Only the most sensitive and expensive products are usually freeze-dried. Among these are antibiotics, antitoxins, antisera, certain vitamins, cancer chemotherapy drugs, diagnostic reagents, and other unstable and easily oxidiz-able materials. Because of the high value of the dryer load, they are often equipped with standby vacuum pumps and refrigeration units, as well as a standby electrical power supply and control instrumentation to protect against any failure. [Pg.692]

The gas turbine is widely used by electrical supply authorities for peak lopping and standby generation. Additionally, it is often employed for base-load operation when the fuel costs are low. [Pg.178]

Standby supply systems within an electrical installation provide supplies to critical loads on loss of normal power supplies. In an installation one or more of the following types of standby supply systems are likely to be found ... [Pg.224]

Based on the studies three pilot plants are proposed and analyzed for three oil platforms at Neft Dashlari. All plants are integrated system with three main components (1) a wind generator (8 m diameter wind turbines) to produce primary energy, (2) a standby diesel-electric set, to cover the lack of energy during calm periods, and (3) a storage battery bank to cover daily imbalances between power production and power load during the day. [Pg.263]

Standby loads—Loads that if they lose electricity will cause a hazardous condition or cause a substantial loss of product or research but which can sustain a power interruption of 60 sec. [Pg.1482]

ELECTRIC POWER SYSTEM Clas I,II and III Electnc System CSAB290 5 The Class III system pow ers designated safety -related and economic equipm i protection loads pump motors, valv es etc) Normally Class IV power supplies the Class III power W. cn the Class IV system fails two redundant standby diesel generators provide Class ni power The ac Class II and dc Class I systems supply un-mtermptible power to the control and safety svstems... [Pg.170]

Part 3 lists the initial factors that the designer should consider when planning an installation, to ensure its viability and safety. It is usually essential to contact the electricity supply company early and advise the total load and possible future increases so that an adequate supply will be available when required. Spaces for substations, standby facilities and switchrooms, and any cable duct requirements should be discussed with whoever is responsible for the site and buildings as soon as possible so that provision can be made in the plans. [Pg.133]


See other pages where Loads standby electrical is mentioned: [Pg.495]    [Pg.375]    [Pg.178]    [Pg.110]    [Pg.143]    [Pg.378]    [Pg.375]    [Pg.191]    [Pg.193]    [Pg.225]    [Pg.162]    [Pg.1483]    [Pg.273]    [Pg.316]    [Pg.177]    [Pg.60]    [Pg.127]    [Pg.1013]    [Pg.21]    [Pg.230]    [Pg.117]    [Pg.550]   