Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Factor fast transient signals

Leach, A. M. and Hieftje, G. M. (2002) Factors affecting the prodnction of fast transient signals in single shot laser ablation indnctively conpled plasma mass spectrometry. Appl Spectrosc., 56, 62. [Pg.83]

The best anti-surge control is the simplest and most basic that will do the job. The most obvious parameter is minimum-flow measurement, or if there is a relatively steep pressure-flow characteristic, the differentia pressure may be used. The latter parameter allows for a much faster response system, as flow measurement response is generally slow however, the speed of response need only be fast enough to accept expected transients. One major problem with the conventional methods of measurement and control is the need to move the set point for initiation of the control signal away from the exact surge point to allow some safety factor for control response time and other parameters not directly included... [Pg.364]

Optical absorption spectrophotometry is probably the most commonly used technique [4,a]. Reaction cells are similar to those used in flash work. Photomultipliers cover the uv-visible range the initial photoelectric signal is amplified internally, by an amoimt controlled by selection of the number of dynodes. Nanosecond equipment is commercially available. Picosecond time-resolution has been achieved [l,h]. For the infrared and Raman region, semiconductor photodiodes cover the range 400-3000 nm the vibrational spectra yield structural information about transient species much more detailed and precise than that from electronic spectra. Resonance enhancement of Raman spectra increases their intensity by a factor of 10, and makes them attractive for detection and monitoring [4,b]. They can be recorded with time-resolution down to sub-nanoseconds. Fluorescence detection is sensitive, and fast with single-photon counting or a streak camera (Section 4.2.4.2), it has been used for times down to 30 ps after an electron pulse. Conductivity also provides a fast and sensitive technique [4,c,d,l,m], especially in hydrocarbon solutions, where... [Pg.123]


See other pages where Factor fast transient signals is mentioned: [Pg.450]    [Pg.590]    [Pg.20]    [Pg.319]    [Pg.103]    [Pg.405]    [Pg.1067]    [Pg.169]    [Pg.502]    [Pg.23]    [Pg.4]    [Pg.402]    [Pg.280]    [Pg.145]    [Pg.750]    [Pg.276]    [Pg.203]    [Pg.490]    [Pg.36]    [Pg.546]    [Pg.929]   


SEARCH



Fast transient signals

Signaling factor

© 2024 chempedia.info