Tube banks heat exchanger

Countcrflmv exchanger, float Eng head, carbon above heat exchanger tube bank... [Pg.917]

Problem. In this example, we consider the flow around a body. Air, at atmospheric pressure, flows at 20 m s 1 across a bank of heat exchanger tubes. A l/10th-scale model is built. At what velocity must air flow over the model bank of tubes to achieve dynamic similarity ... [Pg.184]

Although the improvement of gas solid contact is usually the main objective when various baffles are selected, some concomitant improvement, when a bank of heat exchanger tubes must be used, is also welcome. The fluidized beds with tubes immersed in the bed have a number of important applications in industry. [Pg.189]

Chenoweth, J. W. and J. Taborek, Flow-Induced Tube Vibration Data Banks for Shell-and-Tube Heat Exchangers, Heat Transfer Eng,Y. 2, Oct.-Dec. (1980) p. 28. [Pg.286]

It is shown in Section 9.9.5 that, with the existence of various bypass and leakage streams in practical heat exchangers, the flow patterns of the shell-side fluid, as shown in Figure 9.79, are complex in the extreme and far removed from the idealised cross-flow situation discussed in Section 9.4.4. One simple way of using the equations for cross-flow presented in Section 9.4.4, however, is to multiply the shell-side coefficient obtained from these equations by the factor 0.6 in order to obtain at least an estimate of the shell-side coefficient in a practical situation. The pioneering work of Kern(28) and DoNOHUE(lll who used correlations based on the total stream flow and empirical methods to allow for the performance of real exchangers compared with that for cross-flow over ideal tube banks, went much further and. [Pg.527]

The complex flow pattern on the shell-side, and the great number of variables involved, make it difficult to predict the shell-side coefficient and pressure drop with complete assurance. In methods used for the design of exchangers prior to about 1960 no attempt was made to account for the leakage and bypass streams. Correlations were based on the total stream flow, and empirical methods were used to account for the performance of real exchangers compared with that for cross flow over ideal tube banks. Typical of these bulk-flow methods are those of Kern (1950) and Donohue (1955). Reliable predictions can only be achieved by comprehensive analysis of the contribution to heat transfer and pressure drop made by the individual streams shown in Figure 12.26. Tinker (1951, 1958) published the first detailed stream-analysis method for predicting shell-side heat-transfer coefficients and pressure drop, and the methods subsequently developed... [Pg.670]

For other geometries, such as banks of tubes, the correlations developed for heat exchangers may be employed. These are discussed at length in various places [23, 26, 27, 33],... [Pg.31]

Figure 8.4. Example of tubular heat exchangers (see also Fig. 8.14). (a) Double-pipe exchanger, (b) Scraped inner surface of a double-pipe exchanger, (c) Shell-and-tube exchanger with fixed tube sheets, (d) Kettle-type reboiler, (e) Horizontal shell side thermosiphon reboiler, (f) Vertical tube side thermosiphon reboiler, (g) Internal reboiler in a tower, (h) Air cooler with induced draft fan above the tube bank, (i) Air cooler with forced draft fan below the tube bank. Figure 8.4. Example of tubular heat exchangers (see also Fig. 8.14). (a) Double-pipe exchanger, (b) Scraped inner surface of a double-pipe exchanger, (c) Shell-and-tube exchanger with fixed tube sheets, (d) Kettle-type reboiler, (e) Horizontal shell side thermosiphon reboiler, (f) Vertical tube side thermosiphon reboiler, (g) Internal reboiler in a tower, (h) Air cooler with induced draft fan above the tube bank, (i) Air cooler with forced draft fan below the tube bank.
Other Auxiliaries. The inlet feed coolers are conventional marine shell and tube heat exchangers, three in each bank. One bank is counterflow to the brine and the other is counterflow to the product water. Final temperature approach is in the order of 10° F. [Pg.105]

Saturated steam at 100 lb/in2 abs is to be used to heat carbon dioxide in a cross-flow heat exchanger consisting of four hundred 1-in-OD brass tubes in a square in-line array. The distance between tube centers is j in, in both the normal- and parallel-flow directions. The carbon dioxide flows across the tube bank, while the steam is condensed on the inside of the tubes. A flow rate of I lb ,/s of CO at 15 lb/in2 abs and 70°F is to be heated to 200°F. Estimate the length of the tubes to accomplish this heating. Assume that the steam-side heat-transfer coefficient is 1000 Btu/h ft2 °F, and neglect the thermal resistance of the tube wall. [Pg.575]

Forced convection heat transfer is probably the most common mode in the process industries. Forced flows may be internal or external. This subsection briefly introduces correlations for estimating heat-transfer coefficients for flows in tubes and ducts flows across plates, cylinders, and spheres flows through tube banks and packed beds heat transfer to nonevaporating falling films and rotating surfaces. Section 11 introduces several types of heat exchangers, design procedures, overall heat-transfer coefficients, and mean temperature differences. [Pg.9]

Heat-transfer coefficient for cross flow over an ideal tube bank Fouling coefficient on outside of tube Heat-transfer coefficient in a plate heat exchanger Shell-side heat-transfer coefficient Heat transfer coefficient to vessel wall or coil Heat transfer factor defined by equation 12.14 Heat-transfer factor defined by equation 12.15 Friction factor... [Pg.784]

S l 12 Design a heat exchanger to pasteurize mill by steam in a dairy plant. Milk is lo flow through a bank of 1.2-cni internal diameter lubes while. steam condenses outside the tubes at I aim. Milk is to enter the tubes at 4 C, and it is to be heated to 72°C at a rate of 15 L/s, Making reasonable assumptions, you are lo specify the tube length and the number of tubes, and the pump for the heat exchanger. [Pg.519]


See other pages where Tube banks heat exchanger is mentioned: [Pg.915]    [Pg.915]    [Pg.5]    [Pg.164]    [Pg.573]    [Pg.7]    [Pg.582]    [Pg.662]    [Pg.1037]    [Pg.1076]    [Pg.1077]    [Pg.1433]    [Pg.141]    [Pg.25]    [Pg.216]    [Pg.523]    [Pg.199]    [Pg.213]    [Pg.117]    [Pg.36]    [Pg.25]    [Pg.299]    [Pg.28]    [Pg.408]    [Pg.487]    [Pg.860]    [Pg.899]    [Pg.900]    [Pg.1256]    [Pg.670]    [Pg.436]    [Pg.278]    [Pg.342]   