Hybrid mass analyzers

Strupat K, Kovtoun V, Bui H, Viner R, Stafford G, Homing S. MALDI produced ions inspected with a linear ion trap-Orbitrap hybrid mass analyzer. J Am Soc Mass Spectrom 2009 20 1451-1463. [Pg.481]

There are four main MS/MS modes (including product ion analysis, NLS, PIS, and SRM) that are particularly useful in lipidomics (Figure 2.7). The general principles of these MS/MS techniques can be easily explained by using a QqQ-type mass spectrometer, as briefly described below. Although different parameters are used for mass spectrometers with different hybrid mass analyzers, the underlying chemical principles are quite similar. Comparisons among these techniques are summarized in Table 2.2. [Pg.37]

Thevis, M., Makarov, A.A., Homing, S., and Schanzer, W. (2005) Mass spectrometry of stanozolol and its analogues using electrospray ionization and collision-induced dissociation with quadrupole-linear ion trap and linear ion trap-orbitrap hybrid mass analyzers. Rapid Communications in Mass Spectrometry, 19,3369-3378. [Pg.218]

A TOF analyzer can be used alone or in conjunction with other analyzers to function as a hybrid mass spectrometer. The hybrids provide advantages not attainable, or difficult to attain by the... [Pg.154]

The term Q/TOF is used to describe a type of hybrid mass spectrometer system in which a quadrupole analyzer (Q) is used in conjunction with a time-of-flight analyzer (TOP). The use of two analyzers together (hybridized) provides distinct advantages that cannot be achieved by either analyzer individually. In the Q/TOF, the quadrupole is used in one of two modes to select the ions to be examined, and the TOF analyzer measures the actual mass spectrum. Hexapole assemblies are also used to help collimate the ion beams. The hybrid orthogonal Q/TOF instrument is illustrated in Figure 23.1. [Pg.169]

Commercial mass analyzers are based almost entirely on quadrupoles, magnetic sectors (with or without an added electric sector for high-resolution work), and time-of-flight (TOE) configurations or a combination of these. There are also ion traps and ion cyclotron resonance instruments. These are discussed as single use and combined (hybrid) use. [Pg.280]

Mass analyzers interrogate and resolve ions produced by an ion source based on their m/z ratios. Several types of mass analyzers are utilized for proteomic analysis including time-of-flight (TOF) quadrupoles, ion traps, and Fourier transform ion cyclotron resonance (FTICR). Mass analyzers may be assembled in hybrid configurations. MS instruments such as quadrupole TOF and quadra-pole ion trap-FTICR facilitate diversified applications and achieved great success. [Pg.381]

Due to their fast acquisition rate and high resolution capabilities TOP mass analyzers are often used as the last mass analyzing stage in hybrid tandem mass... [Pg.34]

The TOF mass analyzer has a low duty cycle, and the combination with an ion accumulation device such as an ion trap is therefore very advantageous. It offers also MS capabilities with accurate mass measurement. In all acquisition modes, the ions are accelerated into the time of flight for mass analysis. Various other hybrid mass spectrometers with TOF have been described, including quadrupole ion trap [70] and linear ion trap [58]. High energy tandem mass spectrometry can be performed on TOF-TOF mass spectrometers [71, 72]. [Pg.36]

Orbitrap The newest of the major mass analyzers, the Orbitrap is a hybrid MS consisting of a LIT mass analyzer, or transmission quadmpoles connected to the high-resolution Orbitrap mass analyzer. The Orbitrap utilizes electrical fields between sections of a roughly egg-shaped outer electrode and an inner (spindle) electrode (Chapter 5). Ions orbit between the inner and outer electrodes and their oscillation is recorded on detector plates (Hardman and Makarov, 2003 Hu et al., 2005). As with the FTICR, fast Fourier transform of the raw data is used to convert the data for mass analysis, making the Orbitrap the second major type of FTMS instrument. The resolving power of the Orbitrap is intermediate... [Pg.18]

Hybrid Mass Spectrometer A tandem mass spectrometer comprised of multiple mass analyzers of different types. A Q-TOF is a hybrid, but a triple quadmpole is not. Ideally, a hybrid instrument harnesses the best features of each mass analyzer type to produce a system perhaps greater than the sum of the parts. [Pg.19]


See other pages where Hybrid mass analyzers is mentioned: [Pg.1029]    [Pg.174]    [Pg.322]    [Pg.1029]    [Pg.140]    [Pg.756]    [Pg.785]    [Pg.88]    [Pg.691]    [Pg.435]    [Pg.197]    [Pg.328]    [Pg.1029]    [Pg.174]    [Pg.322]    [Pg.1029]    [Pg.140]    [Pg.756]    [Pg.785]    [Pg.88]    [Pg.691]    [Pg.435]    [Pg.197]    [Pg.328]    [Pg.163]    [Pg.243]    [Pg.282]    [Pg.14]    [Pg.144]    [Pg.153]    [Pg.65]    [Pg.95]    [Pg.97]    [Pg.52]    [Pg.231]    [Pg.173]    [Pg.173]    [Pg.147]    [Pg.41]    [Pg.48]    [Pg.226]    [Pg.342]    [Pg.21]    [Pg.68]    [Pg.95]    [Pg.966]    [Pg.18]    [Pg.18]   