Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Multicharged

Normally, a range of values for n is found, each molecule (M) giving a series of multicharged ions. For example, a series... [Pg.57]

This last m/z value is easy to measure accurately, and, if its relationship to the true mass is known (n = 10), then the true mass can be measured very accurately. The multicharged ions have typical m/z values of <3000 Da, which means that conventional quadrupole or magnetic-sector analyzers can be used for mass measurement. Actually, the spectrum consists of a series of multicharged protonated molecular ions [M + nWY for each component present in the sample. Each ion in the series differs by plus and minus one charge from adjacent ions ([M + uH] + n -an integer series for example, 1, 2, 3,. .., etc.). Mathematical transformation of the spectrum produces a true molecular mass profile of the sample (Figure 40.5). [Pg.291]

This inlet/ion source is a simple system with no moving parts and yields many ions from the original dissolved sample. Even more attractive is the tendency for electrospray to produce multicharged ions, a benefit that makes accurate measurement of large relative molecular masses much easier. [Pg.390]

When multicharged ions are formed, the simple rule of thumb used widely in mass spectrometry that m/z = m because, usually, z = 1 no longer applies for z > 1 then m/z < m, and the apparent mass of an ion is much smaller than its true mass. Accurate mass measurement is much easier at low mass than at high, and the small m/z values, corresponding to high mass with multiple charges, yield accurate values for the high mass. [Pg.390]

Electrospray ionization (ESI) produces a series of multicharged ions that can be transformed into an accurate molecular mass for proteins with masses of tens of thousands. [Pg.417]

In accordance with previous investigations [8,9], Aese experiments have shown a quite different behaviour for N (ls )than for other multicharged ions such as the isoelectronic ion [10. The single-electron capture process has been shown to be dominant on the n = 3 levels and in particular on the 3s level for collision energies lower than 50 keV. A high probability of double capture has also been observed characterized by an intense peak at X = 76.5 nm attributed to the 2s > 2s 2p P transition [4,5,7]. Furthermore,... [Pg.333]

This work provides an accurate and complete treatment of the collision of a multicharged... [Pg.346]

ESI is also able to ionize not only small but also elephant molecules. In this case multicharged ions are produced (see Section 2.6.2.2). A typical ESI spectrum of a large molecule is shown in Figure 2.21. [Pg.69]

Onda found a standard deviation of 0.052J./mol for his complete set of data, including multicharged ions. These correlations thus provide a coefficient for gases in ammonium bicarbonate that may be in error by more than 0.05 Jl/mol Onda s coefficients for gases in ammonium hydrosulfide are of unknown origin and accuracy, and coefficients for ammonium carbamate are not provided. In short, this type of correlation does not provide the needed information. [Pg.117]

In summary, the overall successful effect has been assigned to the fact that any pretreatment of either the electrode surface (use of promoters, use of specific carbon electrodes, with the eventual generation of functional COO groups) or the solutions (addition of multicharged cationic species, proper choice of pH) creates at the bare electroinactive surface more and more specific microscopic active sites able to favour the exchange of electrons with proteins.10 This means that, in the absence of proper pretreatments, the electrode surface does not possess specific sites... [Pg.549]

Avoid CMP chemistry that involves multicharged cations. Such chemicals compress the double charge layer and activate slurry agglomeration and process defectivity. Ions such as Al and Fe may initiate agglomeration and scratching at concentrations as low as lO to 10 M. [Pg.31]

QED CALCULATION OL HEAVY MULTICHARGED IONS WITH ACCOUNT EOR CORRELATION, RADIATIVE AND NUCLEAR EEEECTS... [Pg.285]

Detailed analysis of the VP and SE energy eontributions shows that for ions with small Z the QED eontribution is not signifieant, but with growth of Z (Z > 40) the QED contribution becomes very important. Moreover, for heavy and superheavy ions its role is of main importance. Now let us consider the role of the nuelear finite-size effeet. As calculations show, for multicharged ions with Z < 20 its contribution is very small, but for ions with Z > 70 it can equal the vacuum polarization contribution. In Table 3 there are displayed the results of calculations for the nuelear eorrection to the energy of low transitions for Li-like ions. Our calculations also show that a variation of the nuelear radius by a... [Pg.295]

At equilibrium, intact proteins in solutions exist in multiply charged states since they have many proton accepting sites. ESI mass spectrum of the multicharged protein is converted to the actual protein mass by a specific software. [Pg.109]

Not suitable for multicharged compounds with more than 2 charges... [Pg.709]

Multicharged species require interpretation and mathematical transformation... [Pg.711]


See other pages where Multicharged is mentioned: [Pg.55]    [Pg.57]    [Pg.60]    [Pg.60]    [Pg.291]    [Pg.192]    [Pg.321]    [Pg.339]    [Pg.346]    [Pg.93]    [Pg.351]    [Pg.45]    [Pg.71]    [Pg.50]    [Pg.206]    [Pg.198]    [Pg.201]    [Pg.144]    [Pg.211]    [Pg.59]    [Pg.693]    [Pg.287]    [Pg.289]    [Pg.291]    [Pg.293]    [Pg.295]    [Pg.297]    [Pg.300]    [Pg.710]    [Pg.143]   
See also in sourсe #XX -- [ Pg.57 ]

See also in sourсe #XX -- [ Pg.57 ]




SEARCH



Determination of molecular masses from multicharged ions

Electrospray ionization multicharged ions

Ions, multicharged

© 2024 chempedia.info