Figure 6.28 shows the I-V characteristics of a single epitaxial emitter cell. A maximum current gain of about 15 is obtained. This current gain is extremely sensitive to the base contact implant spacing from the edge of the emitter mesa (in the... [Pg.196]

From the previous discussion, it is gathered that there are two potential issues that need to be addressed in any future research on SiC BJTs (1) The current gain of the devices is low (10-15) at present and (2) the base resistance is rather high due to the high sheet resistance of the base layer and the necessity of keeping the base contact implant at least 5 micron away from the edge of the emitter mesa. The current gain... [Pg.199]

Besides external contact lenses, there are surgically implanted intraocular contact lenses that are usually used to replace the eye s natural lens after cataract surgery these lenses are normally based on silicone or PMMA and lie outside the scope of this entry. [Pg.1351]

PVDE is a nontoxic resin and may be safely used in articles intended for repeated contact with food (190). Based on studies under controked conditions, including acute oral, systemic, subchronic, and subacute contact implantation and tissue culture tests, no adverse toxicological or biological response has been found in test animals (191,192). PVDE is acceptable for use in processing and storage areas in contact with meat or poultry products prepared under federal inspection and it complies with the 3-A sanitary standards for dairy equipment. [Pg.388]

Siloxane-containing devices have also been used as contact lenses, tracheostomy vents, tracheal stents, antireflux cuffs, extracorporeal dialysis, ureteral stents, tibial cups, synovial fluids, toe joints, testes penile prosthesis, gluteal pads, hip implants, pacemakers, intra-aortic balloon pumps, heart valves, eustachian tubes, wrist joints, ear frames, finger joints, and in the construction of brain membranes. Almost all the siloxane polymers are based on various polydimethylsiloxanes. [Pg.597]

Another p-n junction-based hydrogen sensor has been produced by implanting palladium ions into 6H n-type SiC material [67]. Gold-plated copper contacted the p-n junction device. The gas response was measured as (small) changes in current as the gas ambient was varied between air and 4% in argon in the temperature range 23-240°C. For an absolute voltage above 1.2V, the p-n junction broke down. [Pg.44]

Figure 6.12 Cross-sectional view of the 4H-SiC power BJT fabrication, (a) Starting epilayer structure. (b) Dry etching of emitter and base epilayers. (c) p implantation for guard rings and contacts to p-base. (d) Formation of ohmic contacts, (e) Over layer metal deposition, (f) Double metal process. Figure 6.12 Cross-sectional view of the 4H-SiC power BJT fabrication, (a) Starting epilayer structure. (b) Dry etching of emitter and base epilayers. (c) p implantation for guard rings and contacts to p-base. (d) Formation of ohmic contacts, (e) Over layer metal deposition, (f) Double metal process.
Polyelectrolytes have been widely investigated as components of biocompatible materials. Biomaterials come into contact with blood when used as components in invasive instruments, implant devices, extracorporeal devices in contact with blood flow, implanted parts of hard structural elements, implanted parts of organs, implanted soft tissue substitutes and drug delivery devices. Approaches to the development of blood compatible materials include surface modification to give blood compatibility, polyelectrolyte-based systems which adsorb and/or release heparin as well as polyelectrolytes which mimic the biological activity of heparin. [Pg.39]

In general, a medical device is defined as follows a medical device is an implant and equipment to be used either to achieve disease diagnosis, medical treatment, or disease prevention for human and animals, or to influence the physical structure and function of human and animals. Medical devices for humans may also be classified based on whether and how long the device is in contact with tissue or cells and on the degree of disjunction induced by the device when in a disabling situation. The term covers various categories, such as scissors and tweezers, with small risk to human function, to central venous catheters, artificial dialysis (human kidney), and pacemakers, with high risk to human function. [Pg.230]

In a second embodiment the strip detectors A to H are mounted on an intrinsic p-type silicon substrate 3A covered by a silicon oxide layer 3B. A patterned arrangement of conductor tracks 21 is formed in the semiconductor base 3B. Each track is formed by diffusion or ion-implantation of an n-type dopant material, and isolated from adjacent tracks by means of a channel stop network 23. Bridging links of nichrome-gold are formed to define and connect the read-out regions to the tracks 21. The links 25 are paired and thus provide voltage detection contacts. The tracks 21 are connected to connection pads 29. Signal processing circuitry is incorporated in the semiconductor base layer 3B. [Pg.32]

An erodible implant system based on PVA has also been investigated. The bioavailability of pilocarpine was shown to be increased sixteen-fold using this system. The system showed considerable promise for prolonged drug delivery since vision is minimally affected by the presence of an insert positioned on the sclera. When the device is placed in the lower fornix, the contact area for the released drug is the sclera and little material is in contact with the cornea. [Pg.313]


See other pages where Implants base contact is mentioned: [Pg.179]    [Pg.188]    [Pg.196]    [Pg.200]    [Pg.57]    [Pg.460]    [Pg.215]    [Pg.334]    [Pg.115]    [Pg.436]    [Pg.380]    [Pg.121]    [Pg.133]    [Pg.40]    [Pg.153]    [Pg.267]    [Pg.372]    [Pg.131]    [Pg.35]    [Pg.304]    [Pg.281]    [Pg.68]    [Pg.116]    [Pg.156]    [Pg.179]    [Pg.186]    [Pg.195]    [Pg.341]    [Pg.100]    [Pg.116]    [Pg.5]    [Pg.270]    [Pg.294]    [Pg.231]    [Pg.118]    [Pg.366]    [Pg.189]    [Pg.329]    [Pg.1279]   