Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Magnetic field selection

The following examples represent the importance of the impulse response for the comparison of different magnetic field sensors. For presentation in this paper only one data curve per method is selected and compared. The determined signals and the path x are related in the same way like in the previous chapter. [Pg.370]

A very weak peak at 348 mn is the 4 origin. Since the upper state here has two quanta of v, its vibrational syimnetry is A and the vibronic syimnetry is so it is forbidden by electric dipole selection rules. It is actually observed here due to a magnetic dipole transition [21]. By magnetic dipole selection rules the A2- A, electronic transition is allowed for light with its magnetic field polarized in the z direction. It is seen here as having about 1 % of the intensity of the syimnetry-forbidden electric dipole transition made allowed by... [Pg.1139]

The transition between levels coupled by the oscillating magnetic field B corresponds to the absorption of the energy required to reorient the electron magnetic moment in a magnetic field. EPR measurements are a study of the transitions between electronic Zeeman levels with A = 1 (the selection rule for EPR). [Pg.1551]

In absorption spectroscopy a beam of electromagnetic radiation passes through a sample. Much of the radiation is transmitted without a loss in intensity. At selected frequencies, however, the radiation s intensity is attenuated. This process of attenuation is called absorption. Two general requirements must be met if an analyte is to absorb electromagnetic radiation. The first requirement is that there must be a mechanism by which the radiation s electric field or magnetic field interacts with the analyte. For ultraviolet and visible radiation, this interaction involves the electronic energy of valence electrons. A chemical bond s vibrational energy is altered by the absorbance of infrared radiation. A more detailed treatment of this interaction, and its importance in deter-... [Pg.380]

Alternatively, ions of any one selected m/z value can be chosen by holding the magnetic field steady at the correct strength required to pass only the desired ions any other ions are lost to the walls of the instrument. The selected ions pass through the gas cell and are detected in the singlepoint ion collector. If there is a pressure of a neutral gas such as argon or helium in the gas cell, then ion-molecule collisions occur, with decomposition of some of the selected incident ions. This is the MS/MS mode. However, without the orthogonal TOF section, since there is no further separation by m/z value, the new ions produced in the gas cell would not be separated into individual m/z values before they reached the detector. Before the MS/MS mode can be used, the instrument must be operated in its hybrid state, as discussed below. [Pg.159]

The selective redection of chiral nematic Hquid crystals has also been used to develop sensors for pressure, radiation (especially infrared), wind shear over surfaces, stmctural fatigue, and foreign chemical vapor (48). Other types of Hquid crystals have been used to make sensors to measure both electric and magnetic fields. [Pg.204]

Inclined belts provide additional areas of contact with the pulley magnetic field and can tolerate higher capacities than normal for a magnetic pulley apphcation. Table 3, which iadicates the correction factor to be appHed to the capacity, can be used with Table 2 to make the magnetic pulley diameter selection for an inclined belt. The initial cost of units can be related to the capacity or volume throughput. Costs mn about 35 for each m /h on the smaller units about 50 for each m /h on larger units. [Pg.420]

Typical magnetoconductance data for the individual MWCNT are shown in Fig. 4. At low temperature, reproducible aperiodic fluctuations appear in the magnetoconduclance. The positions of the peaks and the valleys with respect to magnetic field are temperature independent. In Fig. 5, we present the temperature dependence of the peak-to-peak amplitude of the conductance fluctuations for three selected peaks (see Fig. 4) as well as the rms amplitude of the fluctuations, rms[AG]. It may be seen that the fiuctuations have constant amplitudes at low temperature, which decrease slowly with increasing temperature following a weak power law at higher temperature. The turnover in the temperature dependence of the conductance fluctuations occurs at a critical temperature Tc = 0.3 K which, in contrast to the values discussed above, is independent of the magnetic field. This behaviour was found to be consistent with a quantum transport effect of universal character, the universal conductance fluctuations (UCF) [25,26]. UCFs were previously observed in mesoscopic weakly disordered... [Pg.117]


See other pages where Magnetic field selection is mentioned: [Pg.338]    [Pg.264]    [Pg.202]    [Pg.56]    [Pg.338]    [Pg.264]    [Pg.202]    [Pg.56]    [Pg.342]    [Pg.158]    [Pg.1133]    [Pg.1332]    [Pg.1355]    [Pg.1521]    [Pg.1522]    [Pg.1533]    [Pg.1547]    [Pg.1587]    [Pg.637]    [Pg.156]    [Pg.158]    [Pg.158]    [Pg.159]    [Pg.434]    [Pg.146]    [Pg.350]    [Pg.398]    [Pg.401]    [Pg.543]    [Pg.543]    [Pg.55]    [Pg.212]    [Pg.175]    [Pg.419]    [Pg.421]    [Pg.425]    [Pg.429]    [Pg.429]    [Pg.322]    [Pg.387]    [Pg.461]    [Pg.463]    [Pg.468]    [Pg.173]    [Pg.568]    [Pg.462]   
See also in sourсe #XX -- [ Pg.260 ]




SEARCH



Magnetic field effects spin selection rule

Selectivity Enhancement Using Magnetic Field Gradient Pulses

© 2024 chempedia.info