Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Integral-Direct Methods

Gilmore, C.J. (1984) MITHRIL - an integrated direct-methods computer program... [Pg.354]

C. J. Gilmore, ]. Appl. Crystallogr., 17, 42 (1984). MITHRIL—An Integrated Direct-Methods Computer Program. [Pg.467]

Diffusion problems in one dimension lead to boundaiy value problems. The boundaiy conditions are applied at two different spatial locations at one side the concentration may be fixed and at the other side the flux may be fixed. Because the conditions are specified at two different locations, the problems are not initial value in character. It is not possible to begin at one position and integrate directly because at least one of the conditions is specified somewhere else and there are not enough conditions to begin the calculation. Thus, methods have been developed especially for boundary value problems. [Pg.475]

In the Direct SCF method, we do. not store the two-electron integrals over the basis functions, we recalculate them on demand every cycle of the HF procedure At first sight, this may seem wasteful, but Conventional methods rely on disk input/output transfer rates whilst Direct methods rely on processor power. There is obviously a balance between processor speed and disk I/O. Just for the record my calculation on aspirin (73 basis functions) took 363 s using the Direct method and 567 s using the Conventional method. [Pg.180]

The CPHF equations are linear and can be determined by standard matrix operations. The size of the U matrix is the number of occupied orbitals times the number of virtual orbitals, which in general is quite large, and the CPHF equations are normally solved by iterative methods. Furthermore, as illustrated above, the CPHF equations may be formulated either in an atomic orbital or molecular orbital basis. Although the latter has computational advantages in certain cases, the former is more suitable for use in connection with direct methods (where the atomic integrals are calculated as required), as discussed in Section 3.8.5. [Pg.246]

This equation cannot be integrated directly since the temperature 9 is expressed as a function of two independent variables, distance jc and time t. The method of solution involves transforming the equation so that the Laplace transform of 6 with respect to time is used in place of 9. The equation then involves only the Laplace transform 0 and the distance jc. The Laplace transform of 9 is defined by the relation ... [Pg.395]

The CC2 method [74] is an approximation to coupled cluster with singles and doubles (CCSD), and the excited state energies calculated have MP2 quality. An implementation that employs the resolution of identity (RI) approximation for two-electron integrals to reduce the CPU time is also available, RI-CC2 [75], which is suitable for large scale integral-direct calculations. This method has been implemented in TURBOMOLE [76],... [Pg.293]

Radioactivity measurement The radioactivities of lead isotopes and their decay products were measured with TRICARB 3380 liquid scintillation counter (Packard Inc.). The radioisotopes concerned, and their decay charateristies are shown in Figure 2. In the case of the direct method, the absolute radioactivity can be obtained by the integral... [Pg.195]

Pruszkowska et al. [135] described a simple and direct method for the determination of cadmium in coastal water utilizing a platform graphite furnace and Zeeman background correction. The furnace conditions are summarised in Table 5.1. These workers obtained a detection limit of 0.013 pg/1 in 12 pi samples, or about 0.16 pg cadmium in the coastal seawater sample. The characteristic integrated amount was 0.35 pg cadmium per 0.0044 A s. A matrix modifier containing di-ammonium hydrogen phosphate and nitric acid was used. Concentrations of cadmium in coastal seawater were calculated directly from a calibration curve. Standards contained sodium chloride and the same matrix modifier as the samples. No interference from the matrix was observed. [Pg.148]

The ratio of the fugacity/2 at the pressure P2 to the fugacity/i at the pressure Pj can be obtained by graphical or numerical integration, as indicated by the area between the two vertical lines under the isotherm for the real gas in Figure 10.6. However, as Pi approaches zero, the area becomes infinite. Hence, this direct method is not suitable for determining absolute values of the fugacity of a real gas. [Pg.240]

Since spline interpolation and integration is mucht faster than solving the sensitivity equations and the original differential equations, the direct method is superior to the indirect one in terms of numerical efficiency, whenever it is feasible. [Pg.289]

B.O. Roos and P.E.M. Siegbahn, The Direct Configuration Interaction Method from Molecular Integrals, in Methods of Electronic Structure Theory (H.F. Schaefer III, ed.), Plenum Press, New York (1977). [Pg.292]

Sample Preparation/Extraction The process of separating potentially interfering components from a sample prior to LC-MS analysis for the purposes of improving sensitivity, specificity, and/or method ruggedness. Variations include solid phase extraction (SPE), liquid-liquid extraction (LLE), and protein precipitation (PPT). Extraction may be performed off-line, in which the cleanup is completely independent from the LC-MS analysis, or on-line, in which the cleanup is integrated directly into the LC-MS analysis. [Pg.21]

In the CNDO and INDO methods Pople et al. set the resonance integral directly proportional to the overlap integral Sy between the orbitals yi and fj centered on atoms A and B... [Pg.32]


See other pages where Integral-Direct Methods is mentioned: [Pg.230]    [Pg.231]    [Pg.5166]    [Pg.3227]    [Pg.463]    [Pg.63]    [Pg.78]    [Pg.79]    [Pg.142]    [Pg.143]    [Pg.442]    [Pg.445]    [Pg.598]    [Pg.488]    [Pg.674]    [Pg.52]    [Pg.402]    [Pg.213]    [Pg.338]    [Pg.109]    [Pg.120]    [Pg.76]    [Pg.340]    [Pg.58]    [Pg.292]    [Pg.353]    [Pg.305]    [Pg.173]    [Pg.440]    [Pg.279]    [Pg.262]    [Pg.87]    [Pg.25]   
See also in sourсe #XX -- [ Pg.230 ]




SEARCH



Direct integration methods

Direct integration methods

Direct method

Direct-computation integral methods

Direction Methods

Integrals direct

Integration method

Numerical or direct integration and other approximate methods

Surface integral equation direct method

© 2024 chempedia.info