Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Geometry derivative equation parameters

Having derived the parameter Et by experiment, and knowing the detailed geometry, it is possible by equating A and V to set up the hnear equations which connect Et with the parameters e a, e or I, of the additivity model 6). Here it should be noted that the parameters of the additivity model depend on the kind of hgand and, when different hgands are present, must be given an extra index. [Pg.93]

In the Lagrangian frame, droplet trajectories in the spray may be calculated using Thomas 2-D equations of motion for a sphere 5791 or the simplified forms)154 1561 The gas velocity distribution in the spray can be determined by either numerical modeling or direct experimental measurements. Using the uncoupled solution approach, many CFD software packages or Navier-Stokes solvers can be used to calculate the gas velocity distribution for various process parameters and atomizer geometries/configurations. On the other hand, somesimple expressions for the gas velocity distribution can be derived from... [Pg.369]

Errors and confusion in modelling arise because the complex set of coupled, nonlinear, partial differential equations are not usually an exact representation of the physical system. As examples, first consider the input parameters, such as chemical rate constants or diffusion coefficients. These input quantities, used as submodels in the detailed model, must be derived from more fundamental theories, models or experiments. They are usually not known to any appreciable accuracy and often their values are simply guesses. Or consider the geometry used in a calculation. It is often one or two dimensions less than needed to completely describe the real system. Multidimensional effects which may be important are either crudely approximated or ignored. This lack of exact correspondence between the model adopted and the actual physical system constitutes the basic problem of detailed modelling. This problem, which must be overcome in order to accurately model transient combustion systems, can be analyzed in terms of the multiple time scales, multiple space scales, geometric complexity, and physical complexity of the systems to be modelled. [Pg.333]

Using the techniques of analytic geometry, let us derive the Freundlich constants in a little more detail than used in the derivation of the constants in the discussion of reverse osmosis treated previously. As mentioned, the straight-line form of the equation requires only two experimental data points however, experiments are normally conducted to produce not just two pair of values but more. Thus, the experimental resnlts must be reduced to just the two pairs of values required for the determination of the parameters therefore, assuming there are m pairs of values, these m pairs must be reduced to just two pairs. Once the reduction to two pairs has been done, the isotherm equation may be then be written to just the two pairs of derived values as follows ... [Pg.410]


See other pages where Geometry derivative equation parameters is mentioned: [Pg.334]    [Pg.190]    [Pg.233]    [Pg.267]    [Pg.135]    [Pg.120]    [Pg.23]    [Pg.103]    [Pg.577]    [Pg.388]    [Pg.88]    [Pg.138]    [Pg.707]    [Pg.19]    [Pg.69]    [Pg.204]    [Pg.20]    [Pg.156]    [Pg.332]    [Pg.59]    [Pg.97]    [Pg.269]    [Pg.320]    [Pg.573]    [Pg.94]    [Pg.131]    [Pg.242]    [Pg.316]    [Pg.346]    [Pg.184]    [Pg.584]    [Pg.366]    [Pg.21]    [Pg.46]    [Pg.183]    [Pg.8]    [Pg.171]    [Pg.175]    [Pg.259]    [Pg.94]    [Pg.24]    [Pg.8]    [Pg.78]    [Pg.1108]    [Pg.19]    [Pg.192]    [Pg.217]   
See also in sourсe #XX -- [ Pg.56 ]




SEARCH



Derivatives equations

Equation derivation

Geometry parameters

© 2024 chempedia.info