Fixed frequency

Two major sources of ultrasound are employed, namely ultrasonic baths and ultrasonic immersion hom probes [79, 71]- The fonuer consists of fixed-frequency transducers beneath the exterior of the bath unit filled with water in which the electrochemical cell is then fixed. Alternatively, the metal bath is coated and directly employed as electrochemical cell, but m both cases the results strongly depend on the position and design of the set-up. The ultrasonic horn transducer, on the other hand, is a transducer provided with an electrically conducting tip (often Ti6A14V), which is inuuersed in a three-electrode thenuostatted cell to a depth of 1-2 cm directly facing the electrode surface. [Pg.1942]

The ultrasound intensity and the distance between the hom and the electrode may be varied at a fixed frequency, typically of 20 kHz. This cell set-up enables reproducible results to be obtained due to the fonuation of a macroscopic jet of liquid, known as acoustic streaming, which is the main physical factor in detenuinmg tire magnitude of the observed current. [Pg.1942]

Utdity power distribution grids normally operate at a fixed frequency of 50 or 60 Hz. These frequencies can be utilized directiy for the induction process if the load characteristics are appropriate. If they are not, specific appHcations can be optimized by the use of variable and higher frequencies produced by soHd-state frequency power converters connected between the supply and the load. [Pg.126]

Another resonant frequency instmment is the TA Instmments dynamic mechanical analy2er (DMA). A bar-like specimen is clamped between two pivoted arms and sinusoidally oscillated at its resonant frequency with an ampHtude selected by the operator. An amount of energy equal to that dissipated by the specimen is added on each cycle to maintain a constant ampHtude. The flexural modulus, E is calculated from the resonant frequency, and the makeup energy represents a damping function, which can be related to the loss modulus, E". A newer version of this instmment, the TA Instmments 983 DMA, can also make measurements at fixed frequencies as weU as creep and stress—relaxation measurements. [Pg.199]

Variable voltage (fixed frequency) static control Figure 6.40 Energy conservation through static control... [Pg.137]

DC voltage to fixed frequency and voltage supply inverter... [Pg.142]

Phase modulated PWM forwardmode full bridge Fixed frequency... [Pg.72]

One last form of voltage-mode eontrol is very rudimentary. It eould be ealled hysteretic voltage-mode. In this form of eontrol, a fixed frequency oscillator is gated ON only when the output voltage has fallen to below a limit dictated by the voltage feedback loop. It is sometimes called hiccup-mode because the power switch occasionally bursts on and then returns to a constant off state. [Pg.73]

Variable Frequency Control. At light loads, fixed frequency control methods loose efficiency because of the fixed switching losses. Some controllers will... [Pg.74]

DMTA is based on the response of a viscoelastic material to an oscillatory excitation. Considering a fixed frequency, while the temperature is changed, there will... [Pg.392]

Plant and equipment that require a service on completion of a certain specified period of hours may, through experience, be catered for on a fixed frequency basis. If employed, this method avoids the need to record running hours (or, in the case of transport, mileage) on a daily or weekly basis to schedule the relevant planned maintenance. If it is essential that the maintenance of the plant and equipment be carried out on the completion of a certain number of operating hours or mileage, then this must be allowed for in the allocated work hours of the relevant trade group. [Pg.787]

A technique for performing dynamic mechanical measurements in which the sample is oscillated mechanically at a fixed frequency. Storage modulus and damping are calculated from the applied strain and the resultant stress and shift in phase angle. [Pg.639]

It is clear that this data treatment is strictly valid providing the tested material exhibits linear viscoelastic behavior, i.e., that the measured torque remains always proportional to the applied strain. In other words, when the applied strain is sinusoidal, so must remain the measured torque. The RPA built-in data treatment does not check this y(o )/S (o)) proportionality but a strain sweep test is the usual manner to verify the strain amplitude range for constant complex torque reading at fixed frequency (and constant temperature). [Pg.820]

Microwaves have wavelengths between 1 mm and 1 m and hence have similar frequencies to radar and telecommunication devices. So as not to cause interference with these systems the frequency of radiation that can be emitted by household and industrial appliances is strictly regulated, with most appliances operating at a fixed frequency of 2.45 GHz. To some extent this reduces the flexibility of such equipment. [Pg.220]

Fast Fourier transform (FFT) A procedure for carrying out Fourier transformation at high speed, with a minimum of storage space being used. Field frequency lock The magnitude of the field Bq is stabilized by locking onto the fixed frequency of a resonance in the solution, usually of the solvent. [Pg.414]

The above considerations concern a reversible electrodic process, ox + ne red as instead of 20-100 hz in the sinusoidal technique a fixed frequency of 225 Hz is normally used in the square-wave mode, the chance of irreversibility in the latter becomes greater, which then appears as asymmetry of the bellshaped I curve. Such a phenomenon may occur more especially when the complete i versus E curve is recorded on a single drop, a technique which has appeared useful51 in cases of sufficient reversibility. [Pg.172]

The transducers operate at a fixed frequency of irradiation emitting radiations through a fixed area of irradiation. Thus, the type of transducer coupled with the total area of irradiation and the operating frequency are the key factors in the efficient design of the sonochemical reactors. The three main types of transducers are gas driven, liquid driven and electromechanical transducers out of which the electromechanical transducers are by far the most versatile and widely used. [Pg.38]

When the light is dominated by massive stars, e.g. in starburst galaxies, the luminosity is related in turn to the rate of metal production, since virtually all processed material is ejected in the form of metals (and some helium). Thus there is a relationship between the total co-moving luminosity density, the monochromatic luminosity density (deduced from star-forming galaxy redshift surveys with appropriate corrections for absorption) in a fixed frequency bandwidth (anywhere between 912 and about 2000 A in the rest frame) and the mass going into nucleosynthesis ... [Pg.381]

Experimentally there are two alternatives. One is to fix the magnetic field that determines the Larmor frequency and to sweep the radiation frequency through this value. Alternatively radiation at a fixed frequency is used while the field sweeps through the resonance value. When the resonance condition is reached absorption of radiation occurs. [Pg.289]


See other pages where Fixed frequency is mentioned: [Pg.286]    [Pg.802]    [Pg.805]    [Pg.1164]    [Pg.1248]    [Pg.1294]    [Pg.1564]    [Pg.2444]    [Pg.2448]    [Pg.2496]    [Pg.402]    [Pg.315]    [Pg.316]    [Pg.316]    [Pg.141]    [Pg.141]    [Pg.916]    [Pg.74]    [Pg.492]    [Pg.110]    [Pg.235]    [Pg.116]    [Pg.585]    [Pg.586]    [Pg.216]    [Pg.296]    [Pg.298]    [Pg.363]    [Pg.10]    [Pg.107]    [Pg.440]    [Pg.468]   