Mixer modeling

Multiply K by the empty-pipe pressure drop to obtain the pressure drop eaused by the Kenies mixer model installation. The theoretieal horsepower required by the Kenies mixer is determined by... [Pg.608]

The correct number of Kenies Mixer models for blending applications... [Pg.609]

What Kenics Mixer model of 3-in. Schedule 40 is required to process a Newtonian fluid with a viscosity of 150,000 cP, a density of 60 Ib/ft, and a flowrate of 650 Ib/hr What is the pressure drop (AP) and theoretical horsepower ... [Pg.610]

From Table 7-10, the lengtli of tlie Kenies mixer model is L = 2.82 ft. Therefore, the length of four modules is (i.e., the length of model 6 mixer = 2.82 ft) ... [Pg.612]

Determine which 2-in. Schedule 40 mixer model is required to process water-like fluids at a flowrate of 10 gpm. What is the required theoretical horsepower (Data viscosity = 1 cP Density = 62.4 Ib /ft assume = 0.00015 ft)... [Pg.613]

A model must be introduced to simulate fast chemical reactions, for example, flamelet, or turbulent mixer model (TMM), presumed mapping. Rodney Eox describes many proposed models in his book [23]. Many of these use a probability density function to describe the concentration variations. One model that gives reasonably good results for a wide range of non-premixed reactions is the TMM model by Baldyga and Bourne [24]. In this model, the variance of the concentration fluctuations is separated into three scales corresponding to large, intermediate, and small turbulent eddies. [Pg.344]

Baldyga, J. (1989). Turbulent mixer model with application to homogeneous, instantaneous chemical reactions. Chemical Engineering Science 44, 1175-1182. [Pg.407]

Mechanical stirring is adequate for a 50-g scale, as described herein, and magnetic stirring 1s sufficient for a 5-g scale. The submitters ran the procedure on a 200-g scale, and found that use of a Vlbro-mixer Is essential to obtain satisfactory oxygenation of the reaction mixture. The Vlbro-mixer model E-l was supplied by Chemap AG, Alte Landstr. 415, CH-8708, Mannedorf, Switzerland. [Pg.28]

Mixing sequence (using a small Hobart mixer, model N-50, 80... [Pg.182]

Splitters and mixers models are also needed to represent the proposed superstructure. [Pg.165]

In order to realize the Polyamide-6 scenario problem presented in Subsect. 5.3.2, a process description is defined using ModKit+. The elementary models for the reaction section, the separator, and the extruder, already imported into ROME, are added as submodels of the overall process. Further, a mixer is defined in order to combine feed and recycle streams corresponding mass balances are added to the elementary mixer model. After this modeling activity the model repository ROME contains all necessary models for the overall Polyamide-6 process. The model behavior is partly described by equations (for the mixer) and partly described by model implementations in the form of input files for the modeling tools Aspen Plus, gPROMS, and MOREX. [Pg.488]

The solution is then whipped at speed III (260 rpm) for 10 minutes in a Hobart Mixer (model N - 50) using a wire whisk. Immediately afterwards, ten samples of 10 ml are transferred to an aluminium tray at separate positions by means of a syringe. [Pg.139]

Apparatus. High performance liquid chromatographic separations were achieved on a binary gradient microbore HPLC systems primary pump (A) Model 305, secondary pump (B) Model 306, monomclric module Model 805, and a dynamic mixer Model 811C from Gilson Inc. (Middleton. Wl). Sample injections were achieved with a 20 pL loop on a Model EQ-36 injection valve from Valeo Instruments Co. Inc. (Houston, TX). A stainless steel Y-splitter also from Valeo was used in order to achieve a post-column split of the mobile phase Dow to the CLND. A Supelcosil LC-18S analytical HPLC column was purchased from SUPELCO Inc. (Bellefonte. PA). The Y-splitter was attached to the analytical column by a SLIPFREE connector, available from Keystone Scientific Inc. (Bellefonte, PA). Analyses of nor-dihydrocapsaicin, capsaicin and dihydrocapsaicin in spices as well... [Pg.57]

Perfect Mixer" model this t) e of model represents an immediate and uniform mixture of the entering fluid. The impulsive response of such a system is the exponential Shape (Fig. 4-10) and spells ... [Pg.176]

Preparation of the composites reinforced with 10 wt% and 20 wt% of different types of coconut fiber (treated and imtreated) as reinforcement of PP The composites were prepared in batches of 50 g in a thermokinetic mixer (model MH - 50H) rotating at 5250 rpm. [Pg.109]

The pretreated palm fibers were mixed with the polymeric matrix (HOPE) in a ther-mokinetic mixer model MH-50H, with the speed rate kept at 5250 rpm, in which fibers were responsible for 5 and 20 wt% of the composition. [Pg.217]

The left-hand side of Figure 6.10 shows the laminar static mixer model consisting of 3D geometry with three twisted blades of alternating rotations. The right-hand side of Figure 6.10 shows the computational mesh of the same laminar static mixer model. [Pg.227]

Figure 3.3 Pressure drop versus total volume rate for various slit plate mixer models LH2, LH25, and LH1000 with the configuration of mixing plates (MPs) and aperture plates (APs). Figure 3.3 Pressure drop versus total volume rate for various slit plate mixer models LH2, LH25, and LH1000 with the configuration of mixing plates (MPs) and aperture plates (APs).
The mixer was Moriyama internal mixer, model D3-75, with a 3 litre capacity. The fill factor was 0.7, and the rotor speeds were 72.2 rpm for the front rotor and 52.1 rpm for the back rotor. Also, a laboratory size Banbury mixer was used to assure the similarity of mixing performance. [Pg.342]

The HDPE, cellulose fibres, and HDPE-MA were blended at the setting temperature of 140 °C and 60 rpm for 10 minutes using a batch mixer (Model 6, C.W.Brabender). After the compounding, the melt blends were cooled down to room temperature. The solidified blends were granulated using a granulator (S-10-9, C.W. Brabender). [Pg.2604]


See other pages where Mixer modeling is mentioned: [Pg.185]    [Pg.281]    [Pg.266]    [Pg.1089]    [Pg.129]    [Pg.113]    [Pg.177]    [Pg.58]    [Pg.281]    [Pg.303]    [Pg.953]    [Pg.63]   
See also in sourсe #XX -- [ Pg.2 ]