Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Intermediate testing

Unknown intermediate / Test suspect materials to characterize unde-... [Pg.13]

The first project, gathering eight teams from six EC countries where more than 140 new extractants were prepared and studied, not counting all the precursors and intermediates. Tests carried out with these compounds on simulated and real waste showed the excellent chemical and radiolytic performance of calixarene derivatives. [Pg.202]

However, a plant does not always want to shut down when their SRVs need, for instance, intermediate testing because of a presumed failure. In that case, there are two options. The first solution is to install the valves on a changeover valve (Figure 10.16). In this system, one has a full redundancy of the SRV application, but this can become rather expensive. A calculation must be made weighing the initial investment against the eventual losses of a process shutdown. The investment might be justified if, otherwise, critical parts of the plant have to be shut down during each overhaul of the SRVs. [Pg.249]

The intermediate testing points will not only speed up the procedure but also help to identify the quantum efficiency of the reaction. This information will allow one to better select the appropriate preventive measures and provide better directions for use, if needed for instance in an operating room where vials are separated from their outer cardboard cartons. [Pg.116]

The EWF results were obtained for two HDPE grades at various test speeds. In addition to conventional EWF results, a special scaling analysis was performed to obtain CZM parameters. Some uncertainties due to the large scatter in measured separation distances were experienced, in particular at intermediate test speeds around 10 mm/s. However, the CZM data will only be used as the initial guess values in the numerical simulations of EWF tests. These simulations are designed for accurate calibration of the CZM parameters. Once the parameters are calibrated, they will be embedded in the predictive FSF model of the drop impact tests. [Pg.263]

Intermediate testing Studies conducted at 30°C/65% relative humidity (RH) and designed to moderately increase the rate of chemical degradation or physical changes for a drug substance or drug product intended to be stored long-term at 25°C. [Pg.424]

Model compound representing a class of relevant structures or intermediates. Tested reaction produces an intermediate for the pharmaceutical. [Pg.466]

Records of initial and subsequent lot/batch numbers. Intermediate test results with meaningful standards. [Pg.199]

Phosphorus-, tin-, boron- and indium-doped silicon samples give different photo-EMF signals as well as modified chemical reactivity in the direct synthesis. The actual concentrations of n- and p-dopands control the reactivity of the silylene intermediates. Tests on these silicon samples were demonstrated that the electronic state of the educt silicon significantly affects the selectivity. Thus the amounts of disilanes in the crude silane mixture decreased if the n-type semiconductor behavior of the educt silicon was intensified by doping. [Pg.513]

Based on the measurements made at the Inlet, exit, and Intermediate test points of the tubular reactor, the following data are available to determine the kinetic rate constants ... [Pg.426]

As expected, test temperatin-e will have a dramatic effect on the FCP kinetics of polymers owing considerably to their temperature-dependent viscoelastic nature. Indeed, studies of polystyrene and acrylonitrile-butadiene-styrene (ABS) have shown that FCP rates for given AX level generally decrease with decreasing test temperature (80). By contrast, a minimum FCP resistance was noted in polycarbonate and polysulfone at intermediate test temperatures (81,82). A complex test-temperatin-e response was also noted in studies on the influence... [Pg.3071]

The solids were mainly in a homogeneous transport state during the initial tests, except at the lowest gas velocity. During the second series of tests, the flow patterns changed from a homogeneous flow at the start of the experiments at low gas velocities to a more clustered or packet flow at the intermediate test velocities. The particles formed clusters for gas velocities in the range of 4.5-6.0 m/s for the particular set of conditions investigated. [Pg.638]

Figure 5. Indentation damage under intermediate test force. The area around the center of the contact circle is damaged. It is not an elastic contact, and it can make a scattering of the energy consumption. Figure 5. Indentation damage under intermediate test force. The area around the center of the contact circle is damaged. It is not an elastic contact, and it can make a scattering of the energy consumption.

See other pages where Intermediate testing is mentioned: [Pg.603]    [Pg.515]    [Pg.112]    [Pg.47]    [Pg.13]    [Pg.15]    [Pg.38]    [Pg.265]    [Pg.158]    [Pg.93]    [Pg.112]    [Pg.387]    [Pg.71]    [Pg.151]    [Pg.262]    [Pg.117]    [Pg.117]    [Pg.148]    [Pg.149]    [Pg.256]    [Pg.9]    [Pg.182]    [Pg.117]    [Pg.571]    [Pg.240]    [Pg.253]    [Pg.276]    [Pg.441]    [Pg.55]   
See also in sourсe #XX -- [ Pg.15 ]




SEARCH



Evidence and tests for the existence of intermediates

Intermediate precision test

© 2024 chempedia.info