Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Emergency planning response guidelines

The results indicate that 2000 people will be exposed to a concentration of ammonia greater than the emergency response planning guideline concentration (e.g., ERPG-2). [Pg.15]

AIIIA Emergency Response Planning Guidelines (ERPGs) ERPG-1 ERPG-2 ERPG-3 0.1 ppm 30 ppm 100 ppm AIHA 1991... [Pg.171]

AIHA. 1991. Emergency response planning guidelines Hydrogen sulfide. American Industrial Hygiene Association. Fairfax, VA. [Pg.175]

Table 5-6 Emergency Response Planning Guidelines (ERPGs)1 (all values are in ppm unless otherwise noted) ... Table 5-6 Emergency Response Planning Guidelines (ERPGs)1 (all values are in ppm unless otherwise noted) ...
AIHA, Emergency Response Planning Guidelines and Workplace Environmental Exposure Levels (Fairfax, VA American Industrial Hygiene Association, 1996). [Pg.202]

The Dow indexes are useful for determining equipment spacing requirements. The F EI uses an empirical correlation based entirely on the F EI value to estimate the radius of exposure. It is assumed that any equipment located outside this distance would not be damaged by a fire or explosion. The CEI estimates the hazard distance for chemical exposure based on the emergency response planning guideline (ERPG) values for the particular material released. [Pg.442]

Emergency response, to hazardous materials incidents, 25 343 Emergency Response Planning Guidelines (ERPGs), for sulfuric acid, 23 795 values in, 13 156 Emery, dental abrasive, 8 339 Emetine, 2 74, 100 (—)-Emetine, 2 84, 85 Emission, from OLEDs, 22 215, 218-219. See also Emissions... [Pg.312]

Figure 6 Cloud footprint to an atmospheric concentration of 20 ppm resulting from the rupture of a 50-mm-diameter chlorine pipe containing either chlorine liquid or chlorine vapor. Release conditions Complete rupture of pipe without shutoff, pipe elevation is 5 m above grade, wind speed is 5 m/sec, atmospheric stability class D, 20 ppm is the Emergency Response Planning Guideline-3 (ERPG-3) concentration for chlorine, the concentration at which life-threatening effects might result from exposure for 1 hour. Figure 6 Cloud footprint to an atmospheric concentration of 20 ppm resulting from the rupture of a 50-mm-diameter chlorine pipe containing either chlorine liquid or chlorine vapor. Release conditions Complete rupture of pipe without shutoff, pipe elevation is 5 m above grade, wind speed is 5 m/sec, atmospheric stability class D, 20 ppm is the Emergency Response Planning Guideline-3 (ERPG-3) concentration for chlorine, the concentration at which life-threatening effects might result from exposure for 1 hour.
Other means of evaluating the toxic effects of vapors, and their potential impact on exposed people, can be found in the Emergency Response Planning Guidelines for Air Contaminants (ERPGs), issued by the American Industrial Hygiene Association (1992). The documents define values of exposure to toxic vapors needed to produce specific health effects. Three levels of vapor concentration are defined ... [Pg.40]

For illustrative purposes, the hazardous properties of the materials used in the examples have been modeled to the Emergency Response Planning Guideline, ERPG-2 (see Section 3.1.1) concentration for toxic materials, or to one half of the lower flammable limit (LFL/2) for flammable material. Lastly, only the first 3600 seconds of the event are considered in these examples. For an actual situation, different concentration levels for toxic or flammable concentrations may be considered and different durations as well. [Pg.147]


See other pages where Emergency planning response guidelines is mentioned: [Pg.193]    [Pg.179]    [Pg.183]    [Pg.231]    [Pg.74]    [Pg.76]    [Pg.359]    [Pg.173]    [Pg.64]    [Pg.113]    [Pg.157]    [Pg.9]    [Pg.200]    [Pg.648]    [Pg.31]    [Pg.32]    [Pg.226]    [Pg.72]    [Pg.273]    [Pg.460]    [Pg.10]    [Pg.12]    [Pg.193]    [Pg.18]    [Pg.491]    [Pg.18]    [Pg.41]   
See also in sourсe #XX -- [ Pg.529 ]

See also in sourсe #XX -- [ Pg.597 ]




SEARCH



Emergency Response Planning Guidelines Level

Emergency Response Planning Guidelines for Air Contaminants

Emergency Response Planning Guidelines for Air Contaminants ERPG)

Emergency response planning

Emergency response planning guidelines ERPGs)

© 2024 chempedia.info