W = wt of dry sample in grams Method No 210. Priming Composition (Lead Starter Type), used as a priming compn for the M127 (T73) Parachute White Star Ground Signal. US Military Specification MIL-S-13257F (1967) requirements Moisture, max 0.10%, and Composition Pb peroxide (of... [Pg.1065]

Method No 303. Delay Composition for the M127 (T73) Ground Signal - K nitrate 60.84,... [Pg.1075]

Navy Ground Signal Flares were cylindrical cardboard containers 3% inches long 1 % inches in diam, filled with red, white or green compns. Used to signal aircraft from the ground (p 242, Fig 396 of Ref 1) ... [Pg.473]

For more information about TiCl4 see in Vol 8, P507-L to P508-R, under. . 2) Colored and White Smoke..in the entry on Pyrotechnics Refs 1) Gmelin, Syst Nr 41 (1951), 310 ff la) G.F. Schladt, Development of Composition for White Smoke Puff Ground Signals , PATR 134 (1931) 2. H. EUern, Modem... [Pg.724]

J.H. Robinson, Development of Alternative Parachute for Ground Signals , PATR 1299... [Pg.143]

E. Crane, B. Werbel, and G. Weingarten, Picatinny Arsenal, Dover, N. J., Improved Green, Red, Yellow and Violet Smoke Compositions for Rocket-Type Parachute Ground Signals, TM 1033 (1963). [Pg.440]

A physically separate and remote reference electrode is desirable becau.se the reference electrode is not electrically isolated from the inputs to the differential amplifier. The reference electrode is in contact with the person and consequently is electrically coupled to both inputs of the amplifier by the electrical impedance of the body. This impedance is a function of distance, i.e., the further away the reference electrode is, the greater is the attenuation. The reference electrode forms a floating ground signal rather than a true ground. Furthermore, the noise signal that can be introduced by the reference electrode is not necessarily a conunon-mode signal that will be removed by the differential amplification process. [Pg.867]

Measuring Grounded Signal Sources, Avoiding Loops... [Pg.1962]

The preferable input mode for a grounded signal is differential or NRSE mode. With either of these configurations, any potential difference between references of the source and the measuring device appears as common-mode voltage to the measurement system and is subtracted from the measured signal. [Pg.1963]

CSEE-Transport developed its own technology in response to the needs of TVM 430 ground signaling equipment, used since 1993 for cabin signaling and speed control for the Paris-Lille high-speed railway line (LGV Ligne a Grande Vitesse) [GUI 92]. This equipment has been in commercial use since 1993 in the Chaimel Tunnel. [Pg.70]


See other pages where Signal ground is mentioned: [Pg.1036]    [Pg.295]    [Pg.486]    [Pg.448]    [Pg.788]    [Pg.348]    [Pg.469]    [Pg.476]    [Pg.448]    [Pg.788]    [Pg.243]    [Pg.295]    [Pg.486]    [Pg.447]    [Pg.448]    [Pg.788]    [Pg.127]    [Pg.42]    [Pg.242]    [Pg.104]    [Pg.127]    [Pg.127]    [Pg.1013]    [Pg.1237]    [Pg.1238]    [Pg.1241]    [Pg.1242]    [Pg.1700]    [Pg.1962]    [Pg.87]    [Pg.307]    [Pg.177]    [Pg.322]    [Pg.387]    [Pg.27]   