Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Electron nuclear double resonance spectroscopy ENDOR

B1.15.5.1 ELECTRON-NUCLEAR DOUBLE RESONANCE SPECTROSCOPY (ENDOR)... [Pg.1567]

Figure 1 First-derivative spectra obtained by continuous-wave techniques for the phenalenyl radical (A) ESR, (B) ENDOR, (C) special TRIPLE resonance, (D) general TRIPLE resonance, and (E) ENDOR-induced ESR. The arrows indicate the positions of the RF pumping frequencies there are several possibilities in (D). The RF pumping frequency in (E) is set in the same position as shown in (B). (Reprinted from Kurreck H, Kirste B, and Lubitz W (1988) Electron Nuclear Double Resonance Spectroscopy of Radicals In Solution. Weinheim VCH Publishers.)... Figure 1 First-derivative spectra obtained by continuous-wave techniques for the phenalenyl radical (A) ESR, (B) ENDOR, (C) special TRIPLE resonance, (D) general TRIPLE resonance, and (E) ENDOR-induced ESR. The arrows indicate the positions of the RF pumping frequencies there are several possibilities in (D). The RF pumping frequency in (E) is set in the same position as shown in (B). (Reprinted from Kurreck H, Kirste B, and Lubitz W (1988) Electron Nuclear Double Resonance Spectroscopy of Radicals In Solution. Weinheim VCH Publishers.)...
ENDOR electron nuclear double resonance spectroscopy... [Pg.157]

Double-resonance spectroscopy involves the use of two different sources of radiation. In the context of EPR, these usually are a microwave and a radiowave or (less common) a microwave and another microwave. The two combinations were originally called ENDOR (electron nuclear double resonance) and ELDOR (electron electron double resonance), but the development of many variations on this theme has led to a wide spectrum of derived techniques and associated acronyms, such as ESEEM (electron spin echo envelope modulation), which is a pulsed variant of ENDOR, or DEER (double electron electron spin resonance), which is a pulsed variant of ELDOR. The basic principle involves the saturation (partially or wholly) of an EPR absorption and the subsequent transfer of spin energy to a different absorption by means of the second radiation, leading to the detection of the difference signal. The requirement of saturability implies operation at close to liquid helium, or even lower, temperatures, which, combined with long experimentation times, produces a... [Pg.226]

Since the phenoxyls possess an S = ground state, they have been carefully studied by electron paramagnetic spectroscopy (EPR) and related techniques such as electron nuclear double resonance (ENDOR), and electron spin-echo envelope modulation (ESEEM). These powerful and very sensitive techniques are ideally suited to study the occurrence of tyrosyl radicals in a protein matrix (1, 27-30). Careful analysis of the experimental data (hyperfine coupling constants) provides experimental spin densities at a high level of precision and, in addition, the positions of these tyrosyls relative to other neighboring groups in the protein matrix. [Pg.155]

To resolve hf and nuclear quadrupole interactions which are not accessible in the EPR spectra, George Feher introduced in 1956 a double resonance technique, in which the spin system is simultaneously irradiated by a microwave (MW) and a radio frequency (rf) field3. This electron nuclear double resonance (ENDOR) spectroscopy has widely been applied in physics, chemistry and biology during the last 25 years. Several monographs2,4 and review articles7 11 dealing with experimental and theoretical aspects of ENDOR have been published. [Pg.122]

Electron-nuclear double resonance (ENDOR) spectroscopy A magnetic resonance spectroscopic technique for the determination of hyperfine interactions between electrons and nuclear spins. There are two principal techniques. In continuous-wave ENDOR the intensity of an electron paramagnetic resonance signal, partially saturated with microwave power, is measured as radio frequency is applied. In pulsed ENDOR the radio frequency is applied as pulses and the EPR signal is detected as a spin-echo. In each case an enhancement of the EPR signal is observed when the radiofrequency is in resonance with the coupled nuclei. [Pg.250]

The new techniques of phosphorescence-microwave multiplet resonance spectroscopy with optical detection have been reviewed by El-Sayed and Kwiram Such exciting experiments as the optical detection on electron-nuclear double resonance (ENDOR) and of electron-electron double resonance (EEDOR) in zero magnetic field have been achieved, and it is certain that much detailed knowledge concerning the phosphorescent states will evolve from this field. [Pg.44]


See other pages where Electron nuclear double resonance spectroscopy ENDOR is mentioned: [Pg.109]    [Pg.24]    [Pg.6]    [Pg.282]    [Pg.109]    [Pg.24]    [Pg.6]    [Pg.282]    [Pg.89]    [Pg.367]    [Pg.385]    [Pg.55]    [Pg.2245]    [Pg.2560]    [Pg.2779]    [Pg.121]    [Pg.391]    [Pg.2244]    [Pg.2559]    [Pg.2778]    [Pg.7]    [Pg.157]    [Pg.323]    [Pg.1548]    [Pg.1567]    [Pg.300]    [Pg.160]    [Pg.21]    [Pg.19]    [Pg.236]    [Pg.70]    [Pg.562]    [Pg.93]    [Pg.132]   
See also in sourсe #XX -- [ Pg.76 , Pg.129 , Pg.131 , Pg.137 , Pg.138 , Pg.243 , Pg.282 , Pg.289 , Pg.367 ]




SEARCH



Double resonance

Double resonance spectroscopy

ENDOR (electron-nuclear

ENDOR resonance spectroscopy

Electron nuclear double resonance ENDOR) spectroscopy study

Electron-Nuclear Double

Electron-nuclear double resonance

Electron-nuclear double resonance ENDOR)

Electrons resonance spectroscopy

Nuclear ENDOR)

© 2024 chempedia.info