range in the middle of the intrinsic a-Si H layer. Electroluminescence is observed under forward bias [674]. [Pg.188]

Second in popularity only to the pH electrode is the oxygen electrode. This device is a polarographic electrode system that can be used to measure oxygen concentration in a liquid sample or to monitor oxygen uptake or evolution by a chemical or biological system. [Pg.44]

Ion sputtering mass spectrometry has been applied to several problems in the analysis of solids with various types of instruments. These include studies of semiconductor devices as shown in Fig. 3. oxygen concentrations and concentration gradients and of processes of oxidation in a variety of metals, some catalytic and corrosion processes on metals, and the chemistry of trace elements in geologic specimens. The distribution of trace elements in lunar rocks has also been studied. [Pg.867]

Brunei M, Ozkul C, Sanchez F. Nonlinear optical devices for oxygen concentration measurements. Sens Actuators 2000 B62 238 13. [Pg.289]

Oxygen sensors — Device for measurement of oxygen concentration or activity. See - Clark cell, - lambda-probe. [Pg.480]

Maximum biofilter inlet pollutant concentration For an aerobic fixed-film device, the local total flux for all pollutants into the biofilm must not exceed the local flux of oxygen into the biofilm, on a stoichiometric basis. Therefore, the maximum acceptable total pollutant concentration is fixed, at the biofilter inlet, by the low maximum oxygen solubility in the biofilm, at the biofilm interface. This oxygen concentration is about 8 mg/L (8 ppm) for air at ambient conditions. If the total pollutant concentration exceeds this maximum limit, aerobic biological conditions cannot be maintained throughout the biofilter, a condition which can result in biofilter failure. [Pg.48]

The SOFC has been wrongly described in the early literature as an oxygen concentration cell. On the contrary, the author asserts that all fuel cells are ion concentration devices. Also that zero external current cell equilibrium equates to an internal balanced state, at which no net ion transfer occurs between electrodes, due to a balance between counter-directed ion migration and diffusion. The SOFC (Mobius and... [Pg.70]


See other pages where Oxygen concentrator device is mentioned: [Pg.545]    [Pg.57]    [Pg.545]    [Pg.57]    [Pg.483]    [Pg.506]    [Pg.124]    [Pg.282]    [Pg.504]    [Pg.84]    [Pg.97]    [Pg.151]    [Pg.32]    [Pg.42]    [Pg.98]    [Pg.483]    [Pg.506]    [Pg.38]    [Pg.136]    [Pg.141]    [Pg.144]    [Pg.148]    [Pg.150]    [Pg.150]    [Pg.186]    [Pg.200]    [Pg.120]    [Pg.195]    [Pg.276]    [Pg.372]    [Pg.193]    [Pg.284]    [Pg.71]    [Pg.1051]    [Pg.231]    [Pg.344]    [Pg.345]    [Pg.385]    [Pg.2670]    [Pg.2599]    [Pg.29]   
See also in sourсe #XX -- [ Pg.545 ]




SEARCH



Oxygen concentration

Oxygen concentrators

© 2024 chempedia.info