Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mitex membrane

Three commercially available filtering media were evaluated for the collection of airborne particulates of the organoarsenical compounds. These were cellulose ester, Fluoropore, and Mitex membrane filters. The evaluation was based on the following requirements l) the collection medium must quantitatively collect the particulates 2) the collection medium must be capable of. retaining the compounds without loss or chemical change before analysis 3) the collected species must be extracted quantitatively from the collection medium for analysis and b) the method must be efficient at temperatures up to 50°C and a relative humidity of... [Pg.384]

The GPC instrumentation and GPC procedures used here are the same as described earlier (I) but with slight alterations. The Kroeger HAK-1 pads furnished with the pressure filter were replaced by Millipore 5-/x Mitex membranes to reduce changes in solution concentrations arising from adsorption of the solute on the fibrous material of the pad. When retention of eluted fractions was desired, two shallow aluminum pans filled with tetrahydrofuran (THF) were placed in the syphon box, and then the door was closed and latched. The saturation of the enclosed air space by THF vapor minimized evaporation of the solution during drop formation, drop fall, and retention of fraction in the syphon. The possibility of diluting the sample solution when charging the sample loop was... [Pg.185]

The nature of the supporting membrane also plays an important role in the performance of supporting ionic liquid membranes. In this context, de los Rios et al. [3] nsed two polymeric membranes, nylon and mitex, as supporting membranes. Nylon membrane was a hydrophilic polyamide membrane with a pore size of 0.45 pm and a thickness of 170 pm. Mitex membrane was a hydrophobic polytetrafluoroethylene membrane with a pore size of 10 pm and a thickness of 130 pm. It was observed that less ionic liquid was absorbed into the mitex membranes, which was explained by the different textural properties and the high hydrophobic character of these membranes, which probably restrict interaction with the hydrophilic ionic liquids used [27]. [Pg.279]

Three filtering media commercially available from Millipore Corporation were evaluated for the collection of airborne particulates of the organoarsenical compounds. These were (l) cellulose ester membranes (2) Fluoropore and (3) Mitex. The cellulose ester membrane filters (0.8 ym pore size) are the standard Millipore filters used for aerosol sampling and consist of a mixture of cellulose nitrate and cellulose acetate. The Fluoropore filters are made of Teflon (PTFE) and are bonded to a polyethylene net. Fluoropore filters with a pore size of 1.0 ym were selected for this study. [Pg.387]


See other pages where Mitex membrane is mentioned: [Pg.384]   
See also in sourсe #XX -- [ Pg.279 ]




SEARCH