Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Effective loading capacity

Various other soft materials without the layer—lattice stmcture are used as soHd lubricants (58), eg, basic white lead or lead carbonate [598-63-0] used in thread compounds, lime [1305-78-8] as a carrier in wire drawing, talc [14807-96-6] and bentonite [1302-78-9] as fillers for grease for cable pulling, and zinc oxide [1314-13-2] in high load capacity greases. Graphite fluoride is effective as a thin-film lubricant up to 400°C and is especially useful with a suitable binder such as polyimide varnish (59). Boric acid has been shown to have promise as a self-replenishing soHd composite (60). [Pg.250]

The use of an extractant depends on loading capacity, extraction rate, pH range, and the cost of the reagent and the diluent. Loss of the extractant must be minimised because of its high cost. Organic losses to the aqueous phase are also undesirable because of the deleterious effect on cathode deposits. Advances in SX—EW processes are described in Reference 38. [Pg.207]

While protecting the compressor from surge is the most compelling control problem, it is not the only requirement. The compressor throughput must be adjusted to match its load. Capacity control interacts with surge protection, which reduces the effectiveness of the antisurge control system if they are not decoupled. [Pg.400]

Mach number, 26, IHO, 42 effect on axials, 23 L rotor tip, 100 Magnetic bearings, 204-8 air gap, 207 auxiliary bearing, 207 electromagnets, 205 laminated sleeve. 2U load capacity, 206 sensors, 206... [Pg.547]

The tensile load capacity of drill pipe corrected for the effect of the maximum allowable torque, according to Equation 4-58 is... [Pg.768]

Fig. 29—Effect of van der Waals force on loading capacity of a O type slider under different pitch angles. Input parameter was set as minimum film thickness ho=6 nm, roll angle =0, sliding speed u=25 m/s, length of the slider L=. 2S mm, width of the slider B = 1.1 mm, mass of the slider M=1.6 mg. Fig. 29—Effect of van der Waals force on loading capacity of a O type slider under different pitch angles. Input parameter was set as minimum film thickness ho=6 nm, roll angle <I>=0, sliding speed u=25 m/s, length of the slider L=. 2S mm, width of the slider B = 1.1 mm, mass of the slider M=1.6 mg.
Fig. 28—Effect of van der Waals force on loading capacities of simple inclined and two-rail sliders, d is the thickness of PFPE lubrication film on disk, (a) simple inclined slider (b) two-rail slider. Fig. 28—Effect of van der Waals force on loading capacities of simple inclined and two-rail sliders, d is the thickness of PFPE lubrication film on disk, (a) simple inclined slider (b) two-rail slider.
However, issues remain with sample loading capacity, and CapLC-NMR may be best suited to mass-limited samples where the component of interest is present at a sufficient concentration such that column loading does not become an issue [88]. Capillary probes have therefore been used most effectively where... [Pg.208]

Humic substances were concentrated more than 50-fold on the XAD-4 quaternary resin, but a saturated HCl/methanol solution was required for the desorption. This eluant was not concentrated further because the concentration of humic substances could be measured directly with a spectrophotometer. Total recovery of humic substances was higher in the bench-scale experiments than in the pilot plant studies. On the basis of the pilot plant results (see summary of experiment 3), it appears that the adsorption of humic substances was affected by the higher velocity or the loading capacity because 458 was recovered in the effluent water. The higher velocity in the pilot plant studies did not have a similar effect on other compounds such as quinaldic acid, for example, which was recovered at almost 100. It is believed that caffeine, which was concentrated during bench-scale studies, was also affected by the higher velocity in the pilot plant studies. [Pg.539]

Open tubular columns enable the chromatographer to effect separations impossible by other techniques, for example, separation of isomers. Their use permits a smaller inventory of columns and a smaller selection of stationary phases. Their main advantage is their high efficiency and their disadvantage is their small load capacity. [Pg.148]


See other pages where Effective loading capacity is mentioned: [Pg.590]    [Pg.202]    [Pg.590]    [Pg.202]    [Pg.144]    [Pg.175]    [Pg.84]    [Pg.111]    [Pg.79]    [Pg.187]    [Pg.141]    [Pg.171]    [Pg.291]    [Pg.20]    [Pg.180]    [Pg.239]    [Pg.76]    [Pg.364]    [Pg.313]    [Pg.204]    [Pg.340]    [Pg.58]    [Pg.200]    [Pg.145]    [Pg.47]    [Pg.48]    [Pg.50]    [Pg.486]    [Pg.581]    [Pg.198]    [Pg.251]    [Pg.147]    [Pg.267]    [Pg.261]    [Pg.15]    [Pg.132]    [Pg.145]    [Pg.106]    [Pg.56]    [Pg.505]    [Pg.509]    [Pg.15]   
See also in sourсe #XX -- [ Pg.590 ]




SEARCH



Loading capacities

Loading effect

© 2024 chempedia.info