Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Unimportant outputs

Both the capillary LC and NMR are controlled by the interface software, which enables the operator to use the UV-detector output for peak selection. Only peaks of interest can be subjected to NMR analysis, while minor or unimportant compounds can be directed to waste. NMR acquisition can take place in either on-flow or stop-flow mode. The combination of capillary LC and NMR is suitable for sample-limited applications (e.g., proteomics) and allows for low nanograms detection. [Pg.577]

In defining precisely the criterion of reactor output, it is convenient to use one particular reactant as a reference rather than the product formed. The distinction is unimportant if there is only one reaction, but is necessary if more than one reaction is involved. The unit output WA of a reactor system may thus be defined as the moles of reactant A converted, per unit time, per unit volume of reaction space in calculating this quantity it should be understood that the total moles converted by the whole reactor in unit time is to be divided by the total volume of the system. The unit output is therefore an average rate of reaction for the reactor as a whole, and is thus distinct from the specific rate 9iA which is the local rate of reaction. [Pg.51]

Conversion of ore concentrates to chemical or metallurgical fuel. The volume output is small and geographical location is unimportant. A source of chemical labor and provision for waste disposal are important considerations for this plant. [Pg.465]

When selecting the type of pacemaker, the first question should be, What is the status of the atrium and can it be paced and/or sensed The relatively unimportant contribution of AV synchrony to the cardiac output on exercise (as opposed to the increase in heart rate) should not detract from the well-established benefits of maintaining AV synchrony at rest for the prevention of hanodynamic (such as the pacemaker syndrome) and electrophysiological complications of atrial dysfunction (atrial fibrillation). One should be guided by the statement by the British Pacing and Electrophysiology Group that the atrium should be paced/sensed unless contraindicated (35). Therefore, the... [Pg.422]


See other pages where Unimportant outputs is mentioned: [Pg.158]    [Pg.203]    [Pg.21]    [Pg.157]    [Pg.45]    [Pg.16]    [Pg.66]    [Pg.310]    [Pg.125]    [Pg.462]    [Pg.32]    [Pg.316]    [Pg.4]    [Pg.279]    [Pg.338]    [Pg.75]    [Pg.212]    [Pg.76]    [Pg.92]    [Pg.162]   
See also in sourсe #XX -- [ Pg.16 ]




SEARCH



Unimportance

Unimportant

© 2024 chempedia.info