Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mechanical orientation

Because of the rotation of the N—N bond, X-500 is considerably more flexible than the polyamides discussed above. A higher polymer volume fraction is required for an anisotropic phase to appear. In solution, the X-500 polymer is not anisotropic at rest but becomes so when sheared. The characteristic viscosity anomaly which occurs at the onset of Hquid crystal formation appears only at higher shear rates for X-500. The critical volume fraction ( ) shifts to lower polymer concentrations under conditions of greater shear (32). The mechanical orientation that is necessary for Hquid crystal formation must occur during the spinning process which enhances the alignment of the macromolecules. [Pg.202]

Mechanical orienting tool A device to orient deflecting tools without the use of subsurface surveying instruments. [Pg.1081]

Fig. 2 Mechanically oriented bilayer samples as a membrane model for ssNMR. (a) Illustration of the hydrated lipid bilayers with MAPs embedded, the glass supports, and the insulating wrapping, (b) A real sample consists of 15 stacked glass slides, (c) Schematic solid-state 19F-NMR lineshapes from an oriented CF3-labelled peptide (red), and the corresponding powder lineshape from a non-oriented sample (grey), (d) Illustration of typical orientational defects in real samples - the sources of powder contribution in the spectra... Fig. 2 Mechanically oriented bilayer samples as a membrane model for ssNMR. (a) Illustration of the hydrated lipid bilayers with MAPs embedded, the glass supports, and the insulating wrapping, (b) A real sample consists of 15 stacked glass slides, (c) Schematic solid-state 19F-NMR lineshapes from an oriented CF3-labelled peptide (red), and the corresponding powder lineshape from a non-oriented sample (grey), (d) Illustration of typical orientational defects in real samples - the sources of powder contribution in the spectra...
For the orientation-based structure analysis of MAPs, uniformly oriented lipid bilayers are typically prepared on solid supports as illustrated in Fig. 2 [23, 47, 55]. These mechanically oriented membranes are advantageous for static ssNMR experiments, as they provide a robust way to orient a sample with any desired lipid composition, peptide concentration, and at any desired temperature. The lipids... [Pg.96]

Four chapters towards the end of the book diverge from the other mechanism-oriented chapters. They have a strong biochemical theme and will undoubtedly overlap with what may be taught separately by biochemists. These topics are approached here from a chemical viewpoint, using the same structural and mechanistic principles developed earlier, and should provide an alternative perspective. It is probable that some of the material described will not be required during the first 2 years of study, but it could sow the seeds for more detailed work later in the course. [Pg.711]

ORDERED TER Bl MECHANISM ORDERED TER TER MECHANISM ORDERED UNI Bl MECHANISM Oriented diffusion,... [Pg.767]

Table 2.1 summarises the various reagents we have mentioned (and some we haven t). Full details of mechanisms, orientation and applications appear in Clayden chapter 22. [Pg.11]

Some report that over 50 percent of the urea-formaldehyde resins consumed went into particleboard. This is brought out because there may be a shift away from urea resin for certain types of oriented particleboard used in structural plywood constructions. Historically, particleboard has been used for inner plies as previously mentioned in some hardwood plywood. There is now one plant in production in Idaho which produces mechanically oriented strand particleboard for use specifically as core for softwood plywood production. It is anticipated that this trend to some degree will increase in the future, and phenolic resins appear to be the mechanism with which this particleboard will be bonded. [Pg.283]

B. Linear and Cubic Dynamic Susceptibilities of a Dipolar Suspension Effect of Mechanical Orientation... [Pg.553]

Tier-3 The tier with complex specific approaches. In the third tier, a mechanistic or semimechanistic model is adopted in addition to an empirical, statistical-modeling part. For example, the use of SSDs is a statistically oriented approach, but the use of this model can be refined by using mechanism-oriented insights (i.e., by considering separate species groups that are inherently more sensitive than others for the individual substance or the components of a mixture). In this way, the approach becomes more complex to handle, but likely also yields more accurate results than the moderately simple generic approach. [Pg.301]

As this chapter covers the most important class of thiazoles by the number of products and references, it is virtually impossible to treat in detail every class of derivatives. The mechanism-oriented approach to reactivity and the detailed tables at the end of the chapter should, however, permit easy extrapolation to most other compounds. [Pg.314]

Having quantitatively accounted for electrophilic effects of solvent, discrepancies between calculated and observed rates of solvolysis could indicate fruitful areas for mechanism-oriented research. However, such correlations would still not account for effects of ground state solvation or the temperature dependence of... [Pg.61]

Natural birefringence is mainly found in crystalline substances artificial birefringence is normally based on mechanical orientation, either in the solid or in the liquid state stretch and flow orientation, respectively. Melts and solutions may show birefringence, caused by ... [Pg.299]

The transition moment directions of some of the absorption bands of PBLG in liquid crystalline state have been investigated in a CaF2 cell by means of the infra-red dichroic ratio (56). All the transition moment directions measured at 1 °C are very similar to those observed 32) on mechanically oriented films of PBLG (Table 2), verifying that all the polymer molecules present a parallel or nearly parallel orientation in the molecular cluster and that the main chain and the side chains of the polymer molecule are fixed as in the solid film. No significant difference is observed between the systems of solution testing. The orientation of the solvent molecules (methylene moletules) is detected in an electric field in accordance with the NMR observation (56). [Pg.86]

In the molecular cluster of TOLG the mm chain and the side chains of the p(dypeptide molecule orient in a similar way as in the mechanically oriented film however, the rotation of the side chains becomes marked at high temperature, say... [Pg.104]

Chiral lc-polymers can be prepared by a proper functionalization of lc-polymers with chiral and reactive groups. These elastomers are interesting, because they combine the mechanical orientability of achiral lc-elastomers with the properties of chiral lc-phases, e.g. the ferroelectric properties of the chiral smectic C phase. The synthesis of these elastomers was very complicated so far, but the use of lc-polymers, which are functionalized with hydroxyl-groups, has opened an easy access to these systems. Also photocrosslinkable chiral lc-polymers can be prepared via this route. [Pg.207]


See other pages where Mechanical orientation is mentioned: [Pg.44]    [Pg.89]    [Pg.76]    [Pg.101]    [Pg.329]    [Pg.461]    [Pg.200]    [Pg.497]    [Pg.167]    [Pg.262]    [Pg.541]    [Pg.401]    [Pg.55]    [Pg.248]    [Pg.236]    [Pg.189]    [Pg.29]    [Pg.420]    [Pg.607]    [Pg.307]    [Pg.299]    [Pg.66]    [Pg.549]    [Pg.103]    [Pg.6]   
See also in sourсe #XX -- [ Pg.181 ]




SEARCH



Orientability, mechanical

© 2024 chempedia.info