Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Fixing design right

Figure 5.21. Bifok/Tecator FIAstar 5020 Analyzer (center) shown with the 5032 Detector System (left) and the 5007 Sampler (right). Comprising two independently programmable peristaltic pumps and injection valves, the analyzer applies small dedicated, ready-to-use chemical manifolds with fixed designs (Chemifolds), which are easily interchangeable. The compartment of the analyzer can be thermostated. Figure 5.21. Bifok/Tecator FIAstar 5020 Analyzer (center) shown with the 5032 Detector System (left) and the 5007 Sampler (right). Comprising two independently programmable peristaltic pumps and injection valves, the analyzer applies small dedicated, ready-to-use chemical manifolds with fixed designs (Chemifolds), which are easily interchangeable. The compartment of the analyzer can be thermostated.
The algorithm contains five minimisation procedures which are performed the same way as in the method " i.e. by minimisation of the RMS between the measured unidirectional distribution and the corresponding theoretical distribution of die z-component of the intensity of the leakage field. The aim of the first minimisation is to find initial approximations of the depth d, of the crack in the left half of its cross-section, die depth d in its right half, its half-width a, and the parameter c. The second minimisation gives approximations of d, and d and better approximations of a and c based on estimation of d,= d, and d,= d,j. Improved approximations of d] and d4 are determined by the third minimisation while fixing new estimations of d dj, dj, and dj. Computed final values dj , d/, a and c , whieh are designated by a subscript c , are provided by the fourth minimisation, based on improved estimations of d, dj, dj, and d . The fifth minimisation computes final values d, , d, dj, d while the already computed dj , d/, a and c are fixed. [Pg.688]

Figure 12-5F. Lubricated and nonlubricated balanced opposed process reciprocating compressors, designed to API 618 code. Fixed- and variable-speed drives using gas or diesel engines, steam or gas turbines, or electric motor. Note power drive to connect to right side of cross-head box in center. (Used by permission Bui. PROM 635/115/95-11. Nuovo Pignone S. P. A., Florence, Italy New York Los Angeles and Houston, Texas. All rights reserved.)... Figure 12-5F. Lubricated and nonlubricated balanced opposed process reciprocating compressors, designed to API 618 code. Fixed- and variable-speed drives using gas or diesel engines, steam or gas turbines, or electric motor. Note power drive to connect to right side of cross-head box in center. (Used by permission Bui. PROM 635/115/95-11. Nuovo Pignone S. P. A., Florence, Italy New York Los Angeles and Houston, Texas. All rights reserved.)...
The hydraulic design is described by two components the type of fluid outlet and the flow distribution. A 3 x 3 matrix of orifice types and flow distributions defines 9 numeric hydraulic design codes. The orifice type varies from changeable jets to fixed ports to open throat from left to right in the matrix. The flow distribution varies from bladed to ribbed to open face from top to bottom. There is usually a close correlation between the flow distribution and the cutter arrangement. [Pg.806]

Suppose you have six balls with three different colors, three red, two blue, one yellow. Balls of the same color cannot be distinguished. In how many ways can you assign the six balls to the six vertices of an octahedron which moves freely in spacel If the octahedron is fixed in space in such a way that the vertices are designated as upper, lower, front, back, left, and right vertex, then the number is determined by basic permutation principles as... [Pg.2]

The left-hand side of equation (2.28) is a function only of t, while the right-hand side is a function only of x. Since x and t are independent variables, each side of equation (2.28) must equal a constant. If this were not true, then the left-hand side could be changed by varying t while the right-hand side remained fixed and so the equality would no longer apply. For reasons that will soon be apparent, we designate this separation constant by E and assume that it is a real number. [Pg.46]

State properties, of mixtures, 24 671-672 State right to know (RTK) laws, ink regulation under, 14 332 State safety acts/regulations, 21 830-831 States, change in entropy between, 24 649 State variables, to fix the properties of a mixture, 24 681—682 STATGRAPHICS plus 5 (quality and design)... [Pg.882]

Compost bins can be purchased or homemade, and are preferably made from recycled or reused materials. As long as it fulfills the basic criteria right), the design choice is yours. Choose one that suits your needs and garden. Place it in an accessible spot, directly on bare ground. It can have a fixed site or, depending on the model, it can be moved to different parts of the garden between batches. [Pg.41]

If the observed order of priority of the remaining three functions ( b > c) is in a clockwise direction, the absolute configuration is designated R (rectus or right) if counterclockwise, fixe configuration is S (sinister or left). Diasteteomers which differ at a single stereocentei are called epimers. [Pg.1266]

Fig. 25. Energy contours for poly-L-alanine helices, in kcal mole-1. The symbols R and L indicate the positions of the right- and left-handed a-helices the symbols fix and /Ja designate the positions of the parallel and antiparallel pleated-sheet structures (Ooi et al., 1967). Fig. 25. Energy contours for poly-L-alanine helices, in kcal mole-1. The symbols R and L indicate the positions of the right- and left-handed a-helices the symbols fix and /Ja designate the positions of the parallel and antiparallel pleated-sheet structures (Ooi et al., 1967).
The provision of the right amounts of educts at the reaction site, the establishment and the maintenance of the adequate reaction conditions and the in-time removal of the reaction products are tasks that are not necessarily solved optimally in standard fixed-bed reactor configurations Novel designs to improve the interaction of transport and reaction have therefore attracted considerable interest m recent years They can be placed under the heading multifunctional reactors [50-52]... [Pg.445]


See other pages where Fixing design right is mentioned: [Pg.6]    [Pg.51]    [Pg.320]    [Pg.50]    [Pg.383]    [Pg.806]    [Pg.49]    [Pg.276]    [Pg.637]    [Pg.67]    [Pg.6]    [Pg.229]    [Pg.261]    [Pg.273]    [Pg.280]    [Pg.287]    [Pg.4]    [Pg.286]    [Pg.31]    [Pg.222]    [Pg.105]    [Pg.303]    [Pg.91]    [Pg.100]    [Pg.130]    [Pg.754]    [Pg.237]    [Pg.7]    [Pg.170]    [Pg.94]    [Pg.43]    [Pg.65]    [Pg.320]    [Pg.513]    [Pg.225]    [Pg.136]    [Pg.14]    [Pg.348]    [Pg.137]   
See also in sourсe #XX -- [ Pg.108 ]

See also in sourсe #XX -- [ Pg.108 ]




SEARCH



Design rights