Figure 23. Morphology of rat aortic smooth muscle cells 48 h after seeding on high-density (A, C, E) and low-density (B, D, F) polyethylene. A, B pristine polymers, C, D plasma-irradiated polymers, E, F polymers irradiated with plasma and subsequently grafted with glycine. Cell membrane stained with Texas Red C2-maleimide, the nuclei counterstained withHoechst 33342. Olympus IX 50 microscope, digital camera DP 70. Bar=200 pm. Figure 23. Morphology of rat aortic smooth muscle cells 48 h after seeding on high-density (A, C, E) and low-density (B, D, F) polyethylene. A, B pristine polymers, C, D plasma-irradiated polymers, E, F polymers irradiated with plasma and subsequently grafted with glycine. Cell membrane stained with Texas Red C2-maleimide, the nuclei counterstained withHoechst 33342. Olympus IX 50 microscope, digital camera DP 70. Bar=200 pm.
Microprobe mappings and measurements of minor element concentrations were obtained at the Analytical Centre of the Mineralogical Laboratory of the Natural History Museum (London) using a CAMECA SX 50 instrument equipped with four wave-length dispersive detectors. Atomic force observations were carried out with a Dimension 3000 microscope (Digital Instrument) using the... [Pg.88]

The thickness of the synthesized brashes was determined by means of ellipsometry performed on a COMPEL Automatic Ellipsometer (InOm Tech, Inc.) at a fixed 70o incidence angle. Refractive index for all polymers was asstrmed to be 1.5. Strrface characterization was performed by Scanning Probe Microscopy (SPM) in tapping mode on a Dimension 3100 microscope (Digital Irrstruments, Veeco ). Static contact angle measurements were made using a... [Pg.218]

Nanoscale adhesion and friction of PDMS films were quantified by AFM using a Dimension 3000 microscope (Digital Instruments) in contact mode with... [Pg.61]

Thin section Scanner Microscope + digital camera... [Pg.27]

Single-walled carbon nanotubes (SWNTs) obtained in the Rice University, Houston, were investigated in high resolution mode (0.335 nm) using a Philips 420 transmission electron microscope. Digital images were captured at the atomic lev-... [Pg.229]

The STATPack consultation process involves capturing macroscopic and/or microscopic digital images of culfure samples, or possibly original clinical specimens, and sending them electronically to experts at state public health laboratories for consulfafion. STATPack... [Pg.371]

Infrared spectra of hybrid thin films were measured by using a Jasco Model FTIR 410 spectrophotometer. An atomic force microscope (Digital Instrument, Inc., Model DI 5000 AFM) was used to probe the surface morphology of the... [Pg.310]

AFM measurement was performed by using scanning tunneling microscope (Digital Instruments, Inc. Nanoscope-II). [Pg.63]

Structural studies of silica sols films were carried out using atomic force microscopy (AFM) method. The films, were prepared by casting solutions on a rapidly spinned substrate - mica. The film surface was scanned at room temperature and atmospheric pressure using a Nanoscope III atomic-force microscope (Digital Instruments, California). Silicon tips with a constant of elasticity of 50 N/m and a tip radius smaller that 10 nm, vibrated at a resonance frequency of about 320 kHz, were used. [Pg.505]

Microscope observations were carried out using a microscope (Digital microscope VHX-900, VH-ZOOR, Keyence Co., Osaka, Japan). [Pg.287]