Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mixer drivers

Fig. 12. The phase shifter/mixer unit. For each of the four rf channels the TTL logic box contains two monoflops that may activate a mixer-driver through a triple OR gate. The third input of each OR gate accepts gate pulses from the pulse programmer whose lengths are specified by software on a raster of 100 ns. The two monoflops are fired by needles from the pulse programmer and allow finely adjusted rf pulses of duration 0.3-1.5 and 0.5-3 /us, respectively, to be generated. Fig. 12. The phase shifter/mixer unit. For each of the four rf channels the TTL logic box contains two monoflops that may activate a mixer-driver through a triple OR gate. The third input of each OR gate accepts gate pulses from the pulse programmer whose lengths are specified by software on a raster of 100 ns. The two monoflops are fired by needles from the pulse programmer and allow finely adjusted rf pulses of duration 0.3-1.5 and 0.5-3 /us, respectively, to be generated.
Fig. 15. The pulse shaper. The gate is a DMF2A 5-1000 double-balanced mixer from Merrimac. R = 300 fl, R = 18 fl, and C = 270 pF. The bottom part shows how a properly delayed, shortened dc pulse is generated. The signal at TTL in is any of the +x, x, -t-y, or -y mixer-driver pulses generated in the phase shifter/mixer unit. TTL out is used to drive the switch in the preamplifier unit into its off state. Fig. 15. The pulse shaper. The gate is a DMF2A 5-1000 double-balanced mixer from Merrimac. R = 300 fl, R = 18 fl, and C = 270 pF. The bottom part shows how a properly delayed, shortened dc pulse is generated. The signal at TTL in is any of the +x, x, -t-y, or -y mixer-driver pulses generated in the phase shifter/mixer unit. TTL out is used to drive the switch in the preamplifier unit into its off state.
Mixer a device for carrying out a mixing operation and which generally inclusively refers to an impeller, driver, baffle, and vessel combination. [Pg.454]

Most mixers are driven by electric motons, or in some cases by mechanical turbines, with gears ratioed to give the proper performance speed of the impeller. A variable or 2-speed driver or gear system often proves worth the extra cost, since it is difficult to predict the exact speed requirements for some new installations. This is particu-... [Pg.306]

Glass Impinger, flow rate = 0.014 m /min. tractor mounted near breathing zone of driver. Samples collected from work zones of 4 mixer-loader applicators (F, G, H, I). [Pg.47]

T excreted by the 21 forest workers in two exposures under typical field conditions. The highest dose was received by mixers who handled the herbicide concentrate, followed by applicators using backpack sprayers, spray tractor drivers, helicopter... [Pg.148]

Categorized by work duties, mixers (those handling concentrate) received the highest internal dose of 2,4,5-T, followed in order by backpack sprayers, mist blower drivers, helicopter pilots, supervisors, and flagmen for the helicopter operation. One helicopter pilot excreted considerably less 2,4,5-T in his urine than did the other pilot. This difference appeared to be related to the fact that the second pilot routinely checked and unplugged nozzles at each fill-up time. In... [Pg.326]

In addition, the following specific chemical engineering drivers may govern the decision to use a micro or microstructured mixer ... [Pg.3]

Table IX presents the exposure of persons Involved In the ground application of mancozeb by an alrblast sprayer to a tomato field In Ohio. Mixer-loaders again experienced exposure to mancozeb with forearms predominating (2856-3485 iig/body area). Tractor driver—applicators did not experience much exposure, but forearms did range from nondetectable to 1090 yg/body area. Home gardeners using a compressed air sprayer In a homeyard setting experienced little exposure to mancozeb (Table X), except for their ankle and thigh pads (nondetectable-4290 yg/body area). Table IX presents the exposure of persons Involved In the ground application of mancozeb by an alrblast sprayer to a tomato field In Ohio. Mixer-loaders again experienced exposure to mancozeb with forearms predominating (2856-3485 iig/body area). Tractor driver—applicators did not experience much exposure, but forearms did range from nondetectable to 1090 yg/body area. Home gardeners using a compressed air sprayer In a homeyard setting experienced little exposure to mancozeb (Table X), except for their ankle and thigh pads (nondetectable-4290 yg/body area).
Table IX. Exposure of Mixer-Loaders and Tractor Driver-Applicator to Mancozeb and ETU During the... Table IX. Exposure of Mixer-Loaders and Tractor Driver-Applicator to Mancozeb and ETU During the...
Although density is essentially a static property, absolute (or dynamic) viscosity is a dynamic property and tends to reduce in magnitude as the shear rate in a pipeline increases. Thus, engineers have had to define different forms of viscosity over the years, everything from dynamic viscosity, to kinematic viscosity, to effective pipeline viscosity. The effective pipeline viscosity will be discussed in detail in Chapters 3, 4, and 5. In this chapter, the reader is introduced to basic concepts of the mixture of slurry in a stationary state. This is effectively what the pump, or a mixer, might see at the start-up of a plant. As is often the case, when the driver cannot deliver enough torque to overcome the absolute (or dynamic) viscosity, the operator is forced to dilute the slurry mixture. [Pg.36]

Once you have verified that your hardware is properly configured, the next step is to find the mixer properties for the sound card. The drivers that come with the card often allow you to select the type of input device(s) used for recording and set the gain. Unfortunately, this can be different for every sound card. The following procedure is fairly generic for a large number of Windows sound cards. [Pg.106]

In May, an accident in Montana caused by a tyre blowout on a concrete mixer tmck resulted in the death of two women. A lawsuit is being filed on behalf of the victims husbands seeking unspecified damages for negligence and product liability. The retreaded tyre was fitted on the steer axle of the truck and when the tyre blew, the driver lost control of the vehicle and it collided head-on with the women s car. The attorneys handling the case hope it will spur efforts nationwide to get retreaded tyres banned from use on commercial vehicles steer axles. [Pg.36]


See other pages where Mixer drivers is mentioned: [Pg.432]    [Pg.319]    [Pg.432]    [Pg.319]    [Pg.324]    [Pg.324]    [Pg.553]    [Pg.552]    [Pg.1]    [Pg.61]    [Pg.143]    [Pg.146]    [Pg.322]    [Pg.428]    [Pg.282]    [Pg.31]    [Pg.1]    [Pg.61]    [Pg.1]    [Pg.59]    [Pg.4]    [Pg.61]    [Pg.61]    [Pg.2360]    [Pg.18]    [Pg.76]    [Pg.125]    [Pg.2343]    [Pg.118]    [Pg.201]    [Pg.202]    [Pg.420]    [Pg.265]    [Pg.342]   
See also in sourсe #XX -- [ Pg.2 ]




SEARCH



Driver

© 2024 chempedia.info