Elution bands

The relatively large values of Vmax indicate, however, that the separation will be lengthy and the elution bands broad, particularly for the bromide band. The use of a more concentrated solution of eluant significantly reduces the values °f Vmax and the elution bands become much sharper. Thus the distribution coefficient for bromide using a 0.35M potassium nitrate solution is 6.5 and using the same column, Vmax = (6.5 x 4) + 4 = 30 mL. [Pg.197]

As explained before, the scores of the spectra can be plotted in the space defined by the two principal components of the data matrix. The appearance of the scores plot depends on the way the rows (spectra) and the columns have been normalized. If the spectra are not normalized, all spectra are situated in a plane (see Fig. 34.5). From the origin two straight lines depart, which are connected by a curved line. We have already explained that the straight line segments correspond with the pure spectra which are located in the wings of the elution bands (selective retention time... [Pg.260]

More recently, there have been attempts to study band patterns as they are affected by shock layers in nonlinear chromatography.42 Shock layers are steep boundaries that develop when the boundary front of an elution band becomes very steep and self-sharpening at high concentrations. While comparison of predicted and experimental data was promising, this study, like the others mentioned above, was done with single-component samples and awaits further analysis with the kinds of multi-component feeds more frequently encountered in process purifications. [Pg.112]

On the negative side, there is excessive broadening of the elution band caused by a number of features including the heterogeneity of the imprint as noted earlier. [Pg.511]

Analytichem International has taken trace enrichment a step further with the development of the Analytichem Automated Sample Preparation LC Module, A ASP LCM. This unit uses derivatized silica in specially configured cassettes on which the sample is off-line enriched by using an inexpensive vacuum manifold. After enrichment, the cassette is placed in the unit, which holds up to 10 cassettes containing 10 samples each, and the enriched samples are eluted directly on the analytical column. Provisions allow for early- and late-eluting bands to be switched to waste. The unit also provides for external control of... [Pg.118]

In this system the bands (zones) broaden because of diffusion effects and nonequilibrium. This broadening mechanism is fairly symmetrical and the resulting elution bands approach the shape of a Gaussian curve. This system best explains liquid or gas partition chromatography. The system may be viewed in two ways ... [Pg.12]

Efficiency (N)—A measure of the narrowness of elution bands, the sharpness of peaks, and the performance of a column. Results are in theoretical plates. The Huber equation calculates efficiency versus flow rate, which is plotted on as a Van Deampter plot, which compares column efficiency with flow rate. [Pg.215]

Chromatograms of the optical resolution of (I) and (II) Eire shown in Figure. 1. Compound (II) is completely resolved into its enantiomers chromatographically. The g-factor remains at its constant optimum value throughout the elution band of each enantiomer. Compound (I) in contrast is incompletely resolved, giving a single absorbance elution band, but a double bisignate difference absorbance band. The fractions of (I) eluted in the volume between the vertical dashed lines are incompletely resolved. Values for the g-max factors have been determined from the CD and absorption spectra of (I) and (II). [Pg.284]

Initial work on the assay for this metabolite using normal phase HPLC as was developed for I was impractical due to the polar nature of VI. Using such systems resulted in long analysis time, broad eluting bands, as well as poor sensitivity for the polar metabolite. These findings led then to an investigation of reverse-phase HPLC for analysis of this metabolite. [Pg.193]

This work used elution development with buffers of a-hydroxyiso-butyric acid partially neutralized with NHi OH, and Dowex 50W-X12 resin with a particle size range of 20—40 ym. The elution bands showed good separation of Es, Cf, Bk (the band labelled "3" is a combination of Bk and Eu), and Cm. The very small amount of Fm present in this early production material is in the extreme leading edge of the Es band. [Pg.188]

A. Quantitative Determinations. One of the three isocratic separations could also be used for a quantitative determination of the amounts of FD C Blue 1 and Red 40 present in the powdered drink mix. A spectrophotometer would be needed. After scanning to determine the best wavelength for the analysis of each dye, measurements on standard solutions could be used to construct a calibration curve. The isocratic separation could then be performed, and the entire band containing each dye could be collected and diluted accurately to an appropriate volume. With the volume of the eluted bands known, the mass of dye can be calculated. [Pg.329]

Finally, if only the separation of early-eluted bands is unsatisfactory, the overall sample separation can be possibly improved by using gradient elution with increasing elution strength during the course of separation (see Section 1.5). [Pg.56]


See other pages where Elution bands is mentioned: [Pg.63]    [Pg.160]    [Pg.276]    [Pg.275]    [Pg.257]    [Pg.603]    [Pg.761]    [Pg.762]    [Pg.763]    [Pg.111]    [Pg.126]    [Pg.305]    [Pg.366]    [Pg.182]    [Pg.183]    [Pg.500]    [Pg.452]    [Pg.7]    [Pg.220]    [Pg.291]    [Pg.563]    [Pg.166]    [Pg.167]    [Pg.176]    [Pg.378]    [Pg.233]    [Pg.63]    [Pg.106]    [Pg.107]    [Pg.145]    [Pg.165]    [Pg.191]    [Pg.181]    [Pg.322]    [Pg.329]    [Pg.347]    [Pg.915]    [Pg.464]    [Pg.509]   
See also in sourсe #XX -- [ Pg.195 ]




SEARCH



Band broadening gradient elution

Elution of a Narrow Band with Competitive Langmuir Isotherms

Elution of a Wide Band With Competitive Langmuir Isotherms