Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Impact Drop test

The study on commercial HDPE samples could not provide a correlation of the izod impact test with the field performance test, i.e., drop impact resistance on moulded products [113]. It was found that the sample of highest density and lowest izod impact strength passed the drop impact test, but other samples of lower density and higher izod impact strength could not withstand shock loading by drop impact and failed in brittle manner. This may be due to the fact that velocities and modes of loading vary widely in different impact tests. It has been reported that even the qualitative agreement between the different impact tests is poor because the test bars and moulded products often have different orientation characteristics, particularly near the surface [115]. [Pg.288]

Laminae 4116 and Selectron 5003, were found to be satisfactory and interchangeable for use in these compns. These expls are thermally stable, relatively insensitive to mechanical shock, and have a brisance approaching that of Comp C-3. Weight-drop impact tests indicate them to be of the order of sensitivity of TNT... [Pg.211]

The flaw spectrum approach may be capable also of correlating failure data obtained under conditions which appear to give different material behavior. For example, tensile, Izod, and dart drop impact tests all give different impact energies or toughness measures. In part, this may be explained by the simple idea that a different fraction of flaws is active in each test. Equal biaxial loading (as in dart drop) and uniaxial tension (as in tensile impact) give rise to different flaw activities thus it is to be expected that the number of crazes produced in each test will be different. [Pg.42]

The EWF results were obtained for two HDPE grades at various test speeds. In addition to conventional EWF results, a special scaling analysis was performed to obtain CZM parameters. Some uncertainties due to the large scatter in measured separation distances were experienced, in particular at intermediate test speeds around 10 mm/s. However, the CZM data will only be used as the initial guess values in the numerical simulations of EWF tests. These simulations are designed for accurate calibration of the CZM parameters. Once the parameters are calibrated, they will be embedded in the predictive FSF model of the drop impact tests. [Pg.263]

Hydrogen Cycling, Bonfire, Severe Drop Impact Test, Flaw Tolerance, Acid Environment, Gunfire Penetration,... [Pg.8]

The dart drop impact test, ASTM D1709 and ASTM D4272, is often used for film samples. In D1709, a sample of the film is subjected to an impact by a round-... [Pg.87]

Figure 10.21 Effect of annealing on fracture crackle on PLA sheets after drop-impact testing without annealing (a) and with annealing (b). Reproduced with permission from Ref. Figure 10.21 Effect of annealing on fracture crackle on PLA sheets after drop-impact testing without annealing (a) and with annealing (b). Reproduced with permission from Ref.
The drop impact test is ideal for measuring impact resistance of materials or parts that will be used in a fashion in which they could either be hit with a sharp object (a hammer, for example) or dropped (a plastic container, for example). ASTM D2463 describes a drop impact test for a blow-molded container. [Pg.145]

The total energy absorbed in the drop impact test is shown in Fig. 13.2. The total energy absorbed has been normalized to 4.0 mm composite thickness to facilitate... [Pg.206]

Figure 9.12 Experimental setup for the jet or drop impact test. Figure 9.12 Experimental setup for the jet or drop impact test.
Geng and He performed also a water drop impact test on their superomniphobic surfaces [52]. In this test, about 4500 water droplets (ca. 22 mL) were dropped from a height of 50 cm above the coating. The velocity at which the water droplets impacted the surface was Im/s. The water and ethylene glycol APCAs remained xmchanged after the water-drop impact test. [Pg.237]

Drop impact test Impact resistance test in which the predetermined weight is allowed to fall freely onto the specimen from varying heights. The energy absorbed by the specimen is measured and expressed in in.-lb or ft-lb. [Pg.519]

Falling weight impact tester See Drop impact test. [Pg.519]


See other pages where Impact Drop test is mentioned: [Pg.288]    [Pg.7]    [Pg.110]    [Pg.41]    [Pg.259]    [Pg.261]    [Pg.255]    [Pg.203]    [Pg.128]    [Pg.175]    [Pg.2214]    [Pg.145]    [Pg.205]    [Pg.340]    [Pg.58]    [Pg.68]    [Pg.69]    [Pg.506]   
See also in sourсe #XX -- [ Pg.110 ]

See also in sourсe #XX -- [ Pg.145 ]

See also in sourсe #XX -- [ Pg.69 , Pg.519 ]




SEARCH



Impact testing

Test, testing impact

© 2024 chempedia.info