Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Optical parameter

What is striking in our model calculations is the rather good agreement of the (Up and r parameters for oqi between our optical (in the MG model) and the ESR results [7]. In fact, the ESR scattering time tESR jq-13 along the quasi onedimensional CNTs implies a a c of 10 S/cm for an [7], which is in agreement with a c = /r = 1700 S/cm evaluated from the optical parameters (Table... [Pg.103]

Such differences of the thermal IR emission spectra of compounds that consist of oxygen-containing ions and halide ions are related to the relationships between the compounds optical parameters. [Pg.173]

Microscopy. A broad definition of microscopy is the observation and measurement of optical parameters with any instrument that uses energy sources such as photons, electrons or X-rays to... [Pg.143]

The first part of the presentation will deal with the fabrication of aspheric mirrors of varying degrees of difficulty and explaining how the difficulty is related to the optical parameters of the surfaces. In general, the same difficulties arise in testing of aspheres in the same order and for the same reasons, so this chapter will serve as somewhat of an introduction to the optical testing chapter as well. [Pg.87]

We have seen how the presence of shot noise dictates some key choices minimum laser power, beam and mirror diameter, necessity to use Fabry-Perot cavities in the arms. Other noise sources will fix other important optical parameters. [Pg.321]

For the application of QDs to three-dimensional biological imaging, a large two-photon absorption cross section is required to avoid cell damage by light irradiation. For application to optoelectronics, QDs should have a large nonlinear refractive index as well as fast response. Two-photon absorption and the optical Kerr effect of QDs are third-order nonlinear optical effects, which can be evaluated from the third-order nonlinear susceptibility, or the nonlinear refractive index, y, and the nonlinear absorption coefficient, p. Experimentally, third-order nonlinear optical parameters have been examined by four-wave mixing and Z-scan experiments. [Pg.156]

A Malvern Mastersizer (Malvern Instruments Ltd, Malvern, UK) with optical parameters defined by the manufacturer s presentation code 0505 was used to determine the droplet size distribution. The measurement was made in triplicate at room temperature. Water was used to disperse the emulsion droplets. [Pg.273]

The lifetime detection techniques are self-referenced in a sense that fluorescence decay is one of the characteristics of the emitter and of its environment and does not depend upon its concentration. Moreover, the results are not sensitive to optical parameters of the instrument, so that the attenuation of the signal in the optical path does not distort it. The light scattering produces also much lesser problems, since the scattered light decays on a very fast time scale and does not interfere with fluorescence decay observed at longer times. [Pg.12]

If the measurement of the intensity of the reflected light is not available, then a second approach is employed, Thus, A and 41 are measured at a large number of wavelengths. The thickness L is estimated, perhaps from electrochemical data, and values of n and kf are then calculated at each of the wavelengths using the measured A and 4 values. The resultant values of the optical parameters are then scrutinised and retained or rejected on the basis of judgements on whether or not they fall within... [Pg.132]

This knowledge of the fluorescence emission pattern and its dependence on the optical parameters of the materials involved allows one to predict the angle at which maximum fluorescence intensity would be recorded for a particular system and to subsequently design a suitably structured platform for enhanced fluorescence capture. The design and implementation of such a platform is described in the following section. [Pg.207]

Indirect smeasurement of optical parameters AChE-biotests (TV-computer analysis)... [Pg.161]

Based on the definition, device sensitivity is related to the variation of transducing optical parameters, and thus depends on the transducing method. For the resonant wavelength shift scheme, it is expressed as... [Pg.184]

Change in the absorption coefficient is found by arranging the measurements and voxel combinations in vector-matrix form as y = Ax where y is the change in absorbance detected at each source-detector pair, A is the so called system matrix derived from Lj and x is the optical parameters of interest, namely the absorption coefficients. [Pg.350]

Figure 7.S. Collection efficiencies QllL versus z, for an objective of numerical aperture 1.4 centered on the normal to the interface. Results are given both for the objective positioned beneath the interface to collect light emitted through the glass and above the interface to collect light emitted in the water, (a) Bare glass (b) aluminum film on glass. All optical parameters are the same as in Figure 7.3. Figure 7.S. Collection efficiencies QllL versus z, for an objective of numerical aperture 1.4 centered on the normal to the interface. Results are given both for the objective positioned beneath the interface to collect light emitted through the glass and above the interface to collect light emitted in the water, (a) Bare glass (b) aluminum film on glass. All optical parameters are the same as in Figure 7.3.
Figure 7.6. Intensity emitted at supercritical angle 6 = 70° into the glass versus dipole distance z for dipoles oriented perpendicular to the interface. The solid lines show the properly normalized (fixed-power dipole) intensities for the bare glass and Al film surfaces. The dashed line shows the exponentially decaying intensity that would be obtained for bare glass by omitting the required normalization PT in Eq. (7.34). All optical parameters are the same as in Figure 7.3. Figure 7.6. Intensity emitted at supercritical angle 6 = 70° into the glass versus dipole distance z for dipoles oriented perpendicular to the interface. The solid lines show the properly normalized (fixed-power dipole) intensities for the bare glass and Al film surfaces. The dashed line shows the exponentially decaying intensity that would be obtained for bare glass by omitting the required normalization PT in Eq. (7.34). All optical parameters are the same as in Figure 7.3.
Finally, in the quantum approximation the radiation is no longer treated classically (i.e., using Maxwell s equation), and so both radiation and matter are described by quantum methods. For most of the features in the spectra of solids, this approach is not necessary and it will not be invoked. However, this approximation also leads to important aspects, such as zero-point fluctuations, which are relevant in the theory of lasers and Optical Parametic Oscillators (Chapter 3). [Pg.8]

Figure 7 Contrast transfer functions T(u) at defocus values e = -850 A, -165A and -525A. The optical parameters are from a Philips CM30/ST microscope U = 300 kV, Cs=1.15 mm, A = 70 A and a = 1.2 mrad. All the three contrast functions have a common first crossover position at u = 0.272 A. The defocus value -850 A was determined to be the correct defocus... Figure 7 Contrast transfer functions T(u) at defocus values e = -850 A, -165A and -525A. The optical parameters are from a Philips CM30/ST microscope U = 300 kV, Cs=1.15 mm, A = 70 A and a = 1.2 mrad. All the three contrast functions have a common first crossover position at u = 0.272 A. The defocus value -850 A was determined to be the correct defocus...
HREM image simulations are performed using the optical parameters of EM 420-T/EDAX Philips microscope with Cs = 1.0 mm at Scherzer defocus = -57.6 nm at a thickness of 23.3 A along [001] direction and 105.4 A along [021] direction. [Pg.432]

Phase functions can also be used to measure the size and refractive index of a microsphere, and they have been used by colloid scientists for many years to determine particle size. Ray et al. (1991a) showed that careful measurements of the phase function for an electrodynamically levitated microdroplet yield a fine structure that is nearly as sensitive to the optical parameters as are resonances. This is demonstrated in Fig. 21, which presents experimental and theoretical phase functions obtained by Ray and his coworkers for a droplet of dioctylphthalate. The experimental phase function is compared with two... [Pg.42]

Information about absolute values of electrical and optical parameters of the particle are provided by the behaviour of the steady state birefringence An versus the square of the electric field E An is given by (8) ... [Pg.35]

In regard to Equation (5.4), we have to note that without the above mentioned assumptions the nonlinearities will contain weighting factors that are proportional to the corresponding wave-vector mismatch and inversely proportional to refractive index, thus suggesting that the THG signal is sensitive to the refractive index interface(s) as well. In order to differentiate between contrast mechanisms in THG imaging of soft tissue materials it would be important to know the relationships of the corresponding linear and nonlinear optical parameters. A nonlinear optical... [Pg.121]

Waggoner, A. P., and R. J. Charlson, Measurements of Aerosol Optical Parameters, in Fine Particles Aerosol Generation, Measurement, Sampling, and Analysis (B. Y. H. Liu, Ed.), pp. 511-533, Academic Press, New York, 1976. [Pg.434]


See other pages where Optical parameter is mentioned: [Pg.81]    [Pg.213]    [Pg.346]    [Pg.159]    [Pg.138]    [Pg.201]    [Pg.202]    [Pg.267]    [Pg.267]    [Pg.372]    [Pg.387]    [Pg.15]    [Pg.160]    [Pg.229]    [Pg.223]    [Pg.178]    [Pg.183]    [Pg.486]    [Pg.548]    [Pg.519]    [Pg.236]    [Pg.306]    [Pg.169]    [Pg.43]    [Pg.47]    [Pg.6]    [Pg.116]    [Pg.284]    [Pg.98]   
See also in sourсe #XX -- [ Pg.111 ]

See also in sourсe #XX -- [ Pg.1037 ]




SEARCH



Calculating Optical Parameters

Electro-optical parameters

Nonlinear optical parameters

Optical configuration parameter

Optical order parameter

Optical parameter instrumentation

Optical spectra molecular parameters from

Raman electro-optical parameters

Relevant Parameters for an Efficient All Optical Poling

The Optical Rotation Parameter

Zero-order electro-optical parameters

© 2024 chempedia.info