The U.S.Department for Housing and Urban Development s rule 3280.308 established formaldehyde emission standards for particleboard and hardwood plywood paneling used in mobile homes. These standards took effect February 11, 1985. The certification program under this rule requires each manufacturer to develop a quality control in-plant testing program that relates to tests conducted in a large scale environmental chamber. [Pg.154]

Upon completion of the chamber test, the hardwood plywood paneling or particleboard is removed and 12 each 7.00cm x 12.7 cm specimens are randomly cut from each board loaded into the chamber. For the surface monitor (FSEM) and the small scale test chamber(SSTC), one 30.5cm X 30.5cm board is cut from each board loaded in the chamber. These samples are immediately tested by the Equilibrium Jar for particleboard or the Two Hour Desiccator or FSEM or SSTC for all wood product types. The values obtained from each test are averaged and are then compared to the chamber concentration observed for that loading and air change rate. [Pg.178]

Figure 14 provides a graphical representation of 27 chamber tests conducted on a variety of veneer, print, a paper overlay finished hardwood plywood paneling. Even though it is not shown, a breakdown by different product type did not affect the correlation by anymore than 5%. As with particleboard, the cloud of points below 0.2 ppm represents current production made to meet the H.U.D. hardwood plywood paneling standard (0.2 ppm chamber). The group of points between 0.24 and 0.36 ppm chamber are from earlier chamber studies needed to define the curve. [Pg.179]

Hour Desiccator for G-P hardwood plywood paneling correlates to the large scale test chamber. [Pg.185]

In-plant quality control and routine acceptance testing by property verification organizations such as the Hardwood Plywood Manufacturers Association and the National Particleboard Association require a method more efficient than the chamber for routinely monitoring trends in emission characteristics of products. The relationship between chamber and the small scale desiccator test observations is illustrated by a series of 76 tests accomplished during the past year on hardwood plywood wall panel products at a chamber loading rate of 0.29 sq ft per cu ft ... [Pg.22]