Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Inference chain

In the next group of chapters we shall discuss condensation or step-growth polymers and polymerizations in Chap. 5, addition or chain-growth polymers and polymerizations in Chap. 6, and copolymers and stereoregular polymers in Chap. 7. It should not be inferred from this that these are the only classes of polymers and polymerization reactions. Topics such as ring-opening polymeri-... [Pg.264]

This conceptual link extends to surfaces that are not so obviously similar in stmcture to molecular species. For example, the early Ziegler catalysts for polymerization of propylene were a-TiCl. Today, supported Ti complexes are used instead (26,57). These catalysts are selective for stereospecific polymerization, giving high yields of isotactic polypropylene from propylene. The catalytic sites are beheved to be located at the edges of TiCl crystals. The surface stmctures have been inferred to incorporate anion vacancies that is, sites where CL ions are not present and where TL" ions are exposed (66). These cations exist in octahedral surroundings, The polymerization has been explained by a mechanism whereby the growing polymer chain and an adsorbed propylene bonded cis to it on the surface undergo an insertion reaction (67). In this respect, there is no essential difference between the explanation of the surface catalyzed polymerization and that catalyzed in solution. [Pg.175]

Asp 189 at the bottom of the substrate specificity pocket interacts with Lys and Arg side chains of the substrate, and this is the basis for the preferred cleavage sites of trypsin (see Figures 11.11 and 11.12). It is almost trivial to infer, from these observations, that a replacement of Asp 189 with Lys would produce a mutant that would prefer to cleave substrates adjacent to negatively charged residues, especially Asp. On a computer display, similar Asp-Lys interactions between enzyme and substrate can be modeled within the substrate specificity pocket but reversed compared with the wild-type enzyme. [Pg.215]

The hindering potentials must be of importance in the question of the flexibility of long-chain molecules such as synthetic polymers and naturally occurring macromolecules such as proteins and nucleic acids. Again, direct information on barriers in these molecules will be difficult to obtain but inferences can presumably be drawn from experiments on simpler analogues. [Pg.368]

Applying the TABS model to the stress distribution function f(x), the probability of bond scission was calculated as a function of position along the chain, giving a Gaussian-like distribution function with a standard deviation a 6% for a perfectly extended chain. From the parabolic distribution of stress (Eq. 83), it was inferred that fH < fB near the chain extremities, and therefore, the polymer should remain coiled at its ends. When this fact is included into the calculations of f( [/) (Eq. 70), it was found that a is an increasing function of temperature whereas e( increases with chain flexibility [100],... [Pg.130]

From the NMR data of the polymers and low-molecular models, it was inferred that the central C—H carbons in the aliphatic chain in polymer A undergo motions which do not involve the OCH2 carbons to a great extent. At ambiet temperatures, the chemical shift anisotropy of the 0(CH2)4 carbons of polymer A are partially averaged by molecular motion and move between lattice positions at a rate which is fast compared to the methylene chemical shift interaction. [Pg.11]

The number of the constraints to chain mobility shown in Fig. 16 decreases with increasing temperature, reflecting the increase of the free volume. From a comparison of the spectra in Fig. 15 with line shapes calculated for flexible chains on a diamond lattice 23 (one can infer that the average length of the flexible unit increases from 3-5 bonds at room temperyture to about 10-15 bonds at 380 K. Our model thus can quantitatively explain the gradual increase of the number of conformations accessible to the chain motion. The earlier XH wide line data 72 are also in accord with our findings. [Pg.41]

A similar approach has been suggested in other studies of plant cells [57] and protein precipitates [133]. However, information on the rate of the size distribution shift process cannot be inferred from chain-length measurements made only at the beginning and end of the experiment. To date, there have been no reports on the progressive modification of the size distribution of plant cells subjected to continued exposure to turbulent forces. There are, however, a number of studies which address the break-up of mycelial hyphae in agitated vessels... [Pg.157]

In discussing these pathways and considering the broad spectrum of analytical chemistry applications in contrast to the limited supply of CRMs, one has to keep in mind that the unbroken chain of comparisons may be hterally demonstrated in only a few instances and that for a long time to come data are accepted by inferred quality, including traceability. [Pg.251]

In their broadest application, CRMs are used as controls to verify in a direct comparison the accuracy of the results of a particular measurement parallel with this verification, traceability may be demonstrated. Under conditions demonstrated to be equal for sample and CRM, agreement of results, e.g. as defined above, is proof. Since such possibilities for a direct comparison between samples and a CRM are rare, the user s claims for accuracy and traceability have to be made by inference. Naturally, the use of several CRMs of similar matrix but different analyte content will strengthen the user s inference. Even so, the user stiU has to assess and account for all uncertainties in this comparison of results. These imcertainty calculations must include beyond the common analytical uncertainty budget (i) a component that reflects material matrix effects, (2) a component that reflects differences in the amount of substance determined, (3) the uncertainty of the certified or reference value(s) used, and 4) the uncertainty of the comparison itself AU this information certainly supports the assertion of accuracy in relation to the CRM. However, the requirement of the imbroken chain of comparisons wiU not be formally fulfilled. [Pg.252]


See other pages where Inference chain is mentioned: [Pg.172]    [Pg.218]    [Pg.218]    [Pg.172]    [Pg.218]    [Pg.218]    [Pg.479]    [Pg.407]    [Pg.28]    [Pg.175]    [Pg.533]    [Pg.533]    [Pg.533]    [Pg.533]    [Pg.534]    [Pg.321]    [Pg.170]    [Pg.176]    [Pg.472]    [Pg.147]    [Pg.430]    [Pg.449]    [Pg.449]    [Pg.12]    [Pg.178]    [Pg.199]    [Pg.43]    [Pg.163]    [Pg.869]    [Pg.126]    [Pg.127]    [Pg.682]    [Pg.320]    [Pg.362]    [Pg.83]    [Pg.564]    [Pg.636]    [Pg.158]    [Pg.319]    [Pg.5]    [Pg.78]    [Pg.410]   
See also in sourсe #XX -- [ Pg.270 ]




SEARCH



Inference

© 2024 chempedia.info