MALDI Mass analyzer

For solids, there is now a very wide range of inlet and ionization opportunities, so most types of solids can be examined, either neat or in solution. However, the inlet/ionization methods are often not simply interchangeable, even if they use the same mass analyzer. Thus a direct-insertion probe will normally be used with El or Cl (and desorption chemical ionization, DCl) methods of ionization. An LC is used with ES or APCI for solutions, and nebulizers can be used with plasma torches for other solutions. MALDI or laser ablation are used for direct analysis of solids. [Pg.280]

Mass-Analyzed Laser Desorption Ionization (MALDI)... [Pg.284]

With the identities and amounts of amino acids known, the peptide is sequenced to find out in what order the amino acids are linked together. Much peptide sequencing is now done by mass spectrometry, using either electrospray ionization (ESI) or matrix-assisted laser desorption ionization (MALDI) linked to a time-of-flight (TOF) mass analyzer, as described in Section 12.4. Also in common use is a chemical method of peptide sequencing called the Edman degradation. [Pg.1031]

Different strains of E. coli have unique fingerprints when analyzed by MALDI mass spectrometry of whole cells, as illustrated by the spectra of Figure 9.3. Many peaks appear at the same masses in all of the spectra, with only modest intensity variations. A few peaks also vary dramatically in intensity for these four strains. We expect the spectra to be similar, since all the strains are laboratory derivatives of the single E. coli strain, K-12. Genetic modifications can, and most likely do, affect biological functions such as tran-... [Pg.188]

The compatibility is excellent with continuous ion sources such as ESI, dynamic SIMS, CF-FAB, ICP, El, Cl, etc. Sector instalments are not well-suited for pulsed ionization methods, although there are examples where MALDI sources have been utilized [225-229]. Sector instruments are usually larger and more expensive than other mass analyzers, such as TOFs, quadrupole filters, and traps. [Pg.49]

MALDI generated a great demand for a mass analyzer ideally suited to be used in conjunction with a pulsed ion source and capable of transmitting ions of extremely high mass up to several 10 u. [24] Since then, the performance of TOF instruments has tremendously increased. [25,26] TOF analyzers were adapted for use with other ionization methods and are now even strong competitors to the well-established magnetic sector instruments in many applications. [25,27]... [Pg.114]

Laser desorption intrinsically is a pulsed ionization process, which is therefore ideally combined with time-of-flight (TOF) analyzers (Chap. 4.2). [16,49] Ever since the first MALDI experiments, MALDI and TOF have been forming a unit, and the majority of MALDI applications are MALDI-TOF measurements. Vice versa, it was the success of MALDI that pushed forth the tremendous delevopment of TOF mass analyzers. More recently, MALDI has also been adapted to orthogonal acceleration TOF analyzers. [147]... [Pg.433]

The use of MALDI for the analysis of small molecules was recently reported. Particularly attractive is the coupling of a MALDI source with a triple quadrupole mass analyzer for quantitative analysis in the selected reaction monitoring (SRM) mode due to very high analysis speed. [Pg.23]

With soft ionization techniques such as MALDI, ions of m/z 200000 can be routinely detected. The mass range is mainly limited by the fact that with the detector the response decreases with increasing m/z of the ions. The mass resolution of a TOF mass analyzer is relatively poor (unit mass resolution and less) and is affected by factors that create a distribution in the flight time of ions with the same m/z. The simplest way to increase the mass resolution is to increase the length of flight tube or to reduce the kinetic energy spread of the ions leaving the source. [Pg.33]


See other pages where MALDI Mass analyzer is mentioned: [Pg.92]    [Pg.57]    [Pg.92]    [Pg.57]    [Pg.136]    [Pg.284]    [Pg.1029]    [Pg.376]    [Pg.27]    [Pg.40]    [Pg.47]    [Pg.134]    [Pg.197]    [Pg.303]    [Pg.334]    [Pg.35]    [Pg.37]    [Pg.191]    [Pg.402]    [Pg.402]    [Pg.341]    [Pg.702]    [Pg.168]    [Pg.230]    [Pg.231]    [Pg.403]    [Pg.411]    [Pg.431]    [Pg.433]    [Pg.155]    [Pg.149]    [Pg.152]    [Pg.22]    [Pg.24]    [Pg.34]    [Pg.444]    [Pg.683]    [Pg.685]    [Pg.687]   