Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Floatation test

How do air bubbles appearing on the surface of the sample affect floatation test ... [Pg.185]

Floatation Test Floats in Li Sinks in LI Floats in L2 Sinks in Floats in L3 Sinks in L3 Sinks in Li Floats or sinks in L,... [Pg.190]

Floatation Test Sinks in L Floats or sinks in L2 Sinks in L2 Floats in L3 Sinks in Lj Floats in L2 Sinks in Lj Floats in Lj Sinks in L2 Floats in L3... [Pg.192]

Floatation test Sinks in Floats in Lo Sinks in Floats in Li Sinks in Lj Sinks or floats in L2 Sinks in Li Sinks or floats inL2... [Pg.194]

Because of gas bubbles entrapped in tlicir body, foams have lower apparent density. So, floatation test is not applicable. [Pg.283]

Neumann and co-workers have used the term engulfrnent to describe what can happen when a foreign particle is overtaken by an advancing interface such as that between a freezing solid and its melt. This effect arises in floatation processes described in Section Xni-4A. Experiments studying engulfrnent have been useful to test semiempirical theories for interfacial tensions [25-27] and have been used to estimate the surface tension of cells [28] and the interfacial tension between ice and water [29]. [Pg.352]

The two reactors were operated from 27 March, 2007 to 2 August 2007. During this period, the temperature was well controlled from 38 to 42° C. Little effect of the minor temperature fluctuation was found to the oil field wastewater treatment efficiency. For the first 7 days, the biological reactors were filled with heavy oil wastewater which have pretreated by gas floatation and the air blowers turned on, the electric heater turned on, but with the influent and effluent stream valves closed. The first test was for hydraulic retention time (HRT) of 36 h with a constant wastewater flow through each reactor at 0.4 L min T Then the HRT was successively reduced in 4h increments from 36 to 8 h and the effluent water quahty was detected simultaneously, while adjusting the influent flux to ensure tiiat tiie oil component in the effluent stream was consistent. [Pg.249]

The following risk assessment involves testing the proposal to fit mandatory automatic floatation equipment to the skids of helicopters against the principles outlined in this book and to apply the ALARP principle to the findings. [Pg.250]

In film floatation, which was developed by Fuerste-nau and co-workers (59, 60), particles of similar size are sprinkled on the surface of a liquid with a known surface tension and the fraction of particles that sink into the liquid is measured. From this, the critical wetting surface tension, (of Zisman), of solid particles (i.e. the liquid surface tension at which the solid surface is completely wetted by the test liquid) can be determined. [Pg.269]

After the physieal stmctuie and peripherals are properly shown, severe experiments will be eonducted for ealibration and testing of the sensory system, floatation eontrol, navigation, and... [Pg.197]

In a typical test sample, two layers of polymer are placed in contact with one another to make a bilayer sample, or diffusion couple. If the polymers are different, then it may he possible to prepare a bilayer sample by sequential spin-casting with different solvents. For example, a diffusion couple of PMMA and PEO can be made by spin-casting PEO from methanol onto a PMMA film that was spin-cast from a toluene solution. For self-diffusion, or interdiffiision between similar polymers of different molecular weight, the second layer must normally be transferred from a separate substrate onto the first layer via floatation on high-purity water. [Pg.670]


See other pages where Floatation test is mentioned: [Pg.184]    [Pg.185]    [Pg.184]    [Pg.185]    [Pg.100]    [Pg.1138]    [Pg.149]    [Pg.1902]    [Pg.192]    [Pg.509]    [Pg.49]   
See also in sourсe #XX -- [ Pg.184 ]




SEARCH



FLOATATION

© 2024 chempedia.info