Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Final readout

Polycarbonate compact discs have also been used as supports for microarray development [112]. The microarray is generated using an inkjet applicator that employs an electric current to dispense monodisperse droplets containing antibodies onto the disk. The sensing reaction is based on competitive inhibition immunoassays using fluorescent antibodies and final readout is accomplished using a fluorescence scanner. [Pg.219]

A very interesting proposal using Magnetic Resonance Force Microscopy (MRFM) was made by Berman and co-workers in 2000 [35], In that paper it is shown that through single-spin electron measurement and electron-nucleus hyperfine coupling, NMR quantum computation could be implemented, including the steps of initial state preparation, unitary transformations and final readout. [Pg.6]

Personal Errors Finally, analytical work is always subject to a variety of personal errors, which can include the ability to see a change in the color of an indicator used to signal the end point of a titration biases, such as consistently overestimating or underestimating the value on an instrument s readout scale failing to calibrate glassware and instrumentation and misinterpreting procedural directions. Personal errors can be minimized with proper care. [Pg.60]

Two properties, in particular, make Feynman s approach superior to Benioff s (1) it is time independent, and (2) interactions between all logical variables are strictly local. It is also interesting to note that in Feynman s approach, quantum uncertainty (in the computation) resides not in the correctness of the final answer, but, effectively, in the time it takes for the computation to be completed. Peres [peres85] points out that quantum computers may be susceptible to a new kind of error since, in order to actually obtain the result of a computation, there must at some point be a macroscopic measurement of the quantum mechanical system to convert the data stored in the wave function into useful information, any imperfection in the measurement process would lead to an imperfect data readout. Peres overcomes this difficulty by constructing an error-correcting variant of Feynman s model. He also estimates the minimum amount of entropy that must be dissipated at a given noise level and tolerated error rate. [Pg.676]

Finally a word about efficiency observing time on large telescopes is a valuable asset, both in terms of cost and considering the ratio of observing time available to the time requested by astronomers. Marco et al. (2001) state that the observing efficiency defined as fhe ratio of science shutter time to available dark time is 10-30% for the ADONIS AO system while the corresponding ratio for other instruments is 50-80%. Some of this difference is due to the fact that most AO exposures are of short duration and the readout time is significant. In addition, AO systems use time to close the loop and optimize performance. Observations may also be necessary to characterize the PSF. [Pg.204]

Switch on the modules for autoanalysis and commence pumping reagents. The wash solution is saturated benzoic acid. Load the standards into a sample tray and analyse at a rate of 20 samples per hour, adjusting the sensitivity of the detection-readout to bring the baseline and top standards on scale. If the samples are all low, the sensitivity should be increased and appropriate lower standards used. After a baseline, analyse a tray of samples plus standards, and follow with a baseline before analysing the second tray of samples and standards. Conclude by aspirating the wash solution to obtain a final baseline. [Pg.136]

In the second section of this chapter, strategies to identify substrates for biochemical protease assays are discussed. Section 2.3 focuses on theoretical and practical aspects of various fluorescence-based readouts for biochemical protease assays. Finally concrete experiments for the determination of enzyme kinetics relevant for the development of robust and sensitive biochemical protease assays are summarized in Section 2.4. Altogether this chapter offers guidelines for the development of biochemical protease assays for the purpose of protease inhibitor-directed drug discovery. [Pg.27]


See other pages where Final readout is mentioned: [Pg.262]    [Pg.154]    [Pg.156]    [Pg.225]    [Pg.161]    [Pg.161]    [Pg.114]    [Pg.123]    [Pg.31]    [Pg.108]    [Pg.169]    [Pg.46]    [Pg.674]    [Pg.226]    [Pg.229]    [Pg.231]    [Pg.83]    [Pg.258]    [Pg.262]    [Pg.154]    [Pg.156]    [Pg.225]    [Pg.161]    [Pg.161]    [Pg.114]    [Pg.123]    [Pg.31]    [Pg.108]    [Pg.169]    [Pg.46]    [Pg.674]    [Pg.226]    [Pg.229]    [Pg.231]    [Pg.83]    [Pg.258]    [Pg.246]    [Pg.164]    [Pg.68]    [Pg.218]    [Pg.952]    [Pg.412]    [Pg.257]    [Pg.212]    [Pg.96]    [Pg.153]    [Pg.206]    [Pg.390]    [Pg.19]    [Pg.70]    [Pg.199]    [Pg.293]    [Pg.176]    [Pg.14]    [Pg.66]    [Pg.232]    [Pg.136]    [Pg.219]    [Pg.93]    [Pg.179]    [Pg.43]   
See also in sourсe #XX -- [ Pg.226 ]




SEARCH



Readout

© 2024 chempedia.info