Isolation transformer

Fig. 10-5 Protection measure by separation of electrical operational equipment that is connected to the cathodically protected object via the housing, with an FI protection circuit leakage current circuit breaker (see Ref. 14) Tj and isolating transformers (see Ref. 15). Fig. 10-5 Protection measure by separation of electrical operational equipment that is connected to the cathodically protected object via the housing, with an FI protection circuit leakage current circuit breaker (see Ref. 14) Tj and isolating transformers (see Ref. 15).
Figure 3-61 The ground arrangements for the major converter topologies (a) the nonisolated dc/dc converter (b) the nonisolated, transformer-coupled converter (c) the isolated, transformer-coupled converter. Figure 3-61 The ground arrangements for the major converter topologies (a) the nonisolated dc/dc converter (b) the nonisolated, transformer-coupled converter (c) the isolated, transformer-coupled converter.
Care should be taken to avoid short circuits for instance, an insulated specimen, being common with the ground point of some potentiostats, can become electrically reconnected to the autoclave if the latter is not separated from ground by using an isolation transformer. [Pg.1120]

Power proportioning controllers are generally more sophisticated forms of the constant voltage units, employing solid state circuitry and rapid time-constant sensing circuits. An isolation transformer isolates the controller from line voltage fluctuations. If adequate insulation of the column from ambient air changes is provided, the controllers can be quite accurate. [Pg.324]

FIGURE 2.11 Common mode noise attenuation by shielded isolation transformer. [Pg.45]

Isolation transformers using a single shield provide attenuation in a range of 40 to 60 dB. Higher attenuation may be obtained by specially designed isolation... [Pg.45]

Common mode noise is converted to transverse mode noise in the impedance associated with the lines. Common mode noise when converted to transverse mode noise can be quite troublesome in sensitive, low-power devices. Filters or shielded isolation transformers reduce the amount by which common mode noise is converted to transverse mode noise. [Pg.160]

Contact detectors are somewhat easier to miniaturize. There are generally two subtypes those with twin axially mounted electrodes and those with twin or quadruple radially mounted electrodes. The former can be operated in DC mode or AC mode. In the DC mode, the detector signal directly originates from the field strength between the electrodes and, given the current, is inversely proportional to the detector cell resistance. In the AC mode, both axially and radially mounted electrodes form part of a closed primary circuit of an isolation transformer, the output of which is also inversely proportional to the cell conductivity. Alternatively, the output can be linearized with respect to the conductivity. [Pg.431]

Table 1 shows initial characterization of a small fraction of the isolated transformants. Strain 1 was the control , strains 2-6 were DNA insertional transformants that displayed relatively low Chi fluorescence, and strain 7 was a transformant with a relatively hi i Chi fluorescence. The Chi content of the cells and the Chi a/Chi b ratio were measured following strain cultivation in a small volume of liquid culture. A common feature of these transformants was the significantly lower than the control Chi content of the cells. Interestingly, this was the case for the five low-Chl fluorescence (strains 2-6) as well as the sole high Chi fluorescence strain ( 7). [Pg.116]

Measurements of the Chi a/Chl b ratio (Table 1) showed that strain 2 [Tanaka et al. 1998] was aberrant in Chi b biosynthesis (Chi Mess mutant). Strain 3 had a Chi a/Chi b ratio of 5.8/1 (Chl-deficient mutant), whereas strains 4-7 had either similar or lower than the control Chi [Pg.118]

Answer Usually, the control IC drives the switch directly. Therefore the IC must be located at the input side of the isolation transformer — that is called the primary side . The transformer windings that go to the output are therefore said to all lie on the secondary side. Between these primary and secondary sides lies no-man s land — the isolation boundary. Safety norms regulate how strong or effective this boundary must be. [Pg.195]

Readings may be taken directly on the millivoltmeter, but the apparatus lends itself readily to automatic recording by extension of leads from the voltmeter ampUfier circuit through an isolating transformer and a rectifier to a recorder (12). [Pg.100]

A SELV system is an extra-low voltage system (50 Vac or 120 Vdc free of ripple when measured between any two conductors), which is electrically separated from the earth (or ground) and other systems (such as the primary winding of an isolating transformer) in such a way that a single fault cannot give rise to the risk of electric shock. A PELV system is also an extra-low voltage system, but is one that is not electrically separated from earth. In all other respects it must satisfy the requirements of a SELV system. [Pg.364]

The isolation transformer TC was used in the PLC power supply circuit to prevent power interference. According to the electricity consumption of PLC, isolation transformer TC was configured with the standard, variable ratio of 1 1, the capacity of 100 VA transformer. The power instruct lights... [Pg.355]


See other pages where Isolation transformer is mentioned: [Pg.230]    [Pg.239]    [Pg.214]    [Pg.298]    [Pg.159]    [Pg.161]    [Pg.44]    [Pg.44]    [Pg.45]    [Pg.45]    [Pg.68]    [Pg.410]    [Pg.51]    [Pg.199]    [Pg.67]    [Pg.112]    [Pg.11]    [Pg.199]    [Pg.63]    [Pg.183]    [Pg.184]    [Pg.316]    [Pg.886]    [Pg.500]    [Pg.501]    [Pg.469]    [Pg.199]    [Pg.364]    [Pg.522]    [Pg.527]    [Pg.398]    [Pg.144]    [Pg.833]   
See also in sourсe #XX -- [ Pg.199 ]

See also in sourсe #XX -- [ Pg.199 ]

See also in sourсe #XX -- [ Pg.199 ]

See also in sourсe #XX -- [ Pg.82 , Pg.214 ]