However, the ideal control algorithm would have no overshoot, no offset, and a quick response characteristic. For this purpose, a proportional action (P), an integral action (I), and a differential action (D) were combined as a PID controller as follows. [Pg.227]

In many process control applications, the control algorithm consists of three modes proportional (P), integral (I), and derivative (D). The ideal PID controller equation is... [Pg.204]

As early as 1974, Thoma introduced the concept of time dependent junctions [24] in order to switch off and on connections between power ports. Mosterman picked up this idea and introduced controlled Junctions [21], In contrast to switched power junctions, a local control algorithm associated with a controlled junction switches off all adjacent bonds of a controlled junction when a switching device considered as an ideal switch turns off and re-activates all bonds when the switch is closed. That is, an ideal switch in ON-mode is represented by a standard 0- or 1-junction. In OFF-mode the junction is replaced by a source of value zero as shown in Fig. 2.10. [Pg.30]

The feedback information in a supply chain results in the reduction or increase of the source operation rate. It in turn helps in proper supply line scheduling. Based on the congestion status, different congestion control algorithms are used. Each one of them may be thought of as an estimator. A DANN works as an ideal estimator to replace all of them. [Pg.255]

The clipped optimal control algorithm is proposed by Dyke et al, (1996). It is currently the most widely used algorithm for MR damper control. This strategy consists of a bang-bang (on-off) t3 e of controller that causes the damper to generate adesirable control force which is determined by an ideal active controller (in state feedback form). A force feedback loop is used to produce... [Pg.317]

Because the digital computer calculates a new value of output for a given loop only once each cycle, it cannot solve differential equations. Instead, digital control algorithms are difference equations, whose time base is the sampling interval. The differential equation for an ideal noninteracting analog controller is... [Pg.119]

Torque may also be maintained in a controlled strain rheometer such as shown in Figure 8.2.2 by using feedback from the torque sensor to adjust the motor velocity or position. However, control is typically difficult because of the sample response. Ideally one should include the viscosity of the sample in the control algorithm. Performance can be improved significantly by avoiding the sample and closing the feedback loop around a torque sensor on the motor, such as motor current to a dc motor (Michel, 1988). However, brush fiiction in the motor limits the lowest torque levels to 10 to 10- N-m. [Pg.349]

The worst case response time of PWMo// tasks is 316.184 ms for PWMo//-3, which has the lowest priority among them. That is only 16.184 ms apart from the ideal and supposes an error of 8% for the shorter duty cycle of 200 ms. This actuation error could be fed back to the Simulink model in order to adjust accordingly the control algorithm. [Pg.96]

Unfortunately, the ideal proportional-derivative control algorithm in Eq. 8-11 is physically unrealizable because it cannot be implemented exactly using either analog or digital controllers. For analog controllers, the transfer function in (8-11) can be approximated by... [Pg.139]

Ideally, the physician s full DEA number should not be preprinted on the prescription pad most prescriptions will not be for controlled substances and will not require the registration number, and anyone in possession of a valid DEA number may find it easier to commit prescription fraud. Some physicians may intentionally omit part or aU of their DEA number on a prescription and instead write pharmacist call to verify or call for registration number. This practice works only when the pharmacist may independently verify the authenticity of the prescription, and patients must be advised to fill the prescription during the prescriber s office hours. Pharmacists can ascertain the Kkely authenticity of a physician s DEA number using an algorithm. [Pg.1147]


See other pages where Ideal control algorithm is mentioned: [Pg.214]    [Pg.206]    [Pg.255]    [Pg.51]    [Pg.202]    [Pg.370]    [Pg.14]    [Pg.336]    [Pg.101]    [Pg.1925]    [Pg.1]    [Pg.835]    [Pg.168]    [Pg.146]    [Pg.383]    [Pg.183]    [Pg.38]    [Pg.367]    [Pg.309]    [Pg.177]    [Pg.289]    [Pg.445]    [Pg.39]    [Pg.42]    [Pg.869]    [Pg.310]    [Pg.329]    [Pg.761]    [Pg.9]    [Pg.254]    [Pg.1355]    [Pg.4]    [Pg.1090]    [Pg.211]    [Pg.618]    [Pg.516]    [Pg.22]    [Pg.259]    [Pg.1]   